{"id":1307,"date":"2022-08-08T16:37:02","date_gmt":"2022-08-08T08:37:02","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?page_id=1307"},"modified":"2026-07-27T18:21:32","modified_gmt":"2026-07-27T10:21:32","slug":"valve-wall-thickness-testing","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/valve-wall-thickness-testing\/","title":{"rendered":"\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0633\u0645\u0643 \u062c\u062f\u0627\u0631 \u062c\u0633\u0645 \u0627\u0644\u0635\u0645\u0627\u0645"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1307\" class=\"elementor elementor-1307\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e49e3e69 e-con-full e-flex e-con e-parent\" data-id=\"e49e3e69\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5dc61bc elementor-widget elementor-widget-html\" data-id=\"c5dc61bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>:root{--rv-navy:#0b1731;--rv-navy2:#101f43;--rv-blue:#1f29bd;--rv-yellow:#f3cc18;--rv-ink:#16213a;--rv-line:#dce3ee}.rv-cat{font-family:Geologica,Arial,sans-serif;color:var(--rv-ink);font-size:16px;line-height:1.72;background:#fff;width:100vw;margin-left:calc(50% - 50vw)}.rv-cat *{box-sizing:border-box}.rv-wrap{width:min(1180px,calc(100% - 40px));margin:auto}.rv-section{padding:84px 0}.rv-kicker{font-size:12px;letter-spacing:.14em;text-transform:uppercase;font-weight:800;color:var(--rv-blue);margin:0 0 10px}.rv-title{font-size:clamp(34px,5vw,60px);line-height:1.08;margin:0 0 22px;color:#fff;max-width:900px}.rv-h2{font-size:clamp(28px,4vw,42px);line-height:1.16;margin:0 0 18px}.rv-lead{font-size:18px;max-width:820px;color:#526079;margin:0}.rv-hero{position:relative;isolation:isolate;background:linear-gradient(100deg,rgba(7,18,42,.98),rgba(13,32,74,.91) 60%,rgba(24,42,81,.74)),url('https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/07\/industrial-valve-body-inspection-rfq-workflow.webp') center\/cover no-repeat;padding:112px 0 96px;overflow:hidden}.rv-hero:after{content:\"\";position:absolute;z-index:-1;width:430px;height:430px;border:1px solid rgba(255,255,255,.12);border-radius:50%;right:-120px;top:-170px;box-shadow:0 0 0 80px rgba(255,255,255,.03),0 0 0 160px rgba(255,255,255,.02)}.rv-crumb{color:#b7c5e6;font-size:13px;margin-bottom:24px}.rv-crumb a{color:#fff;text-decoration:none}.rv-hero p{max-width:780px;color:#dbe5fa;font-size:18px;margin:0 0 30px}.rv-actions{display:flex;gap:12px;flex-wrap:wrap}.rv-btn{display:inline-flex;padding:13px 20px;border-radius:6px;text-decoration:none;font-weight:800;font-size:14px;border:1px solid transparent}.rv-primary{background:var(--rv-yellow);color:#111a31}.rv-ghost{border-color:#aebbd7;color:#fff}.rv-pills{display:flex;gap:10px;flex-wrap:wrap;margin-top:36px}.rv-pill{padding:8px 12px;border:1px solid rgba(255,255,255,.18);background:rgba(255,255,255,.06);border-radius:999px;color:#dce7ff;font-size:12px}.rv-intro{display:grid;grid-template-columns:.9fr 1.1fr;gap:54px;align-items:center}.rv-visual{background:linear-gradient(145deg,#eef3ff,#fff);border:1px solid var(--rv-line);border-radius:18px;padding:36px;min-height:360px;display:grid;place-items:center;position:relative}.rv-visual img{width:100%;max-height:300px;object-fit:contain}.rv-badge{position:absolute;left:18px;bottom:18px;background:var(--rv-navy);color:#fff;border-radius:9px;padding:12px 15px;font-size:12px}.rv-specgrid{display:grid;grid-template-columns:repeat(2,1fr);gap:0 26px}.rv-spec{padding:16px 0;border-bottom:1px solid var(--rv-line)}.rv-spec b{display:block;color:var(--rv-blue)}.rv-dark{background:linear-gradient(135deg,var(--rv-navy),var(--rv-navy2));color:#fff}.rv-dark .rv-h2{color:#fff}.rv-dark .rv-lead{color:#c8d5ef}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:18px;margin-top:38px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 10px 34px rgba(11,23,49,.07);position:relative;overflow:hidden}.rv-card:before{content:\"\";position:absolute;inset:0 0 auto;height:4px;background:linear-gradient(90deg,var(--rv-blue),#4c7cf5)}.rv-card h3{font-size:19px;line-height:1.3;margin:6px 0 10px}.rv-card p{font-size:14px;color:#5d6a81;margin:0}.rv-num{font-size:12px;color:var(--rv-blue);font-weight:800}.rv-dark .rv-card{background:rgba(255,255,255,.05);border-color:rgba(255,255,255,.14);box-shadow:none}.rv-dark .rv-card h3{color:#fff}.rv-dark .rv-card p{color:#c7d3eb}.rv-flow{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin-top:34px}.rv-step{border:1px solid var(--rv-line);border-radius:10px;padding:20px}.rv-step b{display:block;color:var(--rv-blue);margin-bottom:6px}.rv-step span{font-size:14px;color:#5d6a81}.rv-tablewrap{overflow:auto;border:1px solid var(--rv-line);border-radius:12px;margin-top:34px}.rv-table{width:100%;min-width:760px;border-collapse:collapse}.rv-table th{background:#edf2ff;text-align:left;padding:15px}.rv-table td{padding:15px;border-top:1px solid var(--rv-line);vertical-align:top}.rv-table td:first-child{font-weight:800;color:var(--rv-blue)}.rv-check{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin-top:34px}.rv-check div{border:1px solid rgba(255,255,255,.16);border-radius:10px;padding:16px 18px;color:#dce6f8}.rv-check div:before{content:\"\u2713\";display:inline-grid;place-items:center;width:22px;height:22px;border-radius:50%;background:var(--rv-yellow);color:#111;font-weight:900;margin-right:10px}.rv-faq{border-top:1px solid var(--rv-line);margin-top:30px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:20px 0}.rv-faq summary{cursor:pointer;font-weight:800;list-style:none}.rv-faq summary:after{content:\"+\";float:right;color:var(--rv-blue);font-size:22px}.rv-faq details[open] summary:after{content:\"\u2212\"}.rv-faq p{color:#5b687d;margin:12px 0 0}.rv-cta{background:linear-gradient(115deg,#121f40,#0a1530);border-radius:16px;padding:46px;display:flex;justify-content:space-between;gap:30px;align-items:center}.rv-cta h2{color:#fff;margin:0 0 8px;font-size:32px}.rv-cta p{color:#c9d5ec;margin:0;max-width:650px}.rv-note{font-size:12px;color:#7b879a;margin-top:18px}@media(max-width:980px){.rv-intro{grid-template-columns:1fr}.rv-grid,.rv-flow{grid-template-columns:repeat(2,1fr)}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1180px)}.rv-section{padding:58px 0}.rv-hero{padding:82px 0 66px}.rv-grid,.rv-flow,.rv-specgrid,.rv-check{grid-template-columns:1fr}.rv-cta{display:block;padding:30px 22px}.rv-cta .rv-actions{margin-top:22px}}.rv-topicgrid,.rv-routegrid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-topic,.rv-route{padding:22px;border:1px solid var(--rv-line);border-radius:12px;background:#fff}.rv-topic b,.rv-route b{display:block;color:var(--rv-blue);margin-bottom:7px}.rv-topic p,.rv-route p{margin:0;color:#667085;font-size:14px}.rv-limitgrid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-limit{padding:24px;border-radius:12px;background:#fff;color:#26344d}.rv-limit h3{margin:0 0 10px;color:#1f29bd;font-size:19px}.rv-limit p{margin:0;font-size:14px}.rv-trust{padding:26px;border:1px solid var(--rv-line);border-left:5px solid var(--rv-blue);border-radius:10px;background:#f8faff}.rv-trustgrid{display:grid;grid-template-columns:1fr 1fr;gap:18px 30px}.rv-trust b{display:block;color:var(--rv-ink);margin-bottom:5px}.rv-trust p{margin:0;color:#667085;font-size:14px}.rv-trustlinks{display:flex;flex-wrap:wrap;gap:10px;margin-top:18px}.rv-trustlinks a{color:var(--rv-blue);font-size:13px;font-weight:800}body.page-id-1307 #content,body.page-id-1307 .site-content,body.page-id-1307 #primary,body.page-id-1307 #main,body.page-id-1307 .entry-content{margin-top:0!important;padding-top:0!important}body.page-id-1307 .site-content>.ast-container{max-width:100%!important;padding-left:0!important;padding-right:0!important}@media(max-width:980px){.rv-topicgrid,.rv-routegrid,.rv-limitgrid{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-topicgrid,.rv-routegrid,.rv-limitgrid,.rv-trustgrid{grid-template-columns:1fr}}<\/style><main class=\"rv-cat\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/support\/\">Resources<\/a> \/ Valve Body Wall Thickness Verification<\/div><div class=\"rv-kicker\" style=\"color:#f3cc18\">Pressure-boundary geometry verified with context<\/div><h1 class=\"rv-title\">Valve Body Wall Thickness: Design Basis, Measurement and Acceptance<\/h1><p>Valve wall-thickness verification checks whether selected pressure-boundary locations conform to an approved design and manufacturing acceptance basis. A nominal catalog wall, a casting minimum, a design calculation and an ultrasonic reading are not interchangeable values. Complex body geometry, curved surfaces, transitions, machining allowances, corrosion allowance and measurement uncertainty all matter. The inspection plan should identify controlled drawings, critical zones, method, grid, calibration blocks and the disposition route for local readings below the stated criterion. Measurements should be taken after the manufacturing operations that establish the final pressure boundary whenever access permits. For replacement or in-service work, technicians should distinguish genuine metal loss from original casting profile, internal features and acoustic artifacts, while engineering retains responsibility for remaining-life or fitness-for-service decisions.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Technical Review<\/a><a class=\"rv-btn rv-ghost\" href=\"#technical-scope\">Open Technical Scope<\/a><\/div><div class=\"rv-pills\"><span class=\"rv-pill\">Approved design basis<\/span><span class=\"rv-pill\">Critical-section map<\/span><span class=\"rv-pill\">UT calibration<\/span><span class=\"rv-pill\">Local-thin-area disposition<\/span><\/div><\/div><\/section>\n<section id=\"technical-scope\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Technical scope<\/div><h2 class=\"rv-h2\">Connect every thickness reading to the pressure-boundary design<\/h2><div class=\"rv-topicgrid\"><div class=\"rv-topic\"><b>Design minimum<\/b><p>Use the approved calculation and drawing for the exact material, pressure-temperature case and geometry.<\/p><\/div><div class=\"rv-topic\"><b>Manufacturing minimum<\/b><p>Casting or forging allowances and local acceptance must be defined rather than inferred from nominal dimensions.<\/p><\/div><div class=\"rv-topic\"><b>Critical locations<\/b><p>Bodies, bonnets, necks, transitions, branch connections and machined cavities need a risk-based measurement map.<\/p><\/div><div class=\"rv-topic\"><b>Method capability<\/b><p>Ultrasonic access, probe size, curvature, surface roughness, coatings and internal geometry influence accuracy and interpretation.<\/p><\/div><div class=\"rv-topic\"><b>Corrosion context<\/b><p>For in-service valves, remaining thickness evaluation also needs original design, corrosion mechanism, rate and future service interval.<\/p><\/div><div class=\"rv-topic\"><b>Engineering disposition<\/b><p>A local low reading requires confirmation, mapping and responsible design review\u2014not grinding, blending or acceptance by verbal agreement.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Evidence matrix<\/div><h2 class=\"rv-h2\">Distinguish thickness values used in design and inspection<\/h2><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Thickness term<\/th><th>Purpose<\/th><th>Source of truth<\/th><th>Inspection implication<\/th><\/tr><\/thead><tbody><tr><td>Nominal drawing thickness<\/td><td>Defines the intended manufactured geometry before permitted variation.<\/td><td>Approved component or valve drawing and revision.<\/td><td>Do not use it automatically as the rejection limit without tolerances and minimum criteria.<\/td><\/tr><tr><td>Calculated required thickness<\/td><td>Supports pressure-boundary adequacy for defined design conditions and rules.<\/td><td>Approved design calculation linked to material and geometry.<\/td><td>Calculation assumptions, allowances and local stress features must be understood.<\/td><\/tr><tr><td>Specified minimum thickness<\/td><td>Provides an inspection acceptance threshold at defined locations.<\/td><td>Approved drawing, product standard or project engineering requirement.<\/td><td>Location and measurement method must correspond to where the minimum applies.<\/td><\/tr><tr><td>Machining allowance<\/td><td>Ensures final cavities, flanges, seats or joints retain required material after machining.<\/td><td>Manufacturing drawing and process plan.<\/td><td>Measurements before machining cannot prove final wall condition.<\/td><\/tr><tr><td>Corrosion\/erosion allowance<\/td><td>Adds intended service consumption where required by project philosophy.<\/td><td>Datasheet\/project design basis and calculation.<\/td><td>Remaining-life assessment cannot treat allowance as available without knowing actual history.<\/td><\/tr><tr><td>Measured remaining thickness<\/td><td>Records local current wall at an identified point and method.<\/td><td>Calibrated inspection report with location grid.<\/td><td>A reading requires uncertainty and coverage context before fitness-for-service conclusions.<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering evidence<\/div><h2 class=\"rv-h2\">Elements of a defensible thickness survey<\/h2><div class=\"rv-routegrid\"><div class=\"rv-route\"><b>Controlled drawing<\/b><p>Valve\/component identity and drawing revision define the geometry being checked.<\/p><\/div><div class=\"rv-route\"><b>Measurement grid<\/b><p>Annotated coordinates make readings repeatable and show coverage of transitions.<\/p><\/div><div class=\"rv-route\"><b>Calibration setup<\/b><p>Material velocity, reference block, probe and instrument range support valid UT data.<\/p><\/div><div class=\"rv-route\"><b>Surface condition<\/b><p>Coating, rough cast skin, curvature and couplant influence measurement quality.<\/p><\/div><div class=\"rv-route\"><b>Data review<\/b><p>Outliers are rescanned and mapped to determine local extent and likely geometry.<\/p><\/div><div class=\"rv-route\"><b>Disposition record<\/b><p>Design authority approves acceptance, repair, replacement or expanded examination.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Technical boundaries<\/div><h2 class=\"rv-h2\">Claims and shortcuts this page does not support<\/h2><div class=\"rv-limitgrid\"><div class=\"rv-limit\"><h3>Nominal wall is not always minimum acceptable wall<\/h3><p>The design and manufacturing documents must define tolerances, allowances and inspection criteria for each location.<\/p><\/div><div class=\"rv-limit\"><h3>A single ultrasonic spot cannot clear a complex casting<\/h3><p>Coverage must address transitions, locally machined areas and risk zones with a documented grid.<\/p><\/div><div class=\"rv-limit\"><h3>Thickness alone does not prove casting quality<\/h3><p>Surface\/subsurface defects, material properties, heat treatment and pressure testing remain separate controls.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Controlled workflow<\/div><h2 class=\"rv-h2\">From requirement to auditable evidence<\/h2><div class=\"rv-flow\"><div class=\"rv-step\"><b>1. Approve the design baseline<\/b><span>Collect calculations, drawings, material and required minimum locations.<\/span><\/div><div class=\"rv-step\"><b>2. Plan measurement coverage<\/b><span>Define grid, critical zones, access, final machining stage and acceptance values.<\/span><\/div><div class=\"rv-step\"><b>3. Qualify the method<\/b><span>Select instrument\/probe, reference standard, calibration and surface preparation.<\/span><\/div><div class=\"rv-step\"><b>4. Measure and map<\/b><span>Record individual values on a traceable component drawing, including uncertain locations.<\/span><\/div><div class=\"rv-step\"><b>5. Confirm low readings<\/b><span>Repeat, scan the surrounding area and check geometry or back-wall interference.<\/span><\/div><div class=\"rv-step\"><b>6. Obtain design disposition<\/b><span>Assess actual extent and document acceptance, repair or rejection before release.<\/span><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Project checklist<\/div><h2 class=\"rv-h2\">Information and records to define<\/h2><div class=\"rv-check\"><div>Valve\/component ID, material and drawing revision<\/div><div>Design pressure-temperature cases and calculation basis<\/div><div>Nominal, required and specified minimum thickness definitions<\/div><div>Machining and corrosion\/erosion allowances<\/div><div>Critical-location drawing and measurement grid<\/div><div>UT instrument, probe, calibration block and material velocity<\/div><div>Surface\/coating\/curvature condition and individual results<\/div><div>Low-reading confirmation, expanded mapping and approved disposition<\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Technical authority and scope<\/div><h2 class=\"rv-h2\">How this resource should be used<\/h2><div class=\"rv-trust\"><div class=\"rv-trustgrid\"><div><b>Primary search intent<\/b><p>Inspection and engineering guidance for new-manufacture or in-service valve wall-thickness verification, separating design minima from nominal and measured values.<\/p><\/div><div><b>Technical content owner<\/b><p>Raymon Valve technical content team. Final project decisions require the controlled documents and responsible engineer or quality reviewer.<\/p><\/div><div><b>Standards boundary<\/b><p>The applicable design\/product standard, approved calculation, component drawing, manufacturing tolerances and project inspection procedure govern. This page supplies no universal minimum wall values and is not a fitness-for-service assessment. Qualified design authority must evaluate any proposed repair or local-thin-area acceptance.<\/p><\/div><div><b>Review status<\/b><p>Technical scope reviewed 27 July 2026. Editions, procedures, acceptance criteria and product evidence must be reconfirmed before order.<\/p><\/div><\/div><div class=\"rv-trustlinks\"><a href=\"\/support\/\">Resource Center<\/a><a href=\"\/valve-standards\/\">Valve Standards<\/a><a href=\"\/valve-inspection\/\">Inspection &amp; Testing<\/a><a href=\"\/contact\/\">Request Technical Review<\/a><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Frequently asked questions<\/div><h2 class=\"rv-h2\">Valve Body Wall Thickness Verification FAQ<\/h2><div class=\"rv-faq\"><details><summary>How is valve body wall thickness measured?<\/summary><p>Ultrasonic thickness testing is common where surfaces and geometry permit; mechanical measurements may support accessible features. The method, calibration and location grid must suit the material and component.<\/p><\/details><details><summary>Is the catalog wall thickness the rejection limit?<\/summary><p>Not necessarily. Acceptance should come from the approved drawing, calculation and applicable manufacturing\/product requirements, including tolerances and allowances.<\/p><\/details><details><summary>What should happen after one low UT reading?<\/summary><p>Verify calibration and surface, repeat the reading, scan the surrounding area, check geometry\/back-wall effects and submit the mapped result for responsible engineering disposition.<\/p><\/details><details><summary>Does a pressure test prove adequate wall thickness?<\/summary><p>No. A pressure test verifies defined integrity under test conditions, but it does not replace design calculations, dimensional inspection or material and defect controls.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section\" style=\"padding-top:0\"><div class=\"rv-wrap\"><div class=\"rv-cta\"><div><div class=\"rv-kicker\" style=\"color:#f3cc18\">Technical evidence review<\/div><h2>Send the requirement and the evidence you need to verify<\/h2><p>We will identify the applicable scope, missing records and approval path without inventing compliance claims.<\/p><\/div><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Technical Review<\/a><\/div><\/div><\/div><\/section>\n<\/main><script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Resources\",\"item\":\"https:\/\/raymonvalve.com\/support\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Valve Body Wall Thickness Verification\",\"item\":\"https:\/\/raymonvalve.com\/valve-wall-thickness-testing\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is valve body wall thickness measured?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ultrasonic thickness testing is common where surfaces and geometry permit; mechanical measurements may support accessible features. The method, calibration and location grid must suit the material and component.\"}},{\"@type\":\"Question\",\"name\":\"Is the catalog wall thickness the rejection limit?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Not necessarily. Acceptance should come from the approved drawing, calculation and applicable manufacturing\/product requirements, including tolerances and allowances.\"}},{\"@type\":\"Question\",\"name\":\"What should happen after one low UT reading?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Verify calibration and surface, repeat the reading, scan the surrounding area, check geometry\/back-wall effects and submit the mapped result for responsible engineering disposition.\"}},{\"@type\":\"Question\",\"name\":\"Does a pressure test prove adequate wall thickness?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. A pressure test verifies defined integrity under test conditions, but it does not replace design calculations, dimensional inspection or material and defect controls.\"}}]}]<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Valve wall-thickness verification checks whether selected pressure-boundary locations conform to an approved design and manufacturing acceptance basis.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1307","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/1307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=1307"}],"version-history":[{"count":61,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/1307\/revisions"}],"predecessor-version":[{"id":13494,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/1307\/revisions\/13494"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=1307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}