{"id":13612,"date":"2026-07-27T22:01:11","date_gmt":"2026-07-27T14:01:11","guid":{"rendered":"https:\/\/raymonvalve.com\/data-center-cooling-valves\/"},"modified":"2026-07-27T22:38:18","modified_gmt":"2026-07-27T14:38:18","slug":"data-center-cooling-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/data-center-cooling-valves\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u062a\u0628\u0631\u064a\u062f \u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13612\" class=\"elementor elementor-13612 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23598c3f e-con-full e-flex e-con e-parent\" data-id=\"23598c3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38954e2f elementor-widget elementor-widget-html\" data-id=\"38954e2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ Data Center Cooling Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>Data Center Cooling Valves: Application and Selection Guide<\/h1><p>Data Center Cooling Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Start with the engineering decision, not a catalog label<\/h2><p class=\"rv-lead\">For data center cooling valves, the first review should cover design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method. The practical audience is application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system. Every recommendation remains conditional on the approved application and supplied records.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Chilled and hot water<\/b><p>Review the system condition and failure consequence, select a defensible route and retain evidence that applies to the actual valve tag.<\/p><\/div><div class=\"rv-card\"><b>02. Heat-exchanger isolation<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>03. Pump discharge and bypass<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>04. Building-management control loops<\/b><p>Treat this as an engineering decision with controlled inputs, stated assumptions, approved limits and a traceable closeout record.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Use this framework with the governing datasheet and project documents. It is not a substitute for tag-specific engineering approval.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Translate application data into a reviewable valve requirement<\/h2><p class=\"rv-lead\">A clear evidence route exposes scope gaps early and prevents a generic quotation from being mistaken for technical compliance.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>State the required action of data center cooling valves during normal operation, startup, trip, shutdown and loss of utility.<\/td><td>Controlled tag description, system narrative and cause-and-effect where relevant<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Quantify design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method and include every case that can control sizing, material or sealing.<\/td><td>Approved process cases, fluid-property source and assumptions register<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Confirm that the proposed valve physically and functionally fits the piping rather than matching only size and class.<\/td><td>Interface matrix covering ends, facing, bore, length, loads, clearance and orientation<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Map each wetted, load-bearing and sealing component to its environment, fabrication route and verification method.<\/td><td>Materials-selection record, drawing\/BOM, heat traceability and inspection results<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Use worst-case valve load and minimum utility to engineer the operator, controls, indication and safe response.<\/td><td>Torque\/thrust basis, actuator sizing, accessories list and package test procedure<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Agree design review, NDE, pressure and leakage tests, special qualifications, intervention points and final records.<\/td><td>Approved ITP, procedures, calibrated results and tag-linked manufacturing record book<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Failure modes to close before technical approval<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Hydraulic instability<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Water hammer<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Actuator and service access<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">How to move from open question to approved valve tag<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for data center cooling valves that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Quantify loads and performance limits instead of relying on nominal size, commercial labels or past habit.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Review drawings, calculations, materials, qualification scope and inspection plan against the controlled specification.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Confirm manufacturing and documentation closeout so the delivered valve can be identified, installed and maintained correctly.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">RFQ inputs that remove avoidable supplier assumptions<\/h2><p class=\"rv-lead\">Treat missing data as an open point. Silent assumptions can change materials, dimensions, actuator size, test scope, cost and lead time.<\/p><ul class=\"rv-check\"><li>Application scope frozen: Industry application for Data Center Cooling Valves<\/li><li>Tag identity, required action and safe state<\/li><li>Design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Pressure-temperature cases with differential pressure and duration where relevant<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Piping class, mating connection, bore, length, loads, access and removal clearance<\/li><li>Corrosion\/wear basis and the specified material for each pressure, wetted and sealing part<\/li><li>Actuator sizing cases, accessories, override, indication, interlocks and failure behavior<\/li><li>Document hierarchy, exact standard designations, editions and project supplements<\/li><li>ITP intervention points plus material, NDE, pressure, leakage and package tests<\/li><li>Required submittals, approval schedule, final records, preservation and commercial boundaries<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Website wording, a generic brochure or an unrelated certificate is not tag-level proof; use approved order documents and traceable manufacturing and test records.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Continue the review with product and quality pages<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/heavy-industry-valve-applications\/\">Heavy Industry<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/renewable-energy-valves\/\">Renewable Energy Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/shipbuilding-valves\/\">Shipbuilding Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Data Center Cooling Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Data Center Cooling Valves?<\/summary><p>Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Data Center Cooling Valves?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Evidence should mirror the risk and specification: approved design documents, traceable materials, controlled procedures, calibrated results, closed nonconformances and a searchable final index.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Give engineering enough information to challenge assumptions<\/h2><p>Provide the tag function, complete service envelope, installation, actuation and evidence scope so the response can address the actual project rather than a generic valve label.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Data Center Cooling Valves\",\"item\":\"https:\/\/raymonvalve.com\/data-center-cooling-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Data Center Cooling Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Data Center Cooling Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Evidence should mirror the risk and specification: approved design documents, traceable materials, controlled procedures, calibrated results, closed nonconformances and a searchable final index.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u0645\u0631\u0627\u062c\u0639\u0629 \u0635\u0645\u0627\u0645\u0627\u062a \u062a\u0628\u0631\u064a\u062f \u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a: \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0627\u0644\u0625\u0646\u0634\u0627\u0621\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a\u060c \u0648\u0645\u062f\u062e\u0644\u0627\u062a \u0637\u0644\u0628 \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13612","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13612"}],"version-history":[{"count":3,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13612\/revisions"}],"predecessor-version":[{"id":13897,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13612\/revisions\/13897"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}