{"id":13623,"date":"2026-07-27T22:02:32","date_gmt":"2026-07-27T14:02:32","guid":{"rendered":"https:\/\/raymonvalve.com\/district-heating-valves\/"},"modified":"2026-07-27T22:38:27","modified_gmt":"2026-07-27T14:38:27","slug":"district-heating-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/district-heating-valves\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0627\u0644\u0645\u0631\u0643\u0632\u064a\u0629"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13623\" class=\"elementor elementor-13623 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-202dc8a6 e-con-full e-flex e-con e-parent\" data-id=\"202dc8a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6fa62f5 elementor-widget elementor-widget-html\" data-id=\"d6fa62f5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ District Heating Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>District Heating Valves: Application and Selection Guide<\/h1><p>District Heating Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Turn the search question into controlled project inputs<\/h2><p class=\"rv-lead\">For district heating valves, the first review should cover design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method. The practical audience is application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system. Every recommendation remains conditional on the approved application and supplied records.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Chilled and hot water<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>02. Heat-exchanger isolation<\/b><p>Convert this subject into measurable requirements, review points and tag-linked evidence instead of leaving it as a brochure description.<\/p><\/div><div class=\"rv-card\"><b>03. Pump discharge and bypass<\/b><p>Treat this as an engineering decision with controlled inputs, stated assumptions, approved limits and a traceable closeout record.<\/p><\/div><div class=\"rv-card\"><b>04. Building-management control loops<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Service, jurisdiction, project specification and construction can change the result; verify current standards, calculations and supplier documents.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Connect every design choice to verifiable evidence<\/h2><p class=\"rv-lead\">Name the controlling question and the record that will close it so process, piping, mechanical, controls, quality and procurement work from one basis.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Define why the district heating valves tag exists, what failure looks like and which state protects the process.<\/td><td>P&ID, process narrative, tag criticality and approved shutdown philosophy<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Describe the medium and boundaries in enough detail to evaluate district heating valves without hidden service assumptions.<\/td><td>Process datasheet, composition, phase, contaminants and design envelope<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Confirm that the proposed valve physically and functionally fits the piping rather than matching only size and class.<\/td><td>Interface matrix covering ends, facing, bore, length, loads, clearance and orientation<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Define materials separately for the pressure boundary, trim, seats, stem\/shaft, packing, gaskets, bolting and protective layers.<\/td><td>Bill of materials, material certificates and approved corrosion or compatibility basis<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>State manual or automated duty, cycle rate, fail state, utility limits, travel time, feedback and interlocks.<\/td><td>Sizing calculation, control narrative, hook-up\/interface drawings and functional test<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Convert every critical requirement into a review, hold, witness or record point with stated acceptance.<\/td><td>Requirement-to-evidence matrix, inspection releases and final document index<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Application exposures to resolve before release<\/h2><p class=\"rv-lead\">Priority depends on the real operating case and consequence, but the following exposures deserve explicit review for this topic.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Hydraulic instability<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Water hammer<\/b><p>The proposal should explain the design safeguard, identify its limit and point to the order record that verifies it.<\/p><\/div><div class=\"rv-card\"><b>Actuator and service access<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">Stage-gated review for a defensible technical decision<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Establish the decision owner, scope boundary and success criteria for district heating valves.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Complete the hydraulic, torque\/thrust, rating, corrosion or transient checks that govern this duty.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Cross-check the supplier proposal with the datasheet, line class, project standards and risk register.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Release only the approved configuration and preserve its revision, inspections and final records in the tag dossier.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Build a comparable and auditable valve inquiry<\/h2><p class=\"rv-lead\">A disciplined inquiry improves technical comparability, reveals exclusions and reduces changes after purchase order placement.<\/p><ul class=\"rv-check\"><li>Application scope frozen: Industry application for District Heating Valves<\/li><li>Tag identity, required action and safe state<\/li><li>Design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Minimum\/normal\/maximum process cases and all design transients<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Mechanical interfaces, allowable loads, operator position and maintenance space<\/li><li>Corrosion\/wear basis and the specified material for each pressure, wetted and sealing part<\/li><li>Operator load, cycle frequency, speed, safe position, power\/air and control interfaces<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>Pressure, leakage, functional, NDE and special test acceptance criteria<\/li><li>Inspection points, document index, certificates, spares and delivery requirements<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Acceptance evidence must match the supplied configuration, tag, revision and agreed scope. Retain it in the final document index.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Follow the internal route from application to inspection<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/ballast-water-valves\/\">Ballast Water Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/municipal-water-valves\/\">Municipal Water Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/heavy-industry-valve-applications\/\">Heavy Industry<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about District Heating Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate District Heating Valves?<\/summary><p>Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for District Heating Valves?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Send the operating cases, not only a valve name<\/h2><p>Share fluid details, pressure-temperature and flow cases, piping interfaces, operation, standards, tests and documents. Raymon Valve can return a clarified route and open-point list.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"District Heating Valves\",\"item\":\"https:\/\/raymonvalve.com\/district-heating-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate District Heating Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for District Heating Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u0645\u0631\u0627\u062c\u0639\u0629 \u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0626\u0629 \u0627\u0644\u0645\u0631\u0643\u0632\u064a\u0629: \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0627\u0644\u0625\u0646\u0634\u0627\u0621\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a\u060c \u0648\u0645\u062f\u062e\u0644\u0627\u062a \u0637\u0644\u0628\u0627\u062a \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13623","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13623","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13623"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13623\/revisions"}],"predecessor-version":[{"id":13899,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13623\/revisions\/13899"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13623"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}