{"id":13653,"date":"2026-07-27T22:05:51","date_gmt":"2026-07-27T14:05:51","guid":{"rendered":"https:\/\/raymonvalve.com\/wastewater-valves\/"},"modified":"2026-07-27T22:40:19","modified_gmt":"2026-07-27T14:40:19","slug":"wastewater-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/wastewater-valves\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u0645\u0639\u0627\u0644\u062c\u0629 \u0645\u064a\u0627\u0647 \u0627\u0644\u0635\u0631\u0641 \u0627\u0644\u0635\u062d\u064a"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13653\" class=\"elementor elementor-13653 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b0f197d e-con-full e-flex e-con e-parent\" data-id=\"3b0f197d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a96227f elementor-widget elementor-widget-html\" data-id=\"8a96227f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ Wastewater Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>Wastewater Valves: Application and Selection Guide<\/h1><p>Wastewater Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Start with the engineering decision, not a catalog label<\/h2><p class=\"rv-lead\">For wastewater valves, the first review should cover water quality, solids content, hydraulic profile, pump transient and allowable head loss. For application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system, the goal is a defensible decision trail rather than an unsupported product claim.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Raw-water intake<\/b><p>Review the system condition and failure consequence, select a defensible route and retain evidence that applies to the actual valve tag.<\/p><\/div><div class=\"rv-card\"><b>02. Pump stations<\/b><p>Define what success means for this item, then connect the requirement to a drawing, calculation, inspection or functional result.<\/p><\/div><div class=\"rv-card\"><b>03. Treatment and chemical dosing<\/b><p>Review the system condition and failure consequence, select a defensible route and retain evidence that applies to the actual valve tag.<\/p><\/div><div class=\"rv-card\"><b>04. Distribution or discharge<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> The final valve requirement belongs to the project engineer and must be supported by the controlled edition of each standard and order document.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Connect every design choice to verifiable evidence<\/h2><p class=\"rv-lead\">Name the controlling question and the record that will close it so process, piping, mechanical, controls, quality and procurement work from one basis.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Define why the wastewater valves tag exists, what failure looks like and which state protects the process.<\/td><td>P&ID, process narrative, tag criticality and approved shutdown philosophy<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Describe the medium and boundaries in enough detail to evaluate wastewater valves without hidden service assumptions.<\/td><td>Process datasheet, composition, phase, contaminants and design envelope<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Freeze nominal size, rating route, bore, end details, orientation, loads, access and removable envelope.<\/td><td>Line class, piping arrangement, mating-interface schedule and approved general arrangement<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Coordinate operating frequency, speed, fail behavior, local override, signal and hazardous-area requirements.<\/td><td>Approved package datasheet, logic\/interface record and witnessed functional results where required<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Convert every critical requirement into a review, hold, witness or record point with stated acceptance.<\/td><td>Requirement-to-evidence matrix, inspection releases and final document index<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Application exposures to resolve before release<\/h2><p class=\"rv-lead\">These risks should appear in the supplier clarification and inspection plan rather than remain implied in a commercial description.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Surge and check-valve slam<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Coating and corrosion<\/b><p>Record the residual risk after design review and make the relevant drawing, procedure or test result part of the tag dossier.<\/p><\/div><div class=\"rv-card\"><b>Solids or biological fouling<\/b><p>The proposal should explain the design safeguard, identify its limit and point to the order record that verifies it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Technical approval should connect each important risk to construction, material, calculation, qualification and tag-level evidence.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">Six steps from application question to released order<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Establish the decision owner, scope boundary and success criteria for wastewater valves.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Build a controlled application-data set and flag every unknown that could change materials, sizing or operation.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Compare feasible valve families, constructions, materials and actuation routes before selecting a catalog model.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Quantify loads and performance limits instead of relying on nominal size, commercial labels or past habit.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Resolve deviations and verify interfaces, acceptance methods and evidence before manufacturing release.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Release only the approved configuration and preserve its revision, inspections and final records in the tag dossier.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Information to send for a meaningful technical response<\/h2><p class=\"rv-lead\">Treat missing data as an open point. Silent assumptions can change materials, dimensions, actuator size, test scope, cost and lead time.<\/p><ul class=\"rv-check\"><li>Review purpose and decision owner confirmed for Wastewater Valves<\/li><li>System boundary, operating role and criticality classification<\/li><li>Water quality, solids content, hydraulic profile, pump transient and allowable head loss<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Pressure-temperature cases with differential pressure and duration where relevant<\/li><li>Media constituents, concentration, phase behavior, impurities and cleaning exposure<\/li><li>Size, rating, ends, flow direction, orientation and installation envelope<\/li><li>Component-level materials map including welds, overlay, packing, gaskets and fasteners<\/li><li>Actuator sizing cases, accessories, override, indication, interlocks and failure behavior<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>ITP intervention points plus material, NDE, pressure, leakage and package tests<\/li><li>Required submittals, approval schedule, final records, preservation and commercial boundaries<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Website wording, a generic brochure or an unrelated certificate is not tag-level proof; use approved order documents and traceable manufacturing and test records.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Connect this decision with valve families and quality controls<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/lng-cryogenic-valves\/\">LNG & Cryogenic Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/cement-plant-valves\/\">Cement Plant Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/marine-valves\/\">Marine Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Wastewater Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Wastewater Valves?<\/summary><p>Provide water quality, solids content, hydraulic profile, pump transient and allowable head loss, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Wastewater Valves?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Give engineering enough information to challenge assumptions<\/h2><p>Provide the tag function, complete service envelope, installation, actuation and evidence scope so the response can address the actual project rather than a generic valve label.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Wastewater Valves\",\"item\":\"https:\/\/raymonvalve.com\/wastewater-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Wastewater Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide water quality, solids content, hydraulic profile, pump transient and allowable head loss, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Wastewater Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u0645\u0631\u0627\u062c\u0639\u0629 \u0635\u0645\u0627\u0645\u0627\u062a \u0645\u0639\u0627\u0644\u062c\u0629 \u0645\u064a\u0627\u0647 \u0627\u0644\u0635\u0631\u0641 \u0627\u0644\u0635\u062d\u064a: \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0627\u0644\u0625\u0646\u0634\u0627\u0621\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a\u060c \u0648\u0645\u062f\u062e\u0644\u0627\u062a \u0637\u0644\u0628 \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13653","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13653"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13653\/revisions"}],"predecessor-version":[{"id":13929,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13653\/revisions\/13929"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}