{"id":13681,"date":"2026-07-27T22:07:30","date_gmt":"2026-07-27T14:07:30","guid":{"rendered":"https:\/\/raymonvalve.com\/fire-safe-valve-standards\/"},"modified":"2026-07-27T22:45:54","modified_gmt":"2026-07-27T14:45:54","slug":"fire-safe-valve-standards","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/fire-safe-valve-standards\/","title":{"rendered":"\u0645\u0639\u0627\u064a\u064a\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0631\u064a\u0642"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13681\" class=\"elementor elementor-13681 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a5ace3b1 e-con-full e-flex e-con e-parent\" data-id=\"a5ace3b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5944a666 elementor-widget elementor-widget-html\" data-id=\"5944a666\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/knowledge-center\/\">Knowledge Center<\/a> \/ Fire Safe Standards<\/div><div class=\"rv-kicker\">Engineering resource<\/div><h1>Fire Safe Standards: Practical Engineering Guide<\/h1><p>This Fire Safe Standards resource is organized for a specific task: standards scope mapping. It shows which inputs to collect, how to review them and what evidence should remain in the procurement or maintenance record.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Turn the search question into controlled project inputs<\/h2><p class=\"rv-lead\">Standards are copyrighted and can change. Verify the official, licensed, project-approved edition before release. For engineers, inspectors and buyers seeking a task-focused valve reference with clear boundaries, the goal is a defensible decision trail rather than an unsupported product claim.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Exact designation and edition<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>02. Product and service applicability<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>03. Purchaser options and project supplements<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>04. Qualification or production evidence<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Use this framework with the governing datasheet and project documents. It is not a substitute for tag-specific engineering approval.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Build a requirement-to-evidence matrix for the tag<\/h2><p class=\"rv-lead\">A clear evidence route exposes scope gaps early and prevents a generic quotation from being mistaken for technical compliance.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Separate isolation, regulation, non-return and protective functions for fire safe standards; assign acceptance for each.<\/td><td>Datasheet function, line list and functional requirement approved by the responsible engineer<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Describe the medium and boundaries in enough detail to evaluate fire safe standards without hidden service assumptions.<\/td><td>Process datasheet, composition, phase, contaminants and design envelope<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Freeze nominal size, rating route, bore, end details, orientation, loads, access and removable envelope.<\/td><td>Line class, piping arrangement, mating-interface schedule and approved general arrangement<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Map each wetted, load-bearing and sealing component to its environment, fabrication route and verification method.<\/td><td>Materials-selection record, drawing\/BOM, heat traceability and inspection results<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Coordinate operating frequency, speed, fail behavior, local override, signal and hazardous-area requirements.<\/td><td>Approved package datasheet, logic\/interface record and witnessed functional results where required<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Define the supplier evidence needed to confirm material identity, manufacture, assembly and functional performance.<\/td><td>Controlled procedures, certificates, test reports, NCR closeout and turnover dossier<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Application exposures to resolve before release<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Using an uncontrolled or obsolete reference<\/b><p>The proposal should explain the design safeguard, identify its limit and point to the order record that verifies it.<\/p><\/div><div class=\"rv-card\"><b>Leaving assumptions undocumented<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Accepting evidence that is not linked to the valve tag<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Technical approval should connect each important risk to construction, material, calculation, qualification and tag-level evidence.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">How to move from open question to approved valve tag<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for fire safe standards that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially exact designation and edition.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Test the proposed route against every controlling case with documented methods and conservative assumptions.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Resolve deviations and verify interfaces, acceptance methods and evidence before manufacturing release.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Close deviations and retain tag-linked manufacturing, test, inspection and turnover evidence.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Information to send for a meaningful technical response<\/h2><p class=\"rv-lead\">A disciplined inquiry improves technical comparability, reveals exclusions and reduces changes after purchase order placement.<\/p><ul class=\"rv-check\"><li>Application scope frozen: Engineering resource for Fire Safe Standards<\/li><li>Tag, system function and consequence of failure<\/li><li>Exact designation and edition<\/li><li>Product and service applicability<\/li><li>Design envelope plus operating, startup, shutdown and upset cases<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Mechanical interfaces, allowable loads, operator position and maintenance space<\/li><li>Component-level materials map including welds, overlay, packing, gaskets and fasteners<\/li><li>Actuator sizing cases, accessories, override, indication, interlocks and failure behavior<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>ITP intervention points plus material, NDE, pressure, leakage and package tests<\/li><li>Required submittals, approval schedule, final records, preservation and commercial boundaries<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Acceptance evidence must match the supplied configuration, tag, revision and agreed scope. Retain it in the final document index.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Connect this decision with valve families and quality controls<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/knowledge-center\/\">Knowledge Center<small>Return to the knowledge center hub.<\/small><\/a><a class=\"rv-link\" href=\"\/fire-safe-valves\/\">Fire Safe Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/fire-protection-valves\/\">Fire Protection Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/iso-15848-low-emission-valves\/\">ISO 15848 Low Emission<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Fire Safe Standards<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Fire Safe Standards?<\/summary><p>Provide exact designation and edition, product and service applicability, purchaser options and project supplements, qualification or production evidence together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Fire Safe Standards?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>Initial guidance is possible, but a responsible recommendation requires the real process envelope, valve function and project requirements. Unknowns will be listed for closure.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Request a valve route tied to the real service<\/h2><p>Provide the tag function, complete service envelope, installation, actuation and evidence scope so the response can address the actual project rather than a generic valve label.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\/\/raymonvalve.com\/knowledge-center\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fire Safe Standards\",\"item\":\"https:\/\/raymonvalve.com\/fire-safe-valve-standards\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Fire Safe Standards?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide exact designation and edition, product and service applicability, purchaser options and project supplements, qualification or production evidence together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Fire Safe Standards?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial guidance is possible, but a responsible recommendation requires the real process envelope, valve function and project requirements. Unknowns will be listed for closure.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u0639\u0627\u064a\u064a\u0631 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062d\u0631\u064a\u0642: \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0627\u0644\u0625\u0646\u0634\u0627\u0621\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a\u060c \u0648\u0645\u062f\u062e\u0644\u0627\u062a \u0637\u0644\u0628\u0627\u062a \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13681","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13681"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13681\/revisions"}],"predecessor-version":[{"id":13988,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13681\/revisions\/13988"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}