{"id":13740,"date":"2026-07-27T22:10:58","date_gmt":"2026-07-27T14:10:58","guid":{"rendered":"https:\/\/raymonvalve.com\/pump-protection-valves\/"},"modified":"2026-07-27T22:45:34","modified_gmt":"2026-07-27T14:45:34","slug":"pump-protection-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ar\/pump-protection-valves\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0636\u062e\u0627\u062a"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13740\" class=\"elementor elementor-13740 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1322af35 e-con-full e-flex e-con e-parent\" data-id=\"1322af35\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf351ce9 elementor-widget elementor-widget-html\" data-id=\"bf351ce9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valve-solutions\/\">Solutions<\/a> \/ Pump Protection Valves<\/div><div class=\"rv-kicker\">Engineering solution<\/div><h1>Pump Protection Valves: Engineering Review Framework<\/h1><p>Pump Protection Valves requires a defined engineering problem, measurable acceptance criteria and traceable evidence. This page explains how Raymon Valve structures process-system valve selection, what project data controls the decision and which risks should be closed before manufacture or package release.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Define the application before choosing construction<\/h2><p class=\"rv-lead\">The search intent behind pump protection valves is practical: convert a process or procurement problem into an approved valve requirement and evidence plan. This page is written for engineers and buyers who need a defensible solution route rather than a generic product recommendation; it avoids universal suitability or certification claims that lack order evidence.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Define the functional objective<\/b><p>Record the governing data, open questions, owner of each interface and the verification activity needed before manufacture.<\/p><\/div><div class=\"rv-card\"><b>02. Freeze boundary conditions<\/b><p>Treat this as an engineering decision with controlled inputs, stated assumptions, approved limits and a traceable closeout record.<\/p><\/div><div class=\"rv-card\"><b>03. Compare feasible construction routes<\/b><p>Define what success means for this item, then connect the requirement to a drawing, calculation, inspection or functional result.<\/p><\/div><div class=\"rv-card\"><b>04. Verify package performance and records<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> The final valve requirement belongs to the project engineer and must be supported by the controlled edition of each standard and order document.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Connect every design choice to verifiable evidence<\/h2><p class=\"rv-lead\">A clear evidence route exposes scope gaps early and prevents a generic quotation from being mistaken for technical compliance.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>State the required action of pump protection valves during normal operation, startup, trip, shutdown and loss of utility.<\/td><td>Controlled tag description, system narrative and cause-and-effect where relevant<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Quantify system function and tag criticality and include every case that can control sizing, material or sealing.<\/td><td>Approved process cases, fluid-property source and assumptions register<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Freeze nominal size, rating route, bore, end details, orientation, loads, access and removable envelope.<\/td><td>Line class, piping arrangement, mating-interface schedule and approved general arrangement<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Define materials separately for the pressure boundary, trim, seats, stem\/shaft, packing, gaskets, bolting and protective layers.<\/td><td>Bill of materials, material certificates and approved corrosion or compatibility basis<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>State manual or automated duty, cycle rate, fail state, utility limits, travel time, feedback and interlocks.<\/td><td>Sizing calculation, control narrative, hook-up\/interface drawings and functional test<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Define the supplier evidence needed to confirm material identity, manufacture, assembly and functional performance.<\/td><td>Controlled procedures, certificates, test reports, NCR closeout and turnover dossier<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Failure modes to close before technical approval<\/h2><p class=\"rv-lead\">These risks should appear in the supplier clarification and inspection plan rather than remain implied in a commercial description.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Reusing one line-class valve for every duty<\/b><p>Close the exposure with project data, a technically reviewed supplier response and an objective inspection or performance criterion.<\/p><\/div><div class=\"rv-card\"><b>Separating valve selection from system dynamics<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><div class=\"rv-card\"><b>Omitting maintenance and operational constraints<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Technical approval should connect each important risk to construction, material, calculation, qualification and tag-level evidence.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">How to move from open question to approved valve tag<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for pump protection valves that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Build a controlled application-data set and flag every unknown that could change materials, sizing or operation.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Compare feasible valve families, constructions, materials and actuation routes before selecting a catalog model.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Test the proposed route against every controlling case with documented methods and conservative assumptions.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Cross-check the supplier proposal with the datasheet, line class, project standards and risk register.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Close deviations and retain tag-linked manufacturing, test, inspection and turnover evidence.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Build a comparable and auditable valve inquiry<\/h2><p class=\"rv-lead\">A disciplined inquiry improves technical comparability, reveals exclusions and reduces changes after purchase order placement.<\/p><ul class=\"rv-check\"><li>Review purpose and decision owner confirmed for Pump Protection Valves<\/li><li>System boundary, operating role and criticality classification<\/li><li>System function and tag criticality<\/li><li>Media and all operating cases<\/li><li>Pressure-temperature cases with differential pressure and duration where relevant<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Size, rating, ends, flow direction, orientation and installation envelope<\/li><li>Body, trim, seat, sealing, bolting, coating or lining materials<\/li><li>Actuator sizing cases, accessories, override, indication, interlocks and failure behavior<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>ITP intervention points plus material, NDE, pressure, leakage and package tests<\/li><li>Tag-linked record book, manuals, preservation, spares, logistics and handover date<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Marketing content can explain a route, but only controlled drawings, calculations, certificates, procedures and results can close an order requirement.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Connect this decision with valve families and quality controls<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valve-solutions\/\">Solutions<small>Return to the solutions hub.<\/small><\/a><a class=\"rv-link\" href=\"\/fire-protection-valves\/\">Fire Protection Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/pump-station-check-valves\/\">Pump Station Check Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/low-emission-valves\/\">Low Emission Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Pump Protection Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Pump Protection Valves?<\/summary><p>Provide system function and tag criticality, media and all operating cases, transient or shutdown behavior, inspection, testing and turnover evidence together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Pump Protection Valves?<\/summary><p>No universal type is best. The defensible choice is the one whose construction, materials, operator and evidence meet the complete application without relying on hidden assumptions.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Request a valve route tied to the real service<\/h2><p>Provide the tag function, complete service envelope, installation, actuation and evidence scope so the response can address the actual project rather than a generic valve label.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions\",\"item\":\"https:\/\/raymonvalve.com\/valve-solutions\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Pump Protection Valves\",\"item\":\"https:\/\/raymonvalve.com\/pump-protection-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Pump Protection Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide system function and tag criticality, media and all operating cases, transient or shutdown behavior, inspection, testing and turnover evidence together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Pump Protection Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No universal type is best. The defensible choice is the one whose construction, materials, operator and evidence meet the complete application without relying on hidden assumptions.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u0645\u0631\u0627\u062c\u0639\u0629 \u0635\u0645\u0627\u0645\u0627\u062a \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0636\u062e\u0627\u062a: \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062e\u062f\u0645\u0629\u060c \u0627\u0644\u0625\u0646\u0634\u0627\u0621\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a\u060c \u0648\u0645\u062f\u062e\u0644\u0627\u062a \u0637\u0644\u0628 \u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062e\u0627\u0635 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13740","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13740"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13740\/revisions"}],"predecessor-version":[{"id":13976,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/pages\/13740\/revisions\/13976"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}