{"id":13157,"date":"2026-06-02T16:22:22","date_gmt":"2026-06-02T08:22:22","guid":{"rendered":"https:\/\/raymonvalve.com\/?p=13157"},"modified":"2026-09-17T13:58:52","modified_gmt":"2026-09-17T05:58:52","slug":"industrial-ball-valve-applications","status":"publish","type":"post","link":"https:\/\/raymonvalve.com\/ar\/blog\/industrial-ball-valve-applications\/","title":{"rendered":"Industrial Ball Valve Applications: How Duty Changes Selection"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"13157\" class=\"elementor elementor-13157 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<article class=\"elementor-element elementor-element-d0db9308 e-con-full raymonvalve-blog-page rv-knowledge e-flex e-con e-parent\" data-id=\"d0db9308\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e2155283 elementor-widget elementor-widget-html\" data-id=\"e2155283\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n.raymonvalve-blog-page{--rv-navy:#10263a;--rv-teal:#066d77;--rv-orange:#b85a14;--rv-ink:#263746;--rv-muted:#566671;--rv-line:#d4dee4;--rv-soft:#f5f7f9;--rv-white:#fff;box-sizing:border-box;max-width:1140px;margin:0 auto;padding:24px 28px 72px;color:var(--rv-ink);font:400 18px\/1.72 \"Segoe UI\",Arial,sans-serif;overflow-wrap:anywhere}\n.raymonvalve-blog-page *{box-sizing:border-box}.raymonvalve-blog-page a{color:var(--rv-teal);text-decoration:underline;text-underline-offset:3px}.raymonvalve-blog-page a:hover,.raymonvalve-blog-page a:focus-visible{color:#8f430e}.raymonvalve-blog-page a:focus-visible,.raymonvalve-blog-page summary:focus-visible,.raymonvalve-blog-page [tabindex=\"0\"]:focus-visible{outline:3px solid #f0a45c;outline-offset:3px}.raymonvalve-blog-page p{margin:0 0 1.15em}.raymonvalve-blog-page h2,.raymonvalve-blog-page h3{color:var(--rv-navy);line-height:1.24;scroll-margin-top:110px}.raymonvalve-blog-page h2{margin:2.15em 0 .75em;font-size:clamp(1.65rem,3vw,2.25rem)}.raymonvalve-blog-page h3{margin:1.65em 0 .55em;font-size:clamp(1.22rem,2.2vw,1.52rem)}\n.raymonvalve-blog-page .raymonvalve-breadcrumb{margin:0 0 24px;font-size:15px;color:var(--rv-muted)}.raymonvalve-blog-page .raymonvalve-breadcrumb ol{display:flex;flex-wrap:wrap;gap:8px;margin:0;padding:0;list-style:none}.raymonvalve-blog-page .raymonvalve-breadcrumb li+li:before{content:\"\/\";margin-right:8px;color:#7d8d97}\n.raymonvalve-blog-page [data-master-slot=\"content\"]>p,.raymonvalve-blog-page [data-master-slot=\"content\"]>ul,.raymonvalve-blog-page [data-master-slot=\"content\"]>ol,.raymonvalve-blog-page [data-master-slot=\"content\"]>h2,.raymonvalve-blog-page [data-master-slot=\"content\"]>h3,.raymonvalve-blog-page .raymonvalve-lead,.raymonvalve-blog-page .raymonvalve-boundary{max-width:820px;margin-left:auto;margin-right:auto}\n.raymonvalve-blog-page .raymonvalve-lead{padding:30px;border-left:5px solid var(--rv-teal);border-radius:0 18px 18px 0;background:linear-gradient(135deg,#edf6f7,var(--rv-white));font-size:1.08em}.raymonvalve-blog-page .raymonvalve-lead p:last-child{margin-bottom:0}.raymonvalve-blog-page .raymonvalve-boundary{margin-top:30px;margin-bottom:30px;padding:22px 25px;border:1px solid #e0b887;border-left:5px solid var(--rv-orange);border-radius:14px;background:#fff8ef}.raymonvalve-blog-page .raymonvalve-boundary strong{display:block;margin-bottom:5px;color:#7d3a0c}.raymonvalve-blog-page .raymonvalve-boundary p{margin:0}\n.raymonvalve-blog-page .raymonvalve-toc{max-width:820px;margin:34px auto 44px;padding:24px 28px;border:1px solid var(--rv-line);border-radius:16px;background:var(--rv-soft)}.raymonvalve-blog-page .raymonvalve-toc h2{margin:0 0 14px;font-size:1.35rem}.raymonvalve-blog-page .raymonvalve-toc ol{columns:2;column-gap:36px;margin:0;padding-left:1.25em}.raymonvalve-blog-page .raymonvalve-toc li{break-inside:avoid;margin:.42em 0}.raymonvalve-blog-page .raymonvalve-toc a{text-decoration:none}\n.raymonvalve-blog-page .raymonvalve-media{margin:40px auto 48px;max-width:1000px}.raymonvalve-blog-page .raymonvalve-media img{display:block;width:100%;height:auto;border:1px solid var(--rv-line);border-radius:18px;background:var(--rv-soft);box-shadow:0 12px 30px rgba(16,38,58,.10)}.raymonvalve-blog-page .raymonvalve-media figcaption{max-width:900px;margin:12px auto 0;color:var(--rv-muted);font-size:15px;line-height:1.55;text-align:center}.raymonvalve-blog-page .raymonvalve-media--hero{max-width:1120px}\n.raymonvalve-blog-page ul,.raymonvalve-blog-page ol{margin:0 0 1.35em;padding-left:1.35em}.raymonvalve-blog-page li{margin:.36em 0}.raymonvalve-blog-page .raymonvalve-table-wrap{width:100%;margin:26px 0 36px;overflow-x:auto;border:1px solid var(--rv-line);border-radius:14px;background:var(--rv-white);box-shadow:0 6px 18px rgba(16,38,58,.06);-webkit-overflow-scrolling:touch}.raymonvalve-blog-page table{width:100%;min-width:760px;border-collapse:collapse;font-size:16px;line-height:1.5}.raymonvalve-blog-page th,.raymonvalve-blog-page td{padding:14px 16px;border-right:1px solid var(--rv-line);border-bottom:1px solid var(--rv-line);vertical-align:top;text-align:left}.raymonvalve-blog-page th{background:var(--rv-navy);color:var(--rv-white)}.raymonvalve-blog-page tbody tr:nth-child(even){background:#f8fafb}\n.raymonvalve-blog-page .raymonvalve-bid-normalization{margin:48px 0}.raymonvalve-blog-page .raymonvalve-cta{margin:58px 0;padding:34px;border-radius:22px;background:var(--rv-navy);color:var(--rv-white);box-shadow:0 16px 34px rgba(16,38,58,.18)}.raymonvalve-blog-page .raymonvalve-cta h2{margin-top:0;color:var(--rv-white)}.raymonvalve-blog-page .raymonvalve-cta .raymonvalve-button{display:inline-block;margin-top:8px;padding:13px 22px;border-radius:999px;background:var(--rv-orange);color:var(--rv-white);font-weight:700;text-decoration:none}\n.raymonvalve-blog-page .raymonvalve-faq{margin:58px 0;padding:20px 30px 30px;border:1px solid var(--rv-line);border-radius:22px;background:var(--rv-soft)}.raymonvalve-blog-page .raymonvalve-faq>h2{margin-top:.35em}.raymonvalve-blog-page .raymonvalve-faq details{margin:12px 0;border:1px solid var(--rv-line);border-radius:14px;background:var(--rv-white)}.raymonvalve-blog-page .raymonvalve-faq summary{position:relative;padding:18px 52px 18px 20px;color:var(--rv-navy);font-weight:700;line-height:1.4;cursor:pointer;list-style:none}.raymonvalve-blog-page .raymonvalve-faq summary::-webkit-details-marker{display:none}.raymonvalve-blog-page .raymonvalve-faq summary:after{content:\"+\";position:absolute;right:20px;top:50%;transform:translateY(-50%);font-size:26px;color:var(--rv-teal)}.raymonvalve-blog-page .raymonvalve-faq details[open] summary:after{content:\"\u2212\"}.raymonvalve-blog-page .raymonvalve-faq-answer{padding:0 20px 18px}.raymonvalve-blog-page .raymonvalve-faq-answer p{margin:0}\n.raymonvalve-blog-page .raymonvalve-engineering-note{max-width:900px;margin:52px auto 0;padding:28px 30px;border:1px solid #e0b887;border-left:5px solid var(--rv-orange);border-radius:16px;background:#fff8ef}.raymonvalve-blog-page .raymonvalve-engineering-note h2{margin-top:0}.raymonvalve-blog-page .raymonvalve-engineering-note li{margin:.65em 0}.raymonvalve-blog-page .raymonvalve-owner-links{margin:48px 0 0;padding:28px 32px;border-radius:18px;background:#edf4f6}.raymonvalve-blog-page .raymonvalve-owner-links h2{margin-top:0}\n@media(max-width:767px){.raymonvalve-blog-page{padding:18px 16px 52px;font-size:17px;line-height:1.66}.raymonvalve-blog-page .raymonvalve-lead,.raymonvalve-blog-page .raymonvalve-cta,.raymonvalve-blog-page .raymonvalve-faq,.raymonvalve-blog-page .raymonvalve-owner-links,.raymonvalve-blog-page .raymonvalve-toc,.raymonvalve-blog-page .raymonvalve-engineering-note{padding:22px 20px;border-radius:15px}.raymonvalve-blog-page .raymonvalve-toc ol{columns:1}.raymonvalve-blog-page h2{margin-top:1.8em}.raymonvalve-blog-page .raymonvalve-media{margin:30px 0 36px}.raymonvalve-blog-page .raymonvalve-media img{border-radius:12px}.raymonvalve-blog-page .raymonvalve-media figcaption{text-align:left}.raymonvalve-blog-page table{min-width:700px;font-size:15px}.raymonvalve-blog-page th,.raymonvalve-blog-page td{padding:12px}.raymonvalve-blog-page .raymonvalve-cta .raymonvalve-button{display:block;width:100%;white-space:normal;text-align:center}}\n.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>p,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>ul,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>ol,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>h2,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>h3,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>.raymonvalve-lead,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>.raymonvalve-boundary{max-width:820px;margin-left:auto;margin-right:auto}.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>.raymonvalve-owner-links,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>.raymonvalve-cta,.raymonvalve-blog-page .rv-reading>.elementor-element>.elementor-widget-container>.raymonvalve-engineering-note{max-width:920px;margin-left:auto;margin-right:auto}.raymonvalve-blog-page .rv-reading>.elementor-element+.elementor-element h2{border-top:1px solid var(--rv-line);padding-top:52px}<\/style>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e2d23f60 e-con-full rv-reading e-flex e-con e-parent\" data-id=\"e2d23f60\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6ce1c60 elementor-widget elementor-widget-html\" data-id=\"b6ce1c60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<div class=\"raymonvalve-lead\"><p>Industrial Ball Valves are commonly screened for isolation, shutdown, transfer, drain, vent and utility duties in oil and gas, chemical processing, water treatment and power plants. Industry name alone does not select the valve. Define the exact medium, pressure, temperature, differential pressure, solids, corrosion risk, shutoff requirement, operating frequency and installation conditions first. Then verify the ball support, bore, seat and sealing system, materials, cavity behavior, end connection, torque, actuation, tests and documents for the offered configuration.<\/p>\n<p>This application guide focuses on how industry duty changes engineering review, evidence and RFQ requirements. For a general comparison of Ball Valve types, materials and construction choices, use the <a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-selection-guide\/\">Ball Valve Selection Guide<\/a>.<\/p>\n<\/div>\n\n<aside class=\"raymonvalve-boundary\" data-master-slot=\"evidence-boundary\" aria-label=\"Engineering selection boundary\">\n  <strong>Engineering boundary<\/strong>\n  <p>This guide supports application screening and RFQ review. It does not approve a Raymon Valve model, service, material, rating, construction, torque, actuator, test, qualification or order configuration.<\/p>\n<\/aside>\n\n<nav class=\"raymonvalve-toc\" aria-labelledby=\"on-this-page\">\n  <h2 id=\"on-this-page\">On this page<\/h2>\n  <ol>\n    <li><a href=\"#quick-answer-screen-the-duty-before-choosing-the-ball-valve\">Quick duty screen<\/a><\/li>\n    <li><a href=\"#define-the-application-as-a-duty-not-an-industry-label\">Define the duty<\/a><\/li>\n    <li><a href=\"#oil-and-gas-ball-valve-applications\">Oil and gas<\/a><\/li>\n    <li><a href=\"#chemical-processing-applications\">Chemical processing<\/a><\/li>\n    <li><a href=\"#water-and-wastewater-applications\">Water and wastewater<\/a><\/li>\n    <li><a href=\"#power-plant-applications\">Power plants<\/a><\/li>\n    <li><a href=\"#translate-the-duty-into-ball-valve-construction-questions\">Construction questions<\/a><\/li>\n    <li><a href=\"#size-manual-or-automated-operation-from-controlled-torque-data\">Actuation evidence<\/a><\/li>\n    <li><a href=\"#separate-standards-tests-and-order-evidence\">Standards and evidence<\/a><\/li>\n    <li><a href=\"#build-an-auditable-industrial-ball-valve-rfq\">RFQ checklist<\/a><\/li>\n    <li><a href=\"#faq\">FAQ<\/a><\/li>\n  <\/ol>\n<\/nav>\n\n<p class=\"raymonvalve-boundary\" data-attachment-id=\"14355\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\"><strong>Featured illustration:<\/strong> Conceptual duty-to-review map only. It links application data, engineering questions and evidence holds; it is not a product drawing, supplied configuration, test record or service approval.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52fc6c60 elementor-widget elementor-widget-html\" data-id=\"52fc6c60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"quick-answer-screen-the-duty-before-choosing-the-ball-valve\">Quick Answer: Screen the Duty Before Choosing the Ball Valve<\/h2>\n\n<p>A common application identifies a review path, not a finished valve specification. Two valves with the same nominal size and pressure class can require different constructions because their media, temperature cases, shutoff consequences, solids, cycling and maintenance conditions are different.<\/p>\n\n<p>Use the following table before shortlisting a Ball Valve:<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Application duty<\/th>\n<th>Minimum inputs<\/th>\n<th>First Ball Valve questions<\/th>\n<th>Approval hold<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Pipeline or transfer isolation<\/td>\n<td>Medium and phase, pressure, temperature, maximum differential pressure, bore or pigging need, shutoff consequence<\/td>\n<td>Floating or trunnion? Full or reduced bore? Which ends? Are cavity or isolation functions specified?<\/td>\n<td>Hold if <code>oil and gas service<\/code>, line size and Class are the only inputs<\/td>\n<\/tr>\n<tr>\n<td>Process or chemical isolation<\/td>\n<td>Composition, concentration, temperature, cleaning fluid, corrosion risk, deposits or polymerization, external-leakage consequence<\/td>\n<td>Is the complete wetted and sealing package defined? Can fluid remain in the cavity?<\/td>\n<td>Hold if body material alone is treated as compatibility proof<\/td>\n<\/tr>\n<tr>\n<td>Water or utility isolation<\/td>\n<td>Water chemistry, pressure, temperature, surge risk, solids, external environment, cycling<\/td>\n<td>Is this clean water, dosing chemical or wastewater duty? What closure time and maintenance access are required?<\/td>\n<td>Hold if all water services are treated as equivalent<\/td>\n<\/tr>\n<tr>\n<td>Fuel or power auxiliary service<\/td>\n<td>Exact plant system, fluid and phase, pressure-temperature cases, cycling, shutdown role, leakage consequence<\/td>\n<td>What limits the seat and sealing system? Is manual or automated operation required? Which tests and documents apply?<\/td>\n<td>Hold if <code>power plant service<\/code> is used as a universal suitability statement<\/td>\n<\/tr>\n<tr>\n<td>Automated shutdown<\/td>\n<td>Maximum differential pressure and direction, travel time, fail action, utilities, operating demand and safety logic<\/td>\n<td>Is controlled valve torque available? Which sizing factor, mounting and accessories apply?<\/td>\n<td>Hold if the valve and actuator are selected separately without a package calculation<\/td>\n<\/tr>\n<tr>\n<td>Dirty, abrasive or high-temperature duty<\/td>\n<td>Solids or deposits, particle characteristics, temperature cases, thermal cycling, allowable leakage, flushing and maintenance plan<\/td>\n<td>Is a Ball Valve still appropriate? Which seat and surface system enters review? How does the duty affect torque?<\/td>\n<td>Hold if <code>metal seated<\/code> is treated as automatic approval<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>Three rules apply across all industrial Ball Valve applications:<\/p>\n\n<ol>\n<li>A standard Ball Valve is normally screened for on-off or isolation duty. Throttling and process-control duties require a separate design and sizing review.<\/li>\n<li>A common industry use does not prove that every Ball Valve construction is suitable.<\/li>\n<li>Approval should remain open until the exact offered configuration and its supporting documents match the project data.<\/li>\n<\/ol>\n\n<p>For the complete cross-functional selection sequence, use the <a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-selection-guide\/\">Ball Valve Selection Guide<\/a>. This article focuses specifically on how application duty changes the questions that buyers and engineers must ask.<\/p>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14356\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-duty-to-risk-gates.webp\" alt=\"Duty to risk screening gates for industrial Ball Valve applications\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Engineering decision aid: define duty, operating cases, failure consequence and evidence before shortlisting a Ball Valve. An unresolved gate remains on HOLD.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27e732f4 elementor-widget elementor-widget-html\" data-id=\"27e732f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"define-the-application-as-a-duty-not-an-industry-label\">Define the Application as a Duty, Not an Industry Label<\/h2>\n\n<p>Start by stating what the valve must do. Typical functions include process isolation, maintenance block, emergency shutdown, transfer, tank isolation, bypass, drain, vent, sampling and automated sequencing. The function affects the required shutoff direction, frequency of operation, acceptable leakage, operating speed and failure consequence.<\/p>\n\n<p>The application definition should record at least:<\/p>\n\n<ul>\n<li>medium, composition, concentration, phase, contaminants and cleaning or flushing fluids;<\/li>\n<li>normal, design and credible upset pressure and temperature;<\/li>\n<li>maximum differential pressure and its direction during opening, closing and shutoff;<\/li>\n<li>solids, abrasion, crystallization, polymerization, coking, fouling or cavity deposits;<\/li>\n<li>flow and velocity information, pressure-drop sensitivity, bore requirement and any cleaning or pigging need;<\/li>\n<li>required shutoff direction and acceptance criterion;<\/li>\n<li>operating frequency, required travel time and maintenance strategy;<\/li>\n<li>internal corrosion or erosion risk and the external site environment;<\/li>\n<li>installation orientation, available space and piping-interface requirements.<\/li>\n<\/ul>\n\n<p>The Ball Valve decision should remain open when the service includes undefined continuous throttling, flashing, cavitation, severe erosion, two-phase instability, sticky or crystallizing media, fibrous solids, or an unassessed hydraulic transient. Missing process data is not a reason to make a conservative-sounding product claim. It is a reason to identify an engineering hold point.<\/p>\n\n<h3 id=\"application-definition-sheet\">Application Definition Sheet<\/h3>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Field<\/th>\n<th>Project input<\/th>\n<th>Why it changes selection<\/th>\n<th>Status<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Valve function<\/td>\n<td>Isolation, shutdown, transfer, drain, vent or other<\/td>\n<td>Defines operating and failure requirements<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<tr>\n<td>Operating cases<\/td>\n<td>Normal, design, upset, cleaning and shutdown<\/td>\n<td>Prevents selection from one nominal condition<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<tr>\n<td>Medium<\/td>\n<td>Composition, concentration, phase, contaminants<\/td>\n<td>Controls material and sealing review<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<tr>\n<td>Differential pressure<\/td>\n<td>Value and direction during each operating state<\/td>\n<td>Affects seat load, torque and actuator sizing<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<tr>\n<td>Solids and deposits<\/td>\n<td>Type, size, concentration and behavior<\/td>\n<td>Affects seat damage, cavity retention and torque<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<tr>\n<td>Failure consequence<\/td>\n<td>Seat passing, external leakage, failure to move, rapid closure<\/td>\n<td>Defines testing, actuation and documentation depth<\/td>\n<td>Confirmed \/ Open<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14357\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-four-industry-map.webp\" alt=\"Four industry Ball Valve application map for oil and gas chemical water treatment and power plants\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Concept map only: each industry contains multiple duties, risks and hold points. The industry name does not specify the valve construction.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77228a59 elementor-widget elementor-widget-html\" data-id=\"77228a59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"oil-and-gas-ball-valve-applications\">Oil and Gas Ball Valve Applications<\/h2>\n\n<p>Oil and gas is not one service condition. Transmission pipelines, refinery process lines, terminals, tank farms, fuel systems and emergency-shutdown stations impose different requirements.<\/p>\n\n<h3 id=\"transmission-and-pipeline-isolation\">Transmission and Pipeline Isolation<\/h3>\n\n<p>Pipeline isolation may require review of bore geometry, pigging or inspection-tool passage, pressure and differential pressure, ball support, end connection, remote operation and access for maintenance. Full bore, trunnion support, welded ends or special cavity functions may enter the review, but none should be inherited from the phrase <code>pipeline Ball Valve<\/code> alone.<\/p>\n\n<p>Where a project specifies a pipeline-valve product standard, the buyer should confirm the exact standard, project-approved edition, product scope and required evidence for the offered valve. A product name or catalog heading is not proof of compliance or certification.<\/p>\n\n<h3 id=\"refinery-terminal-and-tank-farm-isolation\">Refinery, Terminal and Tank-Farm Isolation<\/h3>\n\n<p>Clean hydrocarbon transfer, fuel service, high-temperature process fluid, drain and vent duty, and utility service should be treated separately. The review may include external-leakage consequence, stem and body-joint sealing, thermal cases, operating frequency, shutdown philosophy and access for inspection.<\/p>\n\n<p>Fire type-testing, anti-static design and fugitive-emission qualification are separate project requirements. They must not be inferred from hydrocarbon service or from a visible valve feature. If any of these requirements apply, request the exact design description and evidence scope for the offered configuration.<\/p>\n\n<h3 id=\"gas-and-emergency-shutdown-duty\">Gas and Emergency-Shutdown Duty<\/h3>\n\n<p>For an automated shutdown valve, define:<\/p>\n\n<ul>\n<li>maximum differential pressure and direction during closure;<\/li>\n<li>required closing or opening time;<\/li>\n<li>fail position and utility failure case;<\/li>\n<li>operating frequency and test-stroke requirements;<\/li>\n<li>control signal, solenoid, position feedback and enclosure requirements;<\/li>\n<li>valve torque source, revision and service assumptions;<\/li>\n<li>project sizing factor and actuator supply conditions.<\/li>\n<\/ul>\n\n<p>No actuator size can be approved from nominal valve size and pressure class alone. A safety-function or SIL conclusion also falls outside a basic valve application review; it requires the complete safety function, certified data and responsible project assessment.<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Oil and gas location<\/th>\n<th>Main duty<\/th>\n<th>Required project inputs<\/th>\n<th>Approval hold<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Transmission pipeline<\/td>\n<td>Isolation or sectionalizing<\/td>\n<td>Bore\/pigging, pressure and dP, ends, operation, cavity requirements<\/td>\n<td>Generic pipeline label without exact design and evidence<\/td>\n<\/tr>\n<tr>\n<td>Terminal or tank farm<\/td>\n<td>Transfer and tank isolation<\/td>\n<td>Fluid, temperature, leakage consequence, cycling, fire\/emission requirements<\/td>\n<td>Hydrocarbon service treated as proof of special qualification<\/td>\n<\/tr>\n<tr>\n<td>Gas shutdown station<\/td>\n<td>Automated isolation<\/td>\n<td>Closing dP, travel time, fail action, utilities, torque and controls<\/td>\n<td>Valve and actuator offered without a package sizing record<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>The <a href=\"https:\/\/raymonvalve.com\/oil-and-gas-industries\/\">oil and gas valve applications<\/a> page owns the broader multi-valve industry context. The present guide only defines the Ball Valve screening boundary.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-366df8ae elementor-widget elementor-widget-html\" data-id=\"366df8ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"chemical-processing-applications\">Chemical Processing Applications<\/h2>\n\n<p>Chemical-service selection should begin with the complete fluid description. Chemical name alone may be insufficient; concentration, temperature, impurities, water content, phase, cleaning fluid and operating cycle can all change the material and sealing review.<\/p>\n\n<h3 id=\"qualify-every-wetted-and-sealing-component\">Qualify Every Wetted and Sealing Component<\/h3>\n\n<p>Review the body, end closures, ball, stem, seats, packing, body seals or gaskets, and any exposed bearings or springs. A stainless steel, duplex, alloy, lined, PTFE-based, PEEK or metal-seat label does not establish compatibility by itself. The exact component, material specification or compound, condition, geometry and service boundary are relevant.<\/p>\n\n<p>This is why a chemical compatibility review must extend beyond the body:<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Component or interface<\/th>\n<th>Required information<\/th>\n<th>Possible mechanism to review<\/th>\n<th>Evidence owner<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Body and end closures<\/td>\n<td>Exact material specification, condition and fluid exposure<\/td>\n<td>Corrosion, localized attack or environmental cracking<\/td>\n<td>Materials and project engineering<\/td>\n<\/tr>\n<tr>\n<td>Ball and stem<\/td>\n<td>Exact material, surface condition and load<\/td>\n<td>Corrosion, wear, galling or torque transmission<\/td>\n<td>Manufacturer and materials engineering<\/td>\n<\/tr>\n<tr>\n<td>Seat system<\/td>\n<td>Exact compound or surface system, pressure-temperature basis<\/td>\n<td>Swelling, extraction, creep, wear or chemical attack<\/td>\n<td>Manufacturer and process\/materials engineering<\/td>\n<\/tr>\n<tr>\n<td>Stem packing<\/td>\n<td>Exact packing system and external-leakage requirement<\/td>\n<td>Chemical attack, relaxation, permeation or cycling effects<\/td>\n<td>Manufacturer and quality<\/td>\n<\/tr>\n<tr>\n<td>Body seals or gaskets<\/td>\n<td>Exact material and joint design<\/td>\n<td>Chemical attack, compression loss or thermal cycling<\/td>\n<td>Manufacturer and materials engineering<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<h3 id=\"dosing-solvents-and-batch-operation\">Dosing, Solvents and Batch Operation<\/h3>\n\n<p>Dosing systems can combine low flow, frequent cycling and concentrated chemicals. Solvent service may raise questions about swelling, extraction, permeation and external leakage. Batch production can add cleaning fluids and repeated changes in temperature or composition. These conditions should be recorded rather than hidden under a broad <code>chemical service<\/code> description.<\/p>\n\n<h3 id=\"crystallizing-polymerizing-or-fouling-media\">Crystallizing, Polymerizing or Fouling Media<\/h3>\n\n<p>A Ball Valve cavity may retain fluid when the valve changes position. If the medium can crystallize, polymerize, cure or deposit solids, review cavity behavior, flushing or drain strategy, seat damage, breakaway torque and maintenance access. Selection should remain open when the process and manufacturer cannot support the proposed cavity and sealing arrangement.<\/p>\n\n<p>For component-level specification logic, see the <a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-materials\/\">Ball Valve Materials guide<\/a>.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08a7532 elementor-widget elementor-widget-html\" data-id=\"a08a7532\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"water-and-wastewater-applications\">Water and Wastewater Applications<\/h2>\n\n<p>Water-service Ball Valves may be used for utility isolation, pump isolation, treatment skids and distribution systems, but clean water, dosing chemicals, seawater and wastewater are not equivalent duties.<\/p>\n\n<h3 id=\"clean-water-and-utility-systems\">Clean Water and Utility Systems<\/h3>\n\n<p>Confirm pressure and temperature, water chemistry, disinfectants, external environment, coating requirements, cycling and maintenance strategy. End connection should be selected as a complete piping interface: flange facing and bolting, thread form and sealing method, or weld preparation and inspection requirements must match the system.<\/p>\n\n<h3 id=\"treatment-chemicals-and-dosing-skids\">Treatment Chemicals and Dosing Skids<\/h3>\n\n<p>Separate water duty from hypochlorite, coagulant, acid, alkali and cleaning duties. Record chemical concentration, temperature, soft-part compatibility, leakage consequence and flushing conditions. Oxygen, chlorine or strong-oxidizer service requires exact material, cleaning and project evidence; it cannot be approved from a generic material label.<\/p>\n\n<h3 id=\"wastewater-sludge-and-solids\">Wastewater, Sludge and Solids<\/h3>\n\n<p>For wastewater, record the type, size and concentration of solids, fibers, grit and deposits. Review cavity accumulation, seat cutting, operating torque, flushing and the maintenance interval. A standard soft-seated Ball Valve should not be assumed suitable, but a metal seat or severe-service label is not an automatic solution either. The actual duty may require a different Ball Valve construction or review of another valve family.<\/p>\n\n<h3 id=\"closure-speed-and-hydraulic-transients\">Closure Speed and Hydraulic Transients<\/h3>\n\n<p>Quarter-turn operation can close a flow path quickly. In systems sensitive to pressure surge, required closure time should be established through the system design or transient analysis. Do not claim water-hammer prevention or select a closing time from a generic rule.<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Water duty<\/th>\n<th>What changes<\/th>\n<th>Ball Valve review<\/th>\n<th>Hold point<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Clean utility water<\/td>\n<td>Chemistry, pressure, coating, cycling<\/td>\n<td>Materials, ends, operator and maintenance<\/td>\n<td>Water quality or interface remains undefined<\/td>\n<\/tr>\n<tr>\n<td>Chemical dosing<\/td>\n<td>Concentration, temperature, cleaning fluid, leakage consequence<\/td>\n<td>Complete wetted and sealing package<\/td>\n<td>Body material is the only compatibility check<\/td>\n<\/tr>\n<tr>\n<td>Wastewater or sludge<\/td>\n<td>Solids, fibers, grit, deposits, flushing<\/td>\n<td>Cavity, seat, torque and alternative-family review<\/td>\n<td>Duty is treated as clean water<\/td>\n<\/tr>\n<tr>\n<td>Surge-sensitive line<\/td>\n<td>Flow condition and transient consequence<\/td>\n<td>Closure profile and actuator\/control strategy<\/td>\n<td>Closing time is selected without analysis<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>The broader industry route is the <a href=\"https:\/\/raymonvalve.com\/water-treatment-valves\/\">Water Treatment Valves application guide<\/a>.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80abcf82 elementor-widget elementor-widget-html\" data-id=\"80abcf82\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"power-plant-applications\">Power Plant Applications<\/h2>\n\n<p>A power plant contains many different systems. Cooling water, service water, compressed air, chemical treatment, fuel gas, fuel oil, drains, vents and high-temperature lines should not share one generic Ball Valve specification.<\/p>\n\n<h3 id=\"auxiliary-water-air-and-treatment-systems\">Auxiliary Water, Air and Treatment Systems<\/h3>\n\n<p>Define the exact medium, pressure-temperature envelope, cleanliness, cycling and maintenance requirement for each system. A valve used on service water may require a different material and operating review from one used on a chemical-treatment skid or compressed-air line.<\/p>\n\n<h3 id=\"fuel-gas-and-fuel-oil-isolation\">Fuel Gas and Fuel Oil Isolation<\/h3>\n\n<p>Fuel duty requires a clear leakage consequence, shutdown role, pressure-temperature basis, stem and body-joint sealing review, actuation basis and project test requirements. Fire testing, fugitive-emission qualification and safety-function requirements are independent evidence items. One does not prove another.<\/p>\n\n<h3 id=\"high-temperature-or-steam-duty\">High-Temperature or Steam Duty<\/h3>\n\n<p>A standard Ball Valve is not automatically suitable for steam or high-temperature service. Define normal, design, upset and cleaning temperatures; pressure at each relevant temperature; duration and cycling; deposits; shutoff acceptance; and hot-condition torque. Then qualify the complete pressure boundary, seat, packing, body seals and operator.<\/p>\n\n<p>For deeper thermal-duty review, use the <a href=\"https:\/\/raymonvalve.com\/blog\/high-temperature-ball-valve\/\">High-Temperature Ball Valve guide<\/a>.<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Plant system<\/th>\n<th>Main questions<\/th>\n<th>Required evidence<\/th>\n<th>Hold trigger<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Cooling or service water<\/td>\n<td>Chemistry, pressure, coating, cycling, access<\/td>\n<td>Datasheet, materials and interface data<\/td>\n<td>Generic utility-service approval<\/td>\n<\/tr>\n<tr>\n<td>Chemical treatment<\/td>\n<td>Composition, concentration, cleaning and soft parts<\/td>\n<td>Complete component and compatibility review<\/td>\n<td>Body material alone<\/td>\n<\/tr>\n<tr>\n<td>Fuel gas or fuel oil<\/td>\n<td>Leakage consequence, shutdown, actuation, tests<\/td>\n<td>Torque\/package record and scoped qualification evidence<\/td>\n<td>Flammable service treated as proof of fire qualification<\/td>\n<\/tr>\n<tr>\n<td>High-temperature line<\/td>\n<td>Pressure at temperature, cycling, seals, hot torque<\/td>\n<td>Controlled rating, component limits and torque data<\/td>\n<td>Seat type or nominal Class used as full approval<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>The <a href=\"https:\/\/raymonvalve.com\/power-plants-industry\/\">Power Plant Valves application page<\/a> covers the wider multi-valve plant context.<\/p>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14354\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-construction-question-map.webp\" alt=\"Industrial Ball Valve construction questions for support bore sealing cavity connections and actuation\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Generic engineering map only. Actual construction, component materials, features and suitability require the offered-model drawing and controlled evidence.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ff9f693 elementor-widget elementor-widget-html\" data-id=\"0ff9f693\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"translate-the-duty-into-ball-valve-construction-questions\">Translate the Duty into Ball Valve Construction Questions<\/h2>\n\n<p>After defining the service, translate each risk into a construction question.<\/p>\n\n<h3 id=\"ball-support-and-body-construction\">Ball Support and Body Construction<\/h3>\n\n<p>Floating and trunnion-mounted designs use different ball-support and load paths. The appropriate route depends on the exact size, pressure, differential pressure, duty, offered design and torque basis. There is no universal industry, size or pressure cutoff that can replace manufacturer and project data.<\/p>\n\n<p>Side-entry, top-entry, one-piece, two-piece, three-piece and fully welded descriptions identify construction features. They may affect pressure-boundary joints, maintenance, installation and access, but no construction is inherently leak-free, maintenance-free or suitable for every application.<\/p>\n\n<h3 id=\"bore-and-flow-path\">Bore and Flow Path<\/h3>\n\n<p>Full or reduced bore affects geometry, velocity, pressure drop, cleaning and possible pigging requirements. Piggability, Cv\/Kv and pressure-drop conclusions require exact dimensions and, where necessary, calculation. They should not be inferred from a family description or image.<\/p>\n\n<h3 id=\"seat-and-complete-sealing-system\">Seat and Complete Sealing System<\/h3>\n\n<p>Review the seat, stem packing or seal, body-joint gasket or seal, and any secondary sealing components separately. Soft seat versus metal seat is a decision path, not an application shortcut. Exact material or compound, geometry, pressure-temperature and differential-pressure limits, medium, cycles and acceptance criteria must align.<\/p>\n\n<h3 id=\"cavity-and-isolation-features\">Cavity and Isolation Features<\/h3>\n\n<p>Cavity pressure relief, drain or vent, double block and bleed, double isolation and bleed, emergency sealant injection, anti-static devices and fire-tested designs are evidence-controlled features. If a project requires one, define the function and terminology, then request the exact drawing, pressure and direction basis, test scope and offered-model evidence.<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Service input<\/th>\n<th>Construction question<\/th>\n<th>Required evidence<\/th>\n<th>Do not infer<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>High dP or large operating load<\/td>\n<td>How is the ball supported and what torque applies?<\/td>\n<td>Exact design and controlled torque sheet<\/td>\n<td>Trunnion suitability from application name<\/td>\n<\/tr>\n<tr>\n<td>Pigging or low-resistance flow path<\/td>\n<td>What is the actual bore and geometry?<\/td>\n<td>Approved drawing and process requirement<\/td>\n<td>Full bore or piggability from catalog wording<\/td>\n<\/tr>\n<tr>\n<td>Corrosive or thermal duty<\/td>\n<td>What are all seat, packing and body-seal components?<\/td>\n<td>Component schedule and controlled limits<\/td>\n<td>Suitability from one material name<\/td>\n<\/tr>\n<tr>\n<td>Isolation or cavity requirement<\/td>\n<td>Which exact function and pressure direction are specified?<\/td>\n<td>Drawing, functional description and test evidence<\/td>\n<td>DBB, DIB or cavity relief from valve type<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51ac91c3 elementor-widget elementor-widget-html\" data-id=\"51ac91c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"review-materials-end-connections-and-pressure-temperature-separately\">Review Materials, End Connections and Pressure\u2013Temperature Separately<\/h2>\n\n<p>A complete material package identifies the body, end closures, ball, stem, seats, packing, body seals or gaskets, bolting, bearings, springs and any coatings or hardfacing. Each item should be tied to an exact component, specification or compound, product form or condition where relevant, and an operating boundary. Material family names do not guarantee corrosion resistance, abrasion life or special-service suitability.<\/p>\n\n<p>End connection is a separate piping-interface decision. For flanged, threaded, socket-weld or butt-weld ends, specify the mating standard, pipe dimensions, facing or thread form or weld preparation, gasket and bolting or welding and inspection requirements, and removal strategy. The <a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-end-connection-types\/\">Ball Valve End Connection Types guide<\/a> provides the detailed interface framework.<\/p>\n\n<p>Nominal Class or PN is also not a complete operating approval. The applicable design and pressure-temperature basis, exact material group, end connection and every seat or sealing limit should be checked against each credible operating case. The lowest applicable component or design boundary may control.<\/p>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14353\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-actuation-evidence-chain.webp\" alt=\"Ball Valve torque and actuator evidence chain from differential pressure to package approval\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Valve size does not select the actuator. Use configuration-specific torque, project sizing factor, utilities, fail action, travel time, interface and accessory evidence.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d2886d1 elementor-widget elementor-widget-html\" data-id=\"6d2886d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"size-manual-or-automated-operation-from-controlled-torque-data\">Size Manual or Automated Operation from Controlled Torque Data<\/h2>\n\n<p>Valve torque is not one universal number. The manufacturer may define break-to-open, running and end-to-close or reseat torque states. The applicable values depend on the exact configuration, maximum differential pressure and direction, seat and packing system, temperature, deposits, cycling assumptions and document revision.<\/p>\n\n<p>Manual lever or gearbox selection should consider controlled torque, operating frequency, access and project limits. Manual operability should not be promised from valve size or pressure class.<\/p>\n\n<p>Use the <a href=\"https:\/\/raymonvalve.com\/actuator-torque-review\/\">Actuator Torque Review guide<\/a> to organize the torque states, sizing basis, utilities, fail action and package records that require engineering confirmation.<\/p>\n\n<p>For an automated package, request:<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Input<\/th>\n<th>Required basis<\/th>\n<th>Supplier evidence<\/th>\n<th>Approval hold<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Valve torque<\/td>\n<td>Exact valve configuration, dP, direction, temperature and service assumptions<\/td>\n<td>Controlled torque sheet and revision<\/td>\n<td>Generic or ambient-only torque<\/td>\n<\/tr>\n<tr>\n<td>Sizing factor<\/td>\n<td>Project or approved package basis<\/td>\n<td>Actuator sizing calculation<\/td>\n<td>Unstated margin<\/td>\n<\/tr>\n<tr>\n<td>Utilities<\/td>\n<td>Minimum\/maximum air pressure or electrical supply<\/td>\n<td>Actuator data and project utility sheet<\/td>\n<td>Nominal supply only<\/td>\n<\/tr>\n<tr>\n<td>Fail action and travel time<\/td>\n<td>Process and safety requirement<\/td>\n<td>Package functional record<\/td>\n<td>Assumed fail position<\/td>\n<\/tr>\n<tr>\n<td>Controls and accessories<\/td>\n<td>Signal, solenoid, switches, positioner, protection<\/td>\n<td>Bill of materials and wiring\/pneumatic documents<\/td>\n<td>Visible actuator treated as complete scope<\/td>\n<\/tr>\n<tr>\n<td>Interface<\/td>\n<td>Mounting, coupling and orientation<\/td>\n<td>Assembly drawing<\/td>\n<td>Valve and actuator purchased without interface review<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>No final actuator size or included package can be stated until these fields are closed.<\/p>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14359\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-standards-evidence-scope.webp\" alt=\"Industrial Ball Valve standards and evidence scope map for design testing emissions and sour service\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Educational scope map: one standard, test or certificate cannot substitute for another requirement or prove every offered valve configuration.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3a887c1 elementor-widget elementor-widget-html\" data-id=\"b3a887c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"separate-standards-tests-and-order-evidence\">Separate Standards, Tests and Order Evidence<\/h2>\n\n<p>Standards should be assigned by role. A product design standard, pressure-shell\/rating reference, pressure-test standard, face-to-face standard, flange standard, fire-test standard, fugitive-emission qualification and sour-service material\/environment standard answer different questions.<\/p>\n\n<p>For example, <a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-34-valves-flanged-threaded-welding-end\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ASME B16.34<\/a> describes a scope that includes pressure-temperature ratings and other construction-related requirements for covered valves. It does not by itself establish chemical compatibility, seat limits or approval of a Raymon Valve configuration. The <a href=\"https:\/\/www.api.org\/products-and-services\/standards\/digital-catalog\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">API standards catalog<\/a> identifies product and testing publications, but project applicability and the exact offered-product evidence must still be confirmed.<\/p>\n\n<p>Similarly, a pressure and closure test does not prove fire-test qualification, external-emission performance, corrosion compatibility or service life. <a href=\"https:\/\/www.iso.org\/standard\/61441.html\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">ISO 15848-1<\/a> addresses a fugitive-emission type-testing and qualification scope for external leakage at stem or shaft seals and body joints; it does not establish seat shutoff. AMPP's <a href=\"https:\/\/www.ampp.org\/standards\/ampp-standards\/standards-resources\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">MR0175 \/ ISO 15156 resources<\/a> concern material and environmental restrictions in the defined H2S-containing oil and gas production scope; they do not establish a universal valve certification.<\/p>\n\n<p>The <a href=\"https:\/\/raymonvalve.com\/valve-pressure-testing\/\">Valve Pressure Testing guide<\/a> provides the internal review path for shell and closure test requirements while keeping fire, emission, material-environment and order-evidence scopes separate.<\/p>\n\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable technical table\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Requirement<\/th>\n<th>What the reference or evidence may address<\/th>\n<th>What it does not prove<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Design or pressure-rating basis<\/td>\n<td>Construction and rating requirements within scope<\/td>\n<td>Chemical compatibility, seat limits or exact product approval<\/td>\n<\/tr>\n<tr>\n<td>Pressure and closure test<\/td>\n<td>Pressure-boundary integrity and closure acceptance under defined test conditions<\/td>\n<td>Fire qualification, emissions, corrosion resistance or service life<\/td>\n<\/tr>\n<tr>\n<td>Fire type test<\/td>\n<td>Behavior of a covered tested design and configuration<\/td>\n<td>Every size, material, seat and operator variant<\/td>\n<\/tr>\n<tr>\n<td>Fugitive-emission qualification<\/td>\n<td>External stem or body-joint leakage within the valid scope<\/td>\n<td>Seat leakage or corrosion suitability<\/td>\n<\/tr>\n<tr>\n<td>Sour-service materials review<\/td>\n<td>Material and environment restrictions within the application scope<\/td>\n<td>Universal NACE compliance or product certification<\/td>\n<\/tr>\n<\/tbody><\/table><\/div>\n\n<p>For a quotation or technical bid, request controlled datasheets and drawings, component material schedules, pressure-temperature and seat-limit data, torque sheets, actuator sizing records, approved test and inspection procedures, applicable qualification evidence, material traceability, special-process records and a clear deviation schedule. Generic capability statements and blank templates are not order-specific evidence.<\/p>\n\n<p>Use the <a href=\"https:\/\/raymonvalve.com\/valve-inspection\/\">Quality &amp; Inspection process<\/a> to organize inspection planning, test records, traceability and document review without treating a generic capability page as order-specific evidence.<\/p>\n\n<figure class=\"raymonvalve-media\" data-image-status=\"live-verified\" data-attachment-id=\"14358\" data-evidence-role=\"non-evidentiary-engineering-illustration\" data-evidence-level=\"F0_UNVERIFIED\">\n  <img loading=\"lazy\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/08\/industrial-ball-valve-applications-rfq-checklist.webp\" alt=\"Industrial Ball Valve application RFQ checklist for service construction actuation tests documents and deviations\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" title=\"\">\n  <figcaption>Complete the service, construction, actuation, testing, document and deviation fields before comparing industrial Ball Valve quotations.<\/figcaption>\n<\/figure>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1267a10 elementor-widget elementor-widget-html\" data-id=\"c1267a10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"build-an-auditable-industrial-ball-valve-rfq\">Build an Auditable Industrial Ball Valve RFQ<\/h2>\n\n<p>An RFQ should allow suppliers to quote the same technical scope and identify deviations. Include:<\/p>\n\n<ul>\n<li>valve function, system location, quantity and tag requirements;<\/li>\n<li>DN\/NPS, pipe OD or schedule, PN\/Class and bore or pigging requirement;<\/li>\n<li>operating and design pressure and temperature, including credible upset and cleaning cases;<\/li>\n<li>maximum differential pressure and direction during operation and shutoff;<\/li>\n<li>medium, composition, concentration, phase, contaminants, solids and cleaning fluids;<\/li>\n<li>corrosion, erosion, deposit, cycling, surge and external-environment conditions;<\/li>\n<li>body, ball, stem, seat, packing, body seal or gasket, bolting and coating requirements;<\/li>\n<li>end connection and governing mating-interface requirements;<\/li>\n<li>shutoff direction, allowable leakage and operating frequency;<\/li>\n<li>manual, gear or actuated operation and required torque data;<\/li>\n<li>actuator utilities, sizing factor, fail action, travel time, signal, protection and accessories;<\/li>\n<li>applicable project standards and editions, tests, inspection, witness points and documents;<\/li>\n<li>material traceability, tagging, preservation, packing, destination and deviation schedule.<\/li>\n<\/ul>\n\n<p>Mark every critical field as <code>Confirmed<\/code>, <code>Project Option<\/code>, <code>Open<\/code>, <code>Not Applicable<\/code> or <code>Deviation<\/code>. An open critical field should remain visible during supplier comparison instead of being filled with an assumption.<\/p>\n\n<section class=\"raymonvalve-bid-normalization\" aria-labelledby=\"normalize-supplier-technical-bids-before-commercial-comparison\">\n<h2 id=\"normalize-supplier-technical-bids-before-commercial-comparison\">Normalize Supplier Technical Bids Before Commercial Comparison<\/h2>\n<p>Compare suppliers against the same confirmed duty and evidence fields. Do not normalize a deviation by silently assuming equivalence.<\/p>\n<div class=\"raymonvalve-table-wrap\" role=\"region\" aria-label=\"Scrollable supplier technical bid normalization table\" tabindex=\"0\"><table>\n<thead><tr><th>Review line<\/th><th>Supplier response required<\/th><th>Normalize and compare<\/th><th>HOLD or deviation trigger<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Offered valve entity<\/td><td>Model, construction, size, Class\/PN, bore and end connection<\/td><td>Confirm every bid refers to one identifiable offered configuration<\/td><td>Catalog family only, mixed models or missing drawing revision<\/td><\/tr>\n<tr><td>Pressure-temperature and sealing basis<\/td><td>Rating basis plus seat, packing and body-seal limits for every operating case<\/td><td>Compare the controlling limit and stated assumptions<\/td><td>One nominal Class\/PN or ambient data used as complete approval<\/td><\/tr>\n<tr><td>Materials and surfaces<\/td><td>Component-by-component material\/compound schedule, condition, coating or hardfacing<\/td><td>Compare the same component scope, not body material alone<\/td><td>Substitution, generic trim or missing soft-part identity<\/td><\/tr>\n<tr><td>Torque and operation<\/td><td>Configuration-specific torque revision and manual or actuator sizing record<\/td><td>Compare worst-case dP, factor, utilities, fail action and travel time<\/td><td>Generic torque, unknown supply or assumed fail action<\/td><\/tr>\n<tr><td>Tests and qualification<\/td><td>Applicable procedure, acceptance basis and configuration-linked evidence<\/td><td>Separate pressure, closure, fire, emissions and material-environment scopes<\/td><td>One test or certificate presented as proof of unrelated requirements<\/td><\/tr>\n<tr><td>Documents and deviations<\/td><td>Drawing, datasheet, material records, ITP, document index and explicit deviation list<\/td><td>Compare inclusions, exclusions, witness points and delivery records<\/td><td>Blank templates, capability brochure or unlisted exception<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Record each line as <strong>Comply<\/strong>, <strong>Project Option<\/strong>, <strong>Open<\/strong>, <strong>Not Applicable<\/strong> or <strong>Deviation<\/strong>. Commercial comparison should not close an engineering HOLD.<\/p>\n<\/section>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b055416 elementor-widget elementor-widget-html\" data-id=\"4b055416\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<h2 id=\"application-review-scenarios-not-customer-case-studies\">Application Review Scenarios \u2014 Not Customer Case Studies<\/h2>\n\n<p>The following hypothetical scenarios show how to use the framework. They are not Raymon Valve project records.<\/p>\n\n<h3 id=\"scenario-1-gas-pipeline-with-pigging-and-remote-shutdown\">Scenario 1: Gas Pipeline with Pigging and Remote Shutdown<\/h3>\n\n<p>Assume the line requires pig passage and remote isolation. The review must close the exact bore and geometry, support concept, maximum closing differential pressure, torque revision, actuator factor, supply condition, closure time, fail action and any cavity or isolation definition.<\/p>\n\n<p><strong>What remains open:<\/strong> the exact valve construction, product-standard applicability, special features and actuator size until controlled project and manufacturer data are available.<\/p>\n\n<h3 id=\"scenario-2-chemical-dosing-line-with-incomplete-composition-data\">Scenario 2: Chemical Dosing Line with Incomplete Composition Data<\/h3>\n\n<p>Assume the RFQ states only the chemical name and body material. Concentration, temperature, cleaning fluid, seat compound, packing and gasket are missing. The quotation cannot establish compatibility from the body material alone.<\/p>\n\n<p><strong>What remains open:<\/strong> the complete material and sealing package until process and compatibility data are confirmed.<\/p>\n\n<h3 id=\"scenario-3-wastewater-line-with-fibers-and-grit\">Scenario 3: Wastewater Line with Fibers and Grit<\/h3>\n\n<p>Assume the line contains variable solids and requires frequent isolation. Review cavity retention, seat damage, flushing, breakaway torque, cycling and maintenance. A different Ball Valve construction or another valve family may need assessment.<\/p>\n\n<p><strong>What remains open:<\/strong> whether a Ball Valve is the correct family and which design can be supported by the actual solids and operating data.<\/p>\n\n<h3 id=\"scenario-4-power-auxiliary-line-with-a-high-temperature-upset\">Scenario 4: Power Auxiliary Line with a High-Temperature Upset<\/h3>\n\n<p>Assume normal temperature is moderate but a credible upset is substantially hotter. Approval must include pressure at the upset temperature, duration, cycling, complete sealing-system limits, hot-condition torque and relevant testing or documentation.<\/p>\n\n<p><strong>What remains open:<\/strong> pressure-temperature suitability, seat and seal selection, torque and operator until the full thermal case and controlled component data are reconciled.<\/p>\n\n<section class=\"raymonvalve-cta\" data-master-slot=\"owner-links\" aria-labelledby=\"request-an-industrial-ball-valve-application-review\">\n<h2 id=\"request-an-industrial-ball-valve-application-review\">Request an Industrial Ball Valve Application Review<\/h2>\n<p>Send the valve function, medium and composition, operating and design pressure and temperature, maximum differential pressure, DN\/NPS, Class\/PN, bore requirement, materials, end connection, shutoff criterion, operating frequency, actuation requirements, required tests and project documents.<\/p>\n<p>Use the enquiry to request a review of whether the submitted application data and proposed configuration are complete and internally consistent. Final process, materials, piping, safety and project acceptance remain with the responsible project parties.<\/p>\n<p><a class=\"raymonvalve-button\" href=\"https:\/\/raymonvalve.com\/contact\/\">Request Valve Selection Review<\/a><\/p>\n<\/section>\n\n<section class=\"raymonvalve-faq\" aria-labelledby=\"faq\">\n<h2 id=\"faq\">FAQ<\/h2>\n<details open>\n  <summary id=\"what-are-the-main-industrial-ball-valve-applications\">What are the main industrial Ball Valve applications?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Ball Valves are commonly screened for isolation, transfer, shutdown, tank isolation, pump isolation, drain, vent and utility duties in oil and gas, chemical processing, water treatment, power generation and other process industries. Each duty still requires project-specific selection.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"are-ball-valves-mainly-used-for-isolation-or-throttling\">Are Ball Valves mainly used for isolation or throttling?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Standard Ball Valves are normally screened for fully open or fully closed isolation. Continuous throttling can create different velocity, pressure-drop, erosion and seat-loading conditions. A V-port or control-style design requires process data, sizing and controlled product evidence.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"what-data-is-needed-for-an-oil-and-gas-ball-valve\">What data is needed for an oil and gas Ball Valve?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Provide the exact service location and function, medium and phase, pressure and temperature cases, maximum differential pressure, bore or pigging requirement, shutoff consequence, end connection, operation method and any project-specific fire-test, emission, sour-service, testing or document requirements.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"how-should-a-ball-valve-be-reviewed-for-chemical-service\">How should a Ball Valve be reviewed for chemical service?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Confirm chemical identity, concentration, temperature, phase, contaminants and cleaning fluids. Review every wetted and sealing component, including the body, ball, stem, seat, packing and body seals or gaskets. A body-material label alone is insufficient.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"can-the-same-ball-valve-be-used-for-clean-water-and-wastewater\">Can the same Ball Valve be used for clean water and wastewater?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Not automatically. Wastewater may contain grit, fibers, sludge or deposits that affect the cavity, seat and operating torque. Clean water, dosing chemicals, seawater and wastewater should be treated as separate duties.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"are-ball-valves-suitable-for-steam-or-high-temperature-power-plant-service\">Are Ball Valves suitable for steam or high-temperature power-plant service?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Some Ball Valve designs may be reviewed for defined thermal duties, but a standard Ball Valve is not automatically suitable. Pressure at temperature, duration, cycling, complete sealing-system limits, allowable leakage and hot-condition torque must be verified.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"when-should-floating-versus-trunnion-construction-be-reviewed\">When should floating versus trunnion construction be reviewed?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Review the support concept using the exact valve size, pressure, maximum differential pressure, duty, offered design and torque basis. Do not apply one universal size or pressure cutoff.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"does-a-metal-seat-automatically-make-a-ball-valve-suitable-for-severe-service\">Does a metal seat automatically make a Ball Valve suitable for severe service?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>No. <code>Metal seated<\/code> does not define the base materials, loading, coating or hardfacing, contact geometry, leakage acceptance, operating torque or qualification. The complete seat system and service conditions require review.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"what-information-is-required-to-size-a-ball-valve-actuator\">What information is required to size a Ball Valve actuator?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Use controlled valve torque for the exact configuration and worst operating differential pressure, together with the required sizing factor, supply conditions, fail action, travel time, duty, mounting and accessory scope. Nominal size and Class are not sufficient.<\/p><\/div>\n<\/details>\n<details>\n  <summary id=\"which-documents-should-be-requested-with-an-industrial-ball-valve-quotation\">Which documents should be requested with an industrial Ball Valve quotation?<\/summary>\n  <div class=\"raymonvalve-faq-answer\"><p>Request the controlled datasheet and drawing, component material schedule, pressure-temperature and seat-limit basis, torque sheet, actuator sizing record where applicable, test and inspection documents, traceability requirements, qualification scope, order document index and deviation schedule.<\/p><\/div>\n<\/details>\n<\/section>\n\n<aside class=\"raymonvalve-engineering-note\" data-master-slot=\"evidence-boundary\" aria-labelledby=\"engineering-note\">\n<h2 id=\"engineering-note\">Engineering Note<\/h2>\n<ul>\n<li><strong>Purpose:<\/strong> preliminary industrial Ball Valve application screening, RFQ preparation and supplier-response normalization.<\/li>\n<li><strong>Assumptions and limits:<\/strong> no model, size, rating, material, pressure-temperature limit, torque, leakage, test, qualification or order statement is accepted unless it is tied to the exact offered configuration and controlled evidence.<\/li>\n<li><strong>Project confirmation:<\/strong> responsible process, materials, piping, automation, quality and safety parties must confirm the final selection and acceptance criteria.<\/li>\n<li><strong>Editorial owner:<\/strong> Raymon Valve Technical Content Team. No individual professional credential or personal project authorship is claimed.<\/li>\n<\/ul>\n<\/aside>\n  \n<aside class=\"raymonvalve-owner-links\" data-master-slot=\"owner-links\" aria-labelledby=\"related-engineering-resources\">\n  <h2 id=\"related-engineering-resources\">Related engineering resources<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/raymonvalve.com\/ball-valves\/\">Industrial Ball Valve range<\/a><\/li>\n    <li><a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-selection-guide\/\">Complete Ball Valve selection guide<\/a><\/li>\n    <li><a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-materials\/\">Ball Valve materials guide<\/a><\/li>\n    <li><a href=\"https:\/\/raymonvalve.com\/blog\/ball-valve-end-connection-types\/\">Ball Valve end connection guide<\/a><\/li>\n    <li><a href=\"https:\/\/raymonvalve.com\/blog\/high-temperature-ball-valve\/\">High-temperature Ball Valve guide<\/a><\/li>\n    <li><a href=\"https:\/\/raymonvalve.com\/contact\/\">Submit application data for review<\/a><\/li>\n  <\/ul>\n<\/aside>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Learn how oil and gas, chemical, water and power duties change Ball Valve design, materials, actuation, testing and RFQ requirements.<\/p>","protected":false},"author":1,"featured_media":14355,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-13157","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/posts\/13157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=13157"}],"version-history":[{"count":9,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/posts\/13157\/revisions"}],"predecessor-version":[{"id":14692,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/posts\/13157\/revisions\/14692"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media\/14355"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=13157"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/categories?post=13157"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/tags?post=13157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}