{"id":10857,"date":"2022-12-16T10:48:16","date_gmt":"2022-12-16T02:48:16","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?post_type=product&#038;p=10857"},"modified":"2026-07-29T17:12:08","modified_gmt":"2026-07-29T09:12:08","slug":"pneumatic-butterfly-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/ar\/product\/pneumatic-butterfly-valve\/","title":{"rendered":"\u0635\u0645\u0627\u0645 \u0641\u0631\u0627\u0634\u0629 \u0647\u0648\u0627\u0626\u064a"},"content":{"rendered":"<div class=\"rv-product-content rvp-content\">\n<section id=\"overview\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Engineering scope<\/div>\n<h2>Define the application boundary for Pneumatic Butterfly Valve<\/h2>\n<p class=\"rvp-lead\">A Pneumatic Butterfly Valve is evaluated for compact quarter-turn isolation or regulation. A disc rotates within the body and piping bore. Offset geometry, seat construction, shaft support, flange interface and actuator torque determine sealing, wear and controllability.<\/p>\n<p>Use the name as a starting point. Technical approval still depends on air-operated actuator sizing, fail action, supply pressure and accessory package, the complete service envelope, installed interfaces and measurable acceptance.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Pneumatic<\/h3>\n<p>Air-operated actuator sizing, fail action, supply pressure and accessory package. State minimum\/normal air pressure, fail state, stroke time, duty, solenoid, positioner, switches and tubing requirements.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Application envelope<\/h3>\n<p>Confirm every pressure, temperature, differential-pressure and cycling case for this Pneumatic Butterfly Valve.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Installed interface<\/h3>\n<p>Verify ends, bore, flow direction, orientation, operator envelope, loads and maintenance access.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Order-specific boundary<\/h3>\n<p>Website content is not tag-level certification. Suitability and supplied scope are established only by the accepted quotation, datasheet and drawing.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"specifications\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Specification workflow<\/div>\n<h2>Build the technical requirement before approving the model<\/h2>\n<p class=\"rvp-lead\">Record the question, accepted answer and proof so the Pneumatic Butterfly Valve proposal can be audited across disciplines.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Review area<\/th>\n<th>Engineering question<\/th>\n<th>Required record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Disc and seat geometry<\/td>\n<td>Concentric, double-offset or triple-offset construction must match shutoff and temperature duty.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<tr>\n<td>Piping interface<\/td>\n<td>Wafer, lug, flanged or welded bodies require compatible flange dimensions, gaskets and disc clearance.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<tr>\n<td>Torque basis<\/td>\n<td>Seating, bearing, packing and hydrodynamic torque must be checked at every operating case.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<tr>\n<td>Flow duty<\/td>\n<td>On-off, throttling, minimum opening and velocity limits should be stated.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<tr>\n<td>Pneumatic<\/td>\n<td>State minimum\/normal air pressure, fail state, stroke time, duty, solenoid, positioner, switches and tubing requirements.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\">A standard title alone is not acceptance. Map its scope, edition and required evidence to the valve tag.<\/p>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"rvp-section rvp-dark\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Application boundaries<\/div>\n<h2>Where this configuration may fit\u2014and what can make it fail<\/h2>\n<p>Check disc clearance, installation orientation and transient loads; a nominal flange fit does not prove that the disc can open safely. Also review orientation, transients, cycling, contamination, access and consequences of internal or external leakage.<\/p>\n<div class=\"rvp-checks\">\n<div class=\"rvp-check\">Fluid composition plus minimum, normal, maximum, startup and upset cases for the Pneumatic Butterfly Valve<\/div>\n<div class=\"rvp-check\">Isolation\/control\/non-return function, frequency, directionality and measurable shutoff acceptance<\/div>\n<div class=\"rvp-check\">Nominal interface plus the flange\/weld details, flow direction, face-to-face and operator envelope<\/div>\n<div class=\"rvp-check\">Corrosion and wear basis with exact body, trim, sealing, bolting, overlay, lining or coating materials<\/div>\n<div class=\"rvp-check\">Worst-case torque\/thrust, cycle duty, travel time, fail behavior, minimum utility and control accessories<\/div>\n<div class=\"rvp-check\">Exact standards and editions, ITP points, material\/NDE\/pressure\/leakage tests and turnover index<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Evidence and quality<\/div>\n<h2>Define the manufacturing and test proof before release<\/h2>\n<p class=\"rvp-lead\">Generic examples may explain capability but cannot close an order requirement unless they apply to the delivered valve. Use the <a href=\"\/valve-standards\/\">valve standards guide<\/a> to separate product, rating, dimensional, end-connection and test scope.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Design basis<\/h3>\n<p>Approved datasheet, drawing, bill of materials, rating basis and documented deviations.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Material identity<\/h3>\n<p>Component certificates, heat or lot traceability, heat treatment, hardness and required PMI or NDE.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Inspection and tests<\/h3>\n<p>Hold\/witness records, material\/NDE\/pressure\/leakage\/functional results and nonconformance closure.<\/p>\n<\/div>\n<\/div>\n<p>Size at minimum available supply pressure and maximum valve load.<\/p>\n<p>Qualification, testing and material suitability are conditional on the approved scope and supplied records for the actual configuration.<\/p>\n<\/div>\n<\/section>\n<section id=\"rfq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">RFQ checklist<\/div>\n<h2>Data to send for a technically complete quotation<\/h2>\n<p>Provide a controlled valve list or datasheet covering every operating case, interface, material, operation, standard, inspection, test and document requirement.<\/p>\n<p>For a Pneumatic Butterfly Valve, also highlight air-operated actuator sizing, fail action, supply pressure and accessory package. Identify missing inputs and provisional selections so they can be closed before purchase order release.<\/p>\n<div class=\"rvp-cta\">\n<div>\n<h2>Turn the datasheet into a clarified quotation basis<\/h2>\n<p>Provide the actual application; the response will separate confirmed requirements from assumptions and identify the checks still required.<\/p>\n<\/div>\n<div class=\"rvp-actions\"><a class=\"rvp-btn rvp-btn-primary\" href=\"\/contact\/\">Submit Your Datasheet<\/a><a class=\"rvp-btn rvp-btn-ghost\" href=\"\/butterfly-valves\/\">Compare Butterfly Valve Options<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Related engineering route<\/div>\n<h2>Use the related pages to close remaining decisions<\/h2>\n<div class=\"rvp-grid\"><a class=\"rvp-card\" href=\"\/butterfly-valves\/\"><\/p>\n<h3>Product family<\/h3>\n<p>Compare the main constructions and selection boundaries in this valve family.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-solutions\/\"><\/p>\n<h3>Project Valve Review<\/h3>\n<p>Resolve interacting pressure, temperature, corrosion, wear or project risks.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-pressure-testing\/\"><\/p>\n<h3>Testing and inspection<\/h3>\n<p>Define pressure-test scope, acceptance, instruments, witness points and records.<\/p>\n<p><\/a><\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-CSS-START --><\/p>\n<style id=\"rvq-quality-css\">.rvq-section{padding:68px 0;font-family:Arial,Helvetica,sans-serif;color:#17233a;line-height:1.7}.rvq-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rvq-intent{background:#f4f7fb}.rvq-trust{background:#fff}.rvq-kicker{color:#07549a;font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rvq-section h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:#0b1731}.rvq-lead{max-width:900px;color:#5c6779;font-size:17px}.rvq-tablewrap{overflow-x:auto;margin-top:28px;border:1px solid #dfe5ee;border-radius:12px;background:#fff}.rvq-table{width:100%;border-collapse:collapse;min-width:760px}.rvq-table th{background:#07549a;color:#fff;text-align:left;padding:15px}.rvq-table td{padding:15px;border-bottom:1px solid #dfe5ee;vertical-align:top}.rvq-table tr:last-child td{border-bottom:0}.rvq-source,.rvq-boundary{margin-top:22px;padding:20px;border-left:5px solid #f3cc18;background:#fff8d8;border-radius:8px}.rvq-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin:25px 0}.rvq-grid>div{border:1px solid #dfe5ee;border-radius:10px;padding:18px;background:#f8fafc}.rvq-grid b,.rvq-grid span{display:block}.rvq-grid b{color:#07549a;margin-bottom:5px}.rvq-grid span{font-size:14px;color:#5c6779}@media(max-width:800px){.rvq-grid{grid-template-columns:1fr 1fr}}@media(max-width:520px){.rvq-wrap{width:min(100% - 28px,1160px)}.rvq-section{padding:50px 0}.rvq-grid{grid-template-columns:1fr}}<\/style>\n<p><!-- RVQ-CSS-END --><!-- RVQ-INTENT-START --><\/p>\n<section class=\"rvq-section rvq-intent\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Task-specific answer<\/div>\n<h2>Convert Pneumatic Butterfly Valve from a broad request into an auditable engineering decision<\/h2>\n<p class=\"rvq-lead\">This section addresses the decision a visitor is likely trying to complete\u2014not merely the meaning of the page title. Use it to identify required inputs, compare the proposal and specify the record that will prove acceptance.<\/p>\n<div class=\"rvq-tablewrap\">\n<table class=\"rvq-table\">\n<thead>\n<tr>\n<th>Decision<\/th>\n<th>What to do<\/th>\n<th>Evidence to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Problem statement<\/b><\/td>\n<td>For Pneumatic Butterfly Valve, define the required system outcome, failure consequence and measurable acceptance before choosing hardware.<\/td>\n<td>Functional requirement<\/td>\n<\/tr>\n<tr>\n<td><b>Feasible routes<\/b><\/td>\n<td>Compare at least the practical construction, material, sealing and actuation alternatives, including reasons for rejection.<\/td>\n<td>Option and trade-off matrix<\/td>\n<\/tr>\n<tr>\n<td><b>Boundary conditions<\/b><\/td>\n<td>Check every normal, transient, startup, shutdown, maintenance and utility-loss case that can change the solution.<\/td>\n<td>Approved application data<\/td>\n<\/tr>\n<tr>\n<td><b>Validation<\/b><\/td>\n<td>Connect each claimed benefit to a calculation, drawing, qualification, inspection or package-level test that applies to the order.<\/td>\n<td>Verification and evidence plan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rvq-boundary\"><b>Decision boundary:<\/b> This guidance supports screening and RFQ preparation. Final suitability, compliance and supplied scope require the actual application data, governing jurisdiction, contract documents, approved supplier submittals and tag-linked records.<\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-INTENT-END --><!-- RVQ-TRUST-START --><\/p>\n<section class=\"rvq-section rvq-trust\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Content responsibility &amp; evidence<\/div>\n<h2>How this Pneumatic Butterfly Valve guide should be used<\/h2>\n<div class=\"rvq-grid\">\n<div><b>Publisher<\/b><span>Raymon Valve technical content team<\/span><\/div>\n<div><b>Purpose<\/b><span>Engineering screening, specification and RFQ preparation<\/span><\/div>\n<div><b>Content update<\/b><span>29 July 2026<\/span><\/div>\n<div><b>Verification level<\/b><span>Topic scope, search intent and evidence boundaries checked<\/span><\/div>\n<\/div>\n<p>This page does not claim that a named person, certificate, qualification, installed project or performance result applies to a future order. Product compliance is confirmed only when the accepted quotation, approved drawing, procedures and final manufacturing\/test records identify the supplied configuration.<\/p>\n<p>Technical requirements and standards can change. Verify the official source, contract edition, project precedence and purchaser options. See our <a href=\"\/technical-content-review-policy\/\">technical content review and evidence policy<\/a>, <a href=\"\/about-us\/\">company information<\/a>, <a href=\"\/valve-inspection\/\">inspection approach<\/a> or <a href=\"\/contact\/\">submit a correction or application question<\/a>.<\/p>\n<\/div>\n<\/section>\n<p><!-- RVQ-TRUST-END --><!-- RVQ-SCHEMA-START --><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"WebPage\",\"name\":\"Pneumatic Butterfly Valve\",\"url\":\"https:\/\/raymonvalve.com\/product\/pneumatic-butterfly-valve\/\",\"dateModified\":\"2026-07-29\",\"description\":\"Product selection guide for Pneumatic Butterfly Valve, with application boundaries, decision inputs and order-specific evidence requirements.\",\"publisher\":{\"@type\":\"Organization\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"isPartOf\":{\"@type\":\"WebSite\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"about\":{\"@type\":\"Thing\",\"name\":\"Pneumatic Butterfly Valve\"}}<\/script><!-- RVQ-SCHEMA-END --><\/p>\n<section id=\"faq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">FAQ<\/div>\n<h2>Pneumatic Butterfly Valve questions<\/h2>\n<div class=\"rvp-faq\">\n<details>\n<summary>What information is required to select a Pneumatic Butterfly Valve?<\/summary>\n<p>Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address air-operated actuator sizing, fail action, supply pressure and accessory package.<\/p>\n<\/details>\n<details>\n<summary>Which standards apply to a Pneumatic Butterfly Valve?<\/summary>\n<p>The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Size at minimum available supply pressure and maximum valve load.<\/p>\n<\/details>\n<details>\n<summary>How should Pneumatic Butterfly Valve pressure and leakage testing be specified?<\/summary>\n<p>State the governing standard and approved edition, shell and closure basis, medium, pressure, duration, leakage acceptance, directionality, instruments, witness points and report format.<\/p>\n<\/details>\n<details>\n<summary>Can a Pneumatic Butterfly Valve be supplied with an actuator?<\/summary>\n<p>Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.<\/p>\n<\/details>\n<details>\n<summary>When should a Pneumatic Butterfly Valve not be selected?<\/summary>\n<p>Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Check disc clearance, installation orientation and transient loads; a nominal flange fit does not prove that the disc can open safely. The alternative should be chosen only after comparing the complete service duty.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What information is required to select a Pneumatic Butterfly Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address air-operated actuator sizing, fail action, supply pressure and accessory package.\"}}, {\"@type\": \"Question\", \"name\": \"Which standards apply to a Pneumatic Butterfly Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Size at minimum available supply pressure and maximum valve load.\"}}, {\"@type\": \"Question\", \"name\": \"How should Pneumatic Butterfly Valve pressure and leakage testing be specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"State the governing standard and approved edition, shell and closure basis, medium, pressure, duration, leakage acceptance, directionality, instruments, witness points and report format.\"}}, {\"@type\": \"Question\", \"name\": \"Can a Pneumatic Butterfly Valve be supplied with an actuator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.\"}}, {\"@type\": \"Question\", \"name\": \"When should a Pneumatic Butterfly Valve not be selected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Check disc clearance, installation orientation and transient loads; a nominal flange fit does not prove that the disc can open safely. The alternative should be chosen only after comparing the complete service duty.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0635\u0645\u0627\u0645 \u0641\u0631\u0627\u0634\u0629 \u0647\u0648\u0627\u0626\u064a \u0644\u0644\u0639\u0632\u0644 \u0623\u0648 \u0627\u0644\u062a\u0646\u0638\u064a\u0645 \u0628\u0631\u0628\u0639 \u062f\u0648\u0631\u0629 \u0645\u062f\u0645\u062c \u0645\u062d\u062f\u062f \u0644\u0644\u0645\u0634\u0631\u0648\u0639. \u062a\u0639\u0627\u0644\u062c \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u062a\u062d\u062f\u064a\u062f \u062d\u062c\u0645 \u0627\u0644\u0645\u0634\u063a\u0644 \u0627\u0644\u0630\u064a \u064a\u0639\u0645\u0644 \u0628\u0627\u0644\u0647\u0648\u0627\u0621\u060c \u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0641\u0634\u0644\u060c \u0636\u063a\u0637 \u0627\u0644\u0625\u0645\u062f\u0627\u062f \u0648\u062d\u0632\u0645\u0629 \u0627\u0644\u0645\u0644\u062d\u0642\u0627\u062a\u060c \u0627\u0644\u0645\u0648\u0627\u062f\u060c \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0648\u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u0648\u062b\u0642 \u0642\u0628\u0644 \u0625\u0635\u062f\u0627\u0631 \u0639\u0631\u0636 \u0627\u0644\u0633\u0639\u0631.<\/p>","protected":false},"featured_media":12410,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-10857","product","type-product","status-publish","has-post-thumbnail","product_cat-butterfly-valves","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-gallery-with-no-image","ast-product-tabs-layout-horizontal","ast-qv-on-image","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/product\/10857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/comments?post=10857"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media\/12410"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/media?parent=10857"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/product_brand?post=10857"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/product_cat?post=10857"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/ar\/wp-json\/wp\/v2\/product_tag?post=10857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}