{"id":3705,"date":"2022-08-24T09:17:02","date_gmt":"2022-08-24T01:17:02","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?post_type=product&#038;p=3705"},"modified":"2026-07-29T19:24:21","modified_gmt":"2026-07-29T11:24:21","slug":"general-angle-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/de\/product\/general-angle-valve\/","title":{"rendered":"Schr\u00e4gsitz-Regelventil f\u00fcr allgemeine Anwendungen"},"content":{"rendered":"<div class=\"rv-product-content rvp-content\">\n<section id=\"overview\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Engineering scope<\/div>\n<h2>What controls a responsible General-Service Angle Control Valve selection<\/h2>\n<p class=\"rvp-lead\">A General-Service Angle Control Valve is evaluated for modulating process control. A throttling element changes effective flow area in response to a control signal. Installed characteristic, Cv, pressure recovery, trim velocity and actuator resolution determine control quality.<\/p>\n<p>The product name narrows the route but does not complete the specification. Resolve 90-degree body flow path, piping loads and erosion or flashing exposure together with the medium, operating cases, piping interface, maintenance and evidence.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Angle<\/h3>\n<p>90-degree body flow path, piping loads and erosion or flashing exposure. Define flow direction, pressure drop, phase, velocity, piping loads, drainage and maintenance access.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Application envelope<\/h3>\n<p>Confirm every pressure, temperature, differential-pressure and cycling case for this General-Service Angle Control Valve.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Installed interface<\/h3>\n<p>Verify ends, bore, flow direction, orientation, operator envelope, loads and maintenance access.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Order-specific boundary<\/h3>\n<p>Website content is not tag-level certification. Suitability and supplied scope are established only by the accepted quotation, datasheet and drawing.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"published-data\" class=\"rvp-section rvp-legacy-data\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Existing listing data<\/div>\n<h2>Published configuration data for General-Service Angle Control Valve\u2014confirmation required<\/h2>\n<p class=\"rvp-lead\">The values below are transcribed from the previous public product listing so useful model information is not lost during the quality rebuild. They are not a universal available range, certificate or order commitment. Confirm every value in the accepted quotation, tag datasheet and approved drawing.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Previous listing<\/th>\n<th>Required order check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Product type<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm the exact model, construction and supplied configuration.<\/td>\n<\/tr>\n<tr>\n<td><b>Nominal size \/ DN<\/b><\/td>\n<td>40-300<\/td>\n<td>Confirm each ordered tag and available trim or bore combination.<\/td>\n<\/tr>\n<tr>\n<td><b>Pressure rating<\/b><\/td>\n<td>PN16-110 ANSI Class 150-600<\/td>\n<td>Confirm governing rating standard, class and temperature basis.<\/td>\n<\/tr>\n<tr>\n<td><b>Temperature<\/b><\/td>\n<td>196~+566\u2103<\/td>\n<td>Confirm design, operating, startup and upset metal temperatures.<\/td>\n<\/tr>\n<tr>\n<td><b>End connection<\/b><\/td>\n<td>GBDIN, ANSI JIS, etc.<\/td>\n<td>Confirm standard, facing, schedule, bore and mating interface.<\/td>\n<\/tr>\n<tr>\n<td><b>Flow coefficient \/ characteristic<\/b><\/td>\n<td>10-1400<\/td>\n<td>Confirm calculated cases, trim, travel and installed behavior.<\/td>\n<\/tr>\n<tr>\n<td><b>Body \/ bonnet material<\/b><\/td>\n<td>carbon steel, stainless steel, special alloy steel<\/td>\n<td>Confirm component grade, product form, heat treatment and records.<\/td>\n<\/tr>\n<tr>\n<td><b>Trim \/ closure material<\/b><\/td>\n<td>stainless steel. Stainless steel + hardened. Stainless steel + cemented carbide, special alloy steel stainless steel + PTFE Optional: &#8211; Bellows seal &#8211; Insulation jacket -Luft low leakage packing Features: -Optimized actuator for various air supply conditions &#8211;<\/td>\n<td>Confirm every wetted component, hardness, coating and pairing.<\/td>\n<\/tr>\n<tr>\n<td><b>Seat \/ seal material<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm compatibility, leakage criterion and pressure-temperature limit.<\/td>\n<\/tr>\n<tr>\n<td><b>Operation \/ actuator<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm worst-case load, fail state, utilities, speed and accessories.<\/td>\n<\/tr>\n<tr>\n<td><b>Leakage basis<\/b><\/td>\n<td>V V and V class Material:<\/td>\n<td>Confirm standard, edition, test direction, medium and measurable acceptance.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\"><b>Evidence boundary:<\/b> where the previous listing was incomplete or awkwardly translated, this page does not guess a value. Raymon Valve should replace provisional web data with the controlled product datasheet when it is available.<\/p>\n<\/div>\n<\/section>\n<section id=\"specifications\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Specification workflow<\/div>\n<h2>Build the technical requirement before approving the model<\/h2>\n<p class=\"rvp-lead\">The table turns application inputs for General-Service Angle Control Valve into review points and tag-linked evidence.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Review area<\/th>\n<th>Engineering question<\/th>\n<th>Required record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Sizing cases<\/td>\n<td>Minimum, normal, maximum, startup and upset cases require verified fluid properties and pressures.<\/td>\n<td>Name the controlling document, responsible reviewer and inspection or calculation record.<\/td>\n<\/tr>\n<tr>\n<td>Trim duty<\/td>\n<td>Cavitation, flashing, choked gas flow, noise, erosion and rangeability must be evaluated.<\/td>\n<td>State the measurable requirement and connect it to a drawing, procedure or test result.<\/td>\n<\/tr>\n<tr>\n<td>Actuator<\/td>\n<td>Required thrust or torque, fail action, stroking speed and utility supply must be coordinated.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<tr>\n<td>Accessories<\/td>\n<td>Positioner, solenoids, limit switches, air set and hazardous-area requirements form one package.<\/td>\n<td>State the measurable requirement and connect it to a drawing, procedure or test result.<\/td>\n<\/tr>\n<tr>\n<td>Angle<\/td>\n<td>Define flow direction, pressure drop, phase, velocity, piping loads, drainage and maintenance access.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\">Record exact standard designations and contract editions; resolve scope gaps and purchaser options before manufacture.<\/p>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"rvp-section rvp-dark\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Application boundaries<\/div>\n<h2>Service conditions that can change or reject the selection<\/h2>\n<p>Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The final decision must cover system interactions, end-of-life loads, degradation and how failure will be detected or contained.<\/p>\n<div class=\"rvp-checks\">\n<div class=\"rvp-check\">Complete medium composition, pressure, temperature and flow cases for the General-Service Angle Control Valve<\/div>\n<div class=\"rvp-check\">Isolation\/control\/non-return function, frequency, directionality and measurable shutoff acceptance<\/div>\n<div class=\"rvp-check\">Nominal interface plus the flange\/weld details, flow direction, face-to-face and operator envelope<\/div>\n<div class=\"rvp-check\">Component-level materials for pressure parts, wetted trim, seats, stem\/shaft, packing, gaskets and fasteners<\/div>\n<div class=\"rvp-check\">Manual or actuated operation, maximum load, fail action, speed, utilities and accessories<\/div>\n<div class=\"rvp-check\">Product, rating, dimensions, ends and test requirements plus special qualification and tag-linked evidence<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Evidence and quality<\/div>\n<h2>Define the manufacturing and test proof before release<\/h2>\n<p class=\"rvp-lead\">A certificate or report is useful only when its scope traces to the actual tag, materials and configuration. Use the <a href=\"\/valve-standards\/\">valve standards guide<\/a> to separate product, rating, dimensional, end-connection and test scope.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Design basis<\/h3>\n<p>Tag requirements, design review, materials list and approved exception register.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Material identity<\/h3>\n<p>Pressure and wetted-part traceability plus welding, heat treatment, hardness and inspection evidence.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Inspection and tests<\/h3>\n<p>Hold\/witness records, material\/NDE\/pressure\/leakage\/functional results and nonconformance closure.<\/p>\n<\/div>\n<\/div>\n<p>The body turn can concentrate velocity and erosion; geometry must suit the process case.<\/p>\n<p>No statement here is an unqualified certification claim; standards, editions and evidence remain subject to project review.<\/p>\n<\/div>\n<\/section>\n<section id=\"rfq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">RFQ checklist<\/div>\n<h2>Information needed for a tag-level technical offer<\/h2>\n<p>A useful RFQ combines process data, piping class, construction and materials, operator\/actuator requirements, acceptance criteria and delivery documents.<\/p>\n<p>For a General-Service Angle Control Valve, also highlight 90-degree body flow path, piping loads and erosion or flashing exposure. Identify missing inputs and provisional selections so they can be closed before purchase order release.<\/p>\n<div class=\"rvp-cta\">\n<div>\n<h2>Request a tag-level technical review<\/h2>\n<p>Share the datasheet, line class and evidence scope so open points and deviations can be resolved before order release.<\/p>\n<\/div>\n<div class=\"rvp-actions\"><a class=\"rvp-btn rvp-btn-primary\" href=\"\/contact\/\">Submit Your Datasheet<\/a><a class=\"rvp-btn rvp-btn-ghost\" href=\"\/control-valves\/\">Compare Control Valve Options<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Related engineering route<\/div>\n<h2>Use the related pages to close remaining decisions<\/h2>\n<div class=\"rvp-grid\"><a class=\"rvp-card\" href=\"\/control-valves\/\"><\/p>\n<h3>Product family<\/h3>\n<p>Compare the main constructions and selection boundaries in this valve family.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-solutions\/\"><\/p>\n<h3>Project Valve Review<\/h3>\n<p>Resolve interacting pressure, temperature, corrosion, wear or project risks.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-pressure-testing\/\"><\/p>\n<h3>Testing and inspection<\/h3>\n<p>Define pressure-test scope, acceptance, instruments, witness points and records.<\/p>\n<p><\/a><\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-CSS-START --><\/p>\n<style id=\"rvq-quality-css\">.rvq-section{padding:68px 0;font-family:Arial,Helvetica,sans-serif;color:#17233a;line-height:1.7}.rvq-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rvq-intent{background:#f4f7fb}.rvq-trust{background:#fff}.rvq-kicker{color:#07549a;font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rvq-section h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:#0b1731}.rvq-lead{max-width:900px;color:#5c6779;font-size:17px}.rvq-tablewrap{overflow-x:auto;margin-top:28px;border:1px solid #dfe5ee;border-radius:12px;background:#fff}.rvq-table{width:100%;border-collapse:collapse;min-width:760px}.rvq-table th{background:#07549a;color:#fff;text-align:left;padding:15px}.rvq-table td{padding:15px;border-bottom:1px solid #dfe5ee;vertical-align:top}.rvq-table tr:last-child td{border-bottom:0}.rvq-source,.rvq-boundary{margin-top:22px;padding:20px;border-left:5px solid #f3cc18;background:#fff8d8;border-radius:8px}.rvq-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin:25px 0}.rvq-grid>div{border:1px solid #dfe5ee;border-radius:10px;padding:18px;background:#f8fafc}.rvq-grid b,.rvq-grid span{display:block}.rvq-grid b{color:#07549a;margin-bottom:5px}.rvq-grid span{font-size:14px;color:#5c6779}@media(max-width:800px){.rvq-grid{grid-template-columns:1fr 1fr}}@media(max-width:520px){.rvq-wrap{width:min(100% - 28px,1160px)}.rvq-section{padding:50px 0}.rvq-grid{grid-template-columns:1fr}}<\/style>\n<p><!-- RVQ-CSS-END --><!-- RVQ-INTENT-START --><\/p>\n<section class=\"rvq-section rvq-intent\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Task-specific answer<\/div>\n<h2>Convert General-Service Angle Control Valve from a broad request into an auditable engineering decision<\/h2>\n<p class=\"rvq-lead\">This section addresses the decision a visitor is likely trying to complete\u2014not merely the meaning of the page title. Use it to identify required inputs, compare the proposal and specify the record that will prove acceptance.<\/p>\n<div class=\"rvq-tablewrap\">\n<table class=\"rvq-table\">\n<thead>\n<tr>\n<th>Decision<\/th>\n<th>What to do<\/th>\n<th>Evidence to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Problem statement<\/b><\/td>\n<td>For General-Service Angle Control Valve, define the required system outcome, failure consequence and measurable acceptance before choosing hardware.<\/td>\n<td>Functional requirement<\/td>\n<\/tr>\n<tr>\n<td><b>Feasible routes<\/b><\/td>\n<td>Compare at least the practical construction, material, sealing and actuation alternatives, including reasons for rejection.<\/td>\n<td>Option and trade-off matrix<\/td>\n<\/tr>\n<tr>\n<td><b>Boundary conditions<\/b><\/td>\n<td>Check every normal, transient, startup, shutdown, maintenance and utility-loss case that can change the solution.<\/td>\n<td>Approved application data<\/td>\n<\/tr>\n<tr>\n<td><b>Validation<\/b><\/td>\n<td>Connect each claimed benefit to a calculation, drawing, qualification, inspection or package-level test that applies to the order.<\/td>\n<td>Verification and evidence plan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rvq-boundary\"><b>Decision boundary:<\/b> This guidance supports screening and RFQ preparation. Final suitability, compliance and supplied scope require the actual application data, governing jurisdiction, contract documents, approved supplier submittals and tag-linked records.<\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-INTENT-END --><!-- RVQ-TRUST-START --><\/p>\n<section class=\"rvq-section rvq-trust\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Content responsibility &amp; evidence<\/div>\n<h2>How this General-Service Angle Control Valve guide should be used<\/h2>\n<div class=\"rvq-grid\">\n<div><b>Publisher<\/b><span>Raymon Valve technical content team<\/span><\/div>\n<div><b>Purpose<\/b><span>Engineering screening, specification and RFQ preparation<\/span><\/div>\n<div><b>Content update<\/b><span>29 July 2026<\/span><\/div>\n<div><b>Verification level<\/b><span>Topic scope, search intent and evidence boundaries checked<\/span><\/div>\n<\/div>\n<p>This page does not claim that a named person, certificate, qualification, installed project or performance result applies to a future order. Product compliance is confirmed only when the accepted quotation, approved drawing, procedures and final manufacturing\/test records identify the supplied configuration.<\/p>\n<p>Technical requirements and standards can change. Verify the official source, contract edition, project precedence and purchaser options. See our <a href=\"\/technical-content-review-policy\/\">technical content review and evidence policy<\/a>, <a href=\"\/about-us\/\">company information<\/a>, <a href=\"\/valve-inspection\/\">inspection approach<\/a> or <a href=\"\/contact\/\">submit a correction or application question<\/a>.<\/p>\n<\/div>\n<\/section>\n<p><!-- RVQ-TRUST-END --><!-- RVQ-SCHEMA-START --><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"WebPage\",\"name\":\"General-Service Angle Control Valve\",\"url\":\"https:\/\/raymonvalve.com\/product\/general-angle-valve\/\",\"dateModified\":\"2026-07-29\",\"description\":\"Product selection guide for General-Service Angle Control Valve, with application boundaries, decision inputs and order-specific evidence requirements.\",\"publisher\":{\"@type\":\"Organization\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"isPartOf\":{\"@type\":\"WebSite\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"about\":{\"@type\":\"Thing\",\"name\":\"General-Service Angle Control Valve\"}}<\/script><!-- RVQ-SCHEMA-END --><\/p>\n<section id=\"faq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">FAQ<\/div>\n<h2>General-Service Angle Control Valve questions<\/h2>\n<div class=\"rvp-faq\">\n<details>\n<summary>What information is required to select a General-Service Angle Control Valve?<\/summary>\n<p>Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address 90-degree body flow path, piping loads and erosion or flashing exposure.<\/p>\n<\/details>\n<details>\n<summary>Which standards apply to a General-Service Angle Control Valve?<\/summary>\n<p>The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. The body turn can concentrate velocity and erosion; geometry must suit the process case.<\/p>\n<\/details>\n<details>\n<summary>How should General-Service Angle Control Valve pressure and leakage testing be specified?<\/summary>\n<p>Separate pressure-boundary, closure, functional and any special testing. Record the procedure, edition, duration, allowable leakage, intervention point and final evidence.<\/p>\n<\/details>\n<details>\n<summary>Can a General-Service Angle Control Valve be supplied with an actuator?<\/summary>\n<p>Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.<\/p>\n<\/details>\n<details>\n<summary>When should a General-Service Angle Control Valve not be selected?<\/summary>\n<p>Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The alternative should be chosen only after comparing the complete service duty.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What information is required to select a General-Service Angle Control Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address 90-degree body flow path, piping loads and erosion or flashing exposure.\"}}, {\"@type\": \"Question\", \"name\": \"Which standards apply to a General-Service Angle Control Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. The body turn can concentrate velocity and erosion; geometry must suit the process case.\"}}, {\"@type\": \"Question\", \"name\": \"How should General-Service Angle Control Valve pressure and leakage testing be specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Separate pressure-boundary, closure, functional and any special testing. Record the procedure, edition, duration, allowable leakage, intervention point and final evidence.\"}}, {\"@type\": \"Question\", \"name\": \"Can a General-Service Angle Control Valve be supplied with an actuator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.\"}}, {\"@type\": \"Question\", \"name\": \"When should a General-Service Angle Control Valve not be selected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The alternative should be chosen only after comparing the complete service duty.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Winkelregelventil f\u00fcr allgemeine Anwendungen f\u00fcr projektdefinierte, modulierende Prozessregelung. Die Auswahl ber\u00fccksichtigt den 90-Grad-Str\u00f6mungsweg des Geh\u00e4uses, Rohrleitungsbelastungen und Erosions- oder Kavitationsbelastung, Werkstoffe, Betrieb, Pr\u00fcfung und dokumentierte Abnahme vor der Angebotserstellung.<\/p>","protected":false},"featured_media":3706,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[178,316,295],"product_tag":[],"class_list":["post-3705","product","type-product","status-publish","has-post-thumbnail","product_cat-control-valves","product_cat-angle-valve","product_cat-globe-pneumatic-control-valve","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-gallery-with-no-image","ast-product-tabs-layout-horizontal","ast-qv-on-image","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/product\/3705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/comments?post=3705"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/media\/3706"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/media?parent=3705"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/product_brand?post=3705"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/product_cat?post=3705"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/de\/wp-json\/wp\/v2\/product_tag?post=3705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}