{"id":14716,"date":"2026-09-20T11:17:12","date_gmt":"2026-09-20T03:17:12","guid":{"rendered":"https:\/\/raymonvalve.com\/?p=14716"},"modified":"2026-09-20T11:17:51","modified_gmt":"2026-09-20T03:17:51","slug":"api-6d-vs-api-608-ball-valve","status":"publish","type":"post","link":"https:\/\/raymonvalve.com\/es\/blog\/api-6d-vs-api-608-ball-valve\/","title":{"rendered":"API 6D vs API 608 Ball Valve: Pipeline Service, Design Scope, Testing and Selection"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"14716\" class=\"elementor elementor-14716\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c86f78a e-flex e-con-boxed e-con e-parent\" data-id=\"5c86f78a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-319c5f60 elementor-widget elementor-widget-text-editor\" data-id=\"319c5f60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"text-align: left;\"><style>\n.raymonvalve-blog-page{\n  --rv-primary:#123f67;\n  --rv-secondary:#17679a;\n  --rv-accent:#e8f3fa;\n  --rv-soft:#f6f8fa;\n  --rv-border:#dbe4eb;\n  --rv-text:#263746;\n  --rv-muted:#617383;\n  --rv-warning-bg:#fff8e8;\n  --rv-warning-border:#cc8c16;\n  --rv-experience-bg:#f8fafc;\n  --rv-experience-border:#91a8b8;\n  max-width:1160px;\n  margin:0 auto;\n  padding:24px 20px 60px;\n  color:var(--rv-text);\n  font-family:Arial,Helvetica,sans-serif;\n  line-height:1.72;\n  overflow-wrap:anywhere;\n}\n\n.raymonvalve-blog-page .rv-content{\n  max-width:820px;\n  margin:0 auto;\n}\n\n.raymonvalve-blog-page p{\n  margin:0 0 18px;\n}\n\n.raymonvalve-blog-page h2{\n  margin:48px 0 18px;\n  color:#153b5c;\n  font-size:30px;\n  line-height:1.25;\n}\n\n.raymonvalve-blog-page h3{\n  margin:30px 0 12px;\n  color:#1f5278;\n  font-size:22px;\n  line-height:1.35;\n}\n\n.raymonvalve-blog-page ul,\n.raymonvalve-blog-page ol{\n  margin:0 0 22px;\n  padding-left:24px;\n}\n\n.raymonvalve-blog-page li{\n  margin-bottom:8px;\n}\n\n.raymonvalve-blog-page a{\n  color:#0b68a0;\n  text-decoration:underline;\n  text-underline-offset:2px;\n}\n\n.raymonvalve-blog-page a:focus-visible,\n.raymonvalve-blog-page summary:focus-visible{\n  outline:3px solid #1b78af;\n  outline-offset:3px;\n}\n\n.raymonvalve-blog-page .rv-lead{\n  font-size:18px;\n  line-height:1.72;\n  color:#314656;\n}\n\n.raymonvalve-blog-page .rv-answer{\n  margin:24px 0 30px;\n  padding:22px 24px;\n  border-left:4px solid var(--rv-secondary);\n  background:var(--rv-accent);\n  border-radius:6px;\n}\n\n.raymonvalve-blog-page .rv-note{\n  margin:26px 0;\n  padding:18px 20px;\n  background:#f7fafc;\n  border:1px solid var(--rv-border);\n  border-radius:8px;\n}\n\n.raymonvalve-blog-page .rv-warning{\n  margin:26px 0;\n  padding:18px 20px;\n  background:var(--rv-warning-bg);\n  border-left:4px solid var(--rv-warning-border);\n  border-radius:6px;\n}\n\n.raymonvalve-blog-page .rv-field-note{\n  margin:26px 0;\n  padding:18px 20px;\n  background:var(--rv-experience-bg);\n  border-left:4px solid var(--rv-experience-border);\n  border-radius:6px;\n}\n\n.raymonvalve-blog-page .rv-field-note strong{\n  color:#214d69;\n}\n\n.raymonvalve-blog-page .rv-image{\n  margin:30px auto 34px;\n}\n\n.raymonvalve-blog-page .rv-image img{\n  display:block;\n  width:100%;\n  height:auto;\n  border-radius:8px;\n}\n\n.raymonvalve-blog-page .rv-image figcaption{\n  margin-top:10px;\n  color:var(--rv-muted);\n  font-size:14px;\n  line-height:1.55;\n}\n\n.raymonvalve-blog-page .raymonvalve-table-wrap{\n  width:100%;\n  overflow-x:auto;\n  margin:24px 0 32px;\n  -webkit-overflow-scrolling:touch;\n}\n\n.raymonvalve-blog-page .rv-table{\n  width:100%;\n  min-width:720px;\n  border-collapse:collapse;\n  background:#fff;\n}\n\n.raymonvalve-blog-page .rv-table th,\n.raymonvalve-blog-page .rv-table td{\n  padding:13px 14px;\n  border:1px solid var(--rv-border);\n  text-align:left;\n  vertical-align:top;\n}\n\n.raymonvalve-blog-page .rv-table th{\n  background:#edf5fa;\n  color:#163e5d;\n  font-weight:700;\n}\n\n.raymonvalve-blog-page .rv-checklist{\n  margin:24px 0;\n  padding:22px 24px;\n  background:var(--rv-soft);\n  border-radius:8px;\n}\n\n.raymonvalve-blog-page .rv-checklist h3:first-child{\n  margin-top:0;\n}\n\n.raymonvalve-blog-page .rv-steps{\n  counter-reset:rvstep;\n  padding-left:0;\n  list-style:none;\n}\n\n.raymonvalve-blog-page .rv-steps li{\n  counter-increment:rvstep;\n  position:relative;\n  margin:0 0 20px;\n  padding:0 0 0 50px;\n}\n\n.raymonvalve-blog-page .rv-steps li::before{\n  content:counter(rvstep);\n  position:absolute;\n  top:0;\n  left:0;\n  width:34px;\n  height:34px;\n  display:flex;\n  align-items:center;\n  justify-content:center;\n  border-radius:50%;\n  background:var(--rv-primary);\n  color:#fff;\n  font-weight:700;\n}\n\n.raymonvalve-blog-page .rv-cta{\n  margin:42px 0;\n  padding:30px;\n  background:#123f67;\n  color:#fff;\n  border-radius:10px;\n}\n\n.raymonvalve-blog-page .rv-cta h2{\n  margin:0 0 14px;\n  color:#fff;\n}\n\n.raymonvalve-blog-page .rv-cta p{\n  color:#fff;\n}\n\n.raymonvalve-blog-page .rv-button{\n  display:inline-block;\n  margin-top:8px;\n  padding:13px 20px;\n  background:#fff;\n  color:#123f67;\n  border-radius:5px;\n  font-weight:700;\n  text-decoration:none;\n}\n\n.raymonvalve-blog-page .rv-button:hover,\n.raymonvalve-blog-page .rv-button:focus{\n  background:#edf5fa;\n}\n\n.raymonvalve-blog-page .rv-faq details{\n  margin-bottom:12px;\n  padding:16px 18px;\n  border:1px solid var(--rv-border);\n  border-radius:7px;\n  background:#fff;\n}\n\n.raymonvalve-blog-page .rv-faq summary{\n  cursor:pointer;\n  color:#183f5e;\n  font-weight:700;\n}\n\n.raymonvalve-blog-page .rv-faq details p{\n  margin:14px 0 2px;\n}\n\n.raymonvalve-blog-page .rv-related,\n.raymonvalve-blog-page .rv-references{\n  margin-top:34px;\n  padding:22px;\n  background:#f5f9fc;\n  border-radius:8px;\n}\n\n.raymonvalve-blog-page .rv-related h2,\n.raymonvalve-blog-page .rv-references h2{\n  margin-top:0;\n}\n\n.raymonvalve-blog-page .rv-engineering-note{\n  margin-top:42px;\n  padding:22px;\n  border-top:2px solid var(--rv-border);\n  background:#fafcfd;\n  font-size:15px;\n}\n\n@media (max-width:767px){\n  .raymonvalve-blog-page{\n    padding:18px 15px 45px;\n  }\n\n  .raymonvalve-blog-page h2{\n    margin-top:38px;\n    font-size:25px;\n  }\n\n  .raymonvalve-blog-page h3{\n    font-size:20px;\n  }\n\n  .raymonvalve-blog-page .rv-lead{\n    font-size:17px;\n  }\n\n  .raymonvalve-blog-page .rv-answer,\n  .raymonvalve-blog-page .rv-checklist,\n  .raymonvalve-blog-page .rv-cta,\n  .raymonvalve-blog-page .rv-note,\n  .raymonvalve-blog-page .rv-warning,\n  .raymonvalve-blog-page .rv-field-note,\n  .raymonvalve-blog-page .rv-related,\n  .raymonvalve-blog-page .rv-references{\n    padding:18px;\n  }\n\n  .raymonvalve-blog-page .rv-table{\n    min-width:680px;\n  }\n\n  .raymonvalve-blog-page .rv-button{\n    display:block;\n    width:100%;\n    box-sizing:border-box;\n    text-align:center;\n  }\n}\n<\/style><\/p>\n<article class=\"raymonvalve-blog-page\">\n<div class=\"rv-content\">\n<div class=\"rv-answer\">\n<p class=\"rv-lead\"><strong>API 6D and API 608 are both used to specify metal ball valves, but neither standard should be selected from installation location alone.<\/strong> API 6D covers a broader family of valves and project requirements, while API 608 focuses specifically on metal ball valves. For engineering and procurement, the practical decision depends on the governing project specification, valve construction, bore, pressure-temperature basis, testing, qualification requirements and supplier documentation.<\/p>\n<p>Neither designation alone proves that the offered valve is full bore, DBB\/DIB, fire-safe, fugitive-emission qualified, suitable for sour or hydrogen service, or acceptable for every project inspection requirement.<\/p>\n<\/div>\n<figure class=\"rv-image\"><img fetchpriority=\"high\" decoding=\"async\" title=\"API 6D vs API 608 Ball Valve Comparison\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-vs-api-608-ball-valve-comparison.webp\" alt=\"API 6D vs API 608 ball valve comparison showing pipeline and process piping specification context\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"engineering-schematic\" \/>\n<figcaption>Engineering comparison of API 6D and API 608 scope for ball valve specification. This is an explanatory engineering graphic, not certification evidence.<\/figcaption>\n<\/figure>\n<h2>API 6D vs API 608: What Is the Practical Difference?<\/h2>\n<p>The difference that matters most to a buyer is <strong>scope<\/strong>. API 6D addresses several valve types within a broader product and manufacturing framework, including ball valves. API 608 is specifically focused on metal ball valves.<\/p>\n<p>This does not make API 6D a universally higher-grade version of API 608. The correct standard is the one required by the governing owner, EPC or project documents and applicable to the proposed valve configuration and service.<\/p>\n<div class=\"raymonvalve-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"API 6D versus API 608 comparison table\">\n<table class=\"rv-table\">\n<thead>\n<tr>\n<th scope=\"col\">Decision Point<\/th>\n<th scope=\"col\">API 6D<\/th>\n<th scope=\"col\">API 608<\/th>\n<th scope=\"col\">Buyer Check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Primary scope<\/td>\n<td>Broader valve specification covering several valve types<\/td>\n<td>Metal ball valve product standard<\/td>\n<td>Which standard and edition does the project specification require?<\/td>\n<\/tr>\n<tr>\n<td>Valve type<\/td>\n<td>Includes ball valves and other covered valve types<\/td>\n<td>Ball valves<\/td>\n<td>Does the offered valve fall within the adopted standard scope?<\/td>\n<\/tr>\n<tr>\n<td>Typical project context<\/td>\n<td>Common in pipeline, transmission, terminal and related petroleum or natural-gas duties<\/td>\n<td>Common in refinery, petrochemical, process and general industrial ball-valve duties<\/td>\n<td>What piping, pipeline or owner specification governs the valve?<\/td>\n<\/tr>\n<tr>\n<td>Procurement review<\/td>\n<td>Design, manufacturing, testing, marking and documentation requirements must be read with purchaser requirements<\/td>\n<td>Ball-valve-specific requirements must still be combined with project testing and documentation<\/td>\n<td>What supplementary tests, qualification evidence and documents are required?<\/td>\n<\/tr>\n<tr>\n<td>Final suitability<\/td>\n<td>Project-specific<\/td>\n<td>Project-specific<\/td>\n<td>Review the complete datasheet and technical offer before approval.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rv-note\"><strong>Current-edition note:<\/strong> At the time of this review, API Specification 6D, <em>Specification for Valves<\/em>, is the 25th Edition with Addendum 3 issued March 5, 2025. API Standard 608, <em>Metal Ball Valves\u2014Flanged, Threaded and Welding Ends<\/em>, is the 7th Edition, with an API Monogram Program effective date of October 2, 2025. The project specification should still identify the edition that governs the purchase.<\/div>\n<h2>What Does API 6D Actually Cover?<\/h2>\n<p><strong>API Specification 6D, <em>Specification for Valves<\/em><\/strong>, covers a broader valve family than ball valves alone. The current scope addresses requirements for design, manufacturing, materials, welding, quality control, assembly, testing, marking, documentation and process controls for axial, ball, check, gate and plug valves used within its stated petroleum, natural-gas and hydrogen-gas application scope.<\/p>\n<p>For a standards-level explanation separate from this comparison, see the <a href=\"https:\/\/raymonvalve.com\/api-6d-valves\/\">API 6D standard scope guide<\/a>.<\/p>\n<h3>Product and Application Scope<\/h3>\n<p>For ball-valve procurement, API 6D is frequently encountered in pipeline isolation, transmission systems, terminal service and trunnion-mounted valve applications. Where a project requires a specific API 6D product configuration, the <a href=\"https:\/\/raymonvalve.com\/product\/api-6d-ball-valve\/\">API 6D ball valve product page<\/a> can be used as the commercial product reference, while the project datasheet remains the technical basis for approval.<\/p>\n<p>Frequently specified does not mean automatically required. The owner specification, EPC valve specification, pipeline or piping specification, material requisition and purchase order determine the procurement requirement.<\/p>\n<h3>API 6D Is More Than a Valve Location Label<\/h3>\n<p>A valve can be installed inside a pipeline-related facility while still being controlled by a process piping specification. Likewise, a terminal or plant interface may contain valves for which the owner specifically requires API 6D.<\/p>\n<p>Before selecting the product standard, verify the system boundary, valve function, end connection, bore requirement, pressure class, pressure-temperature basis, materials, seat arrangement, testing and documentation requirements.<\/p>\n<figure class=\"rv-image\"><img decoding=\"async\" title=\"API 6D and API 608 Service Context\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-api-608-pipeline-process-service-context.webp\" alt=\"Pipeline and process piping service context for API 6D and API 608 ball valves\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"engineering-schematic\" \/>\n<figcaption>Example service-context diagram showing why installation location alone does not determine the applicable valve standard.<\/figcaption>\n<\/figure>\n<h2>What Does API 608 Actually Cover?<\/h2>\n<p><strong>API Standard 608, <em>Metal Ball Valves\u2014Flanged, Threaded and Welding Ends<\/em><\/strong>, is specifically a metal ball-valve product standard.<\/p>\n<p>It should not be described as a floating-ball-valve-only standard, a low-pressure-only standard or a lower-grade substitute for API 6D. Those shortcuts turn a scope comparison into an unsupported construction or service claim.<\/p>\n<h3>Where API 608 Commonly Fits<\/h3>\n<p>API 608 is commonly relevant to refinery, petrochemical, chemical-processing, utility, terminal, skid and general industrial isolation applications. The standard designation still does not replace review of pressure-temperature conditions, medium, valve construction, materials, seat and seal system, end connections, testing and documentation.<\/p>\n<div class=\"rv-note\"><strong>Selection boundary:<\/strong> If the project already mandates API 6D or API 608, the supplier should respond to the stated requirement and list any deviation or proposed substitution for technical approval.<\/div>\n<h2>How Do Product Standards, Testing and Project Requirements Work Together?<\/h2>\n<p>A recurring procurement problem is treating one standard number as proof of every performance or qualification requirement. In practice, product requirements, production pressure testing, special qualification, purchaser inspection and order documentation are different layers.<\/p>\n<figure class=\"rv-image\"><img decoding=\"async\" title=\"Ball Valve Standards and Qualification Requirements\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-ball-valve-standards-relationship-diagram.webp\" alt=\"Relationship between API 6D, API 608, pressure testing and separate qualification requirements\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"engineering-schematic\" \/>\n<figcaption>Engineering schematic separating product standards, pressure testing, fire qualification and project-specific requirements.<\/figcaption>\n<\/figure>\n<div class=\"rv-note\"><strong>Specification hierarchy matters:<\/strong> Read the valve product standard together with the governing project specification, piping or pipeline requirements, material requirements, purchaser supplements and applicable inspection or qualification documents. If requirements conflict, the purchase documents should define precedence and the supplier should record deviations for approval.<\/div>\n<p>For the separate boundaries between shell, closure and other production tests, use the <a href=\"https:\/\/raymonvalve.com\/valve-pressure-testing\/\">valve pressure testing requirements guide<\/a>.<\/p>\n<h2>API 6D vs API 608 Design Scope: What Still Has to Be Specified?<\/h2>\n<p>The standard designation is one field on the valve datasheet\u2014not the complete valve specification. Construction, bore, pressure-temperature suitability, materials, seats and actuation still require engineering review.<\/p>\n<h3>Floating vs Trunnion Construction<\/h3>\n<p>Do not infer the ball-support arrangement from the API number alone. The RFQ should identify whether floating or trunnion-mounted construction is required, or whether the supplier may propose a construction subject to technical review.<\/p>\n<p>Ball support affects pressure-load paths, seat behavior, operating torque and actuator inputs. For the dedicated construction comparison, see the <a href=\"https:\/\/raymonvalve.com\/blog\/floating-ball-valve-vs-trunnion-ball-valve\/\">floating vs trunnion ball valve guide<\/a>.<\/p>\n<h3>Bore Requirement<\/h3>\n<div class=\"rv-warning\"><strong>Do not assume that \u201cAPI 6D\u201d automatically means full bore.<\/strong> Where pigging, inspection tools, pressure-loss control or a minimum internal opening is important, state the bore requirement directly on the datasheet and purchase order.<\/div>\n<p>Likewise, an API 608 valve should not automatically be treated as reduced bore. Specify the required flow passage independently where the project depends on pig passage, minimum opening or flow capacity.<\/p>\n<p>For bore-specific engineering tradeoffs, see the <a href=\"https:\/\/raymonvalve.com\/blog\/full-port-vs-reduced-port-ball-valve\/\">full port vs reduced port ball valve guide<\/a>.<\/p>\n<div class=\"rv-field-note\"><strong>Typical RFQ mistake:<\/strong> a datasheet states only \u201cAPI 6D ball valve\u201d and the commercial bids are compared before the required bore is defined. One supplier may quote a different flow passage from another while both reference the same product standard. The correction is to put the required bore or minimum passage on the RFQ and verify it on the supplier drawing before commercial normalization.<\/div>\n<h3>Pressure-Temperature Rating<\/h3>\n<p>Pressure class is not a fixed service pressure. Final pressure-temperature suitability depends on the applicable rating basis, material group, temperature and the specific valve construction. Normal operating pressure also does not replace design pressure.<\/p>\n<p>The review should include design pressure, design temperature, minimum temperature where relevant, body and pressure-boundary materials, bolting, seat and seal materials, end connection and any project-specific limitations.<\/p>\n<h2>API 6D vs API 608 Testing: What Must the Buyer Verify?<\/h2>\n<p>The useful procurement question is not which standard has the \u201cbetter\u201d test. The buyer should determine which production tests, qualification requirements, witness points and acceptance criteria apply to the actual supplied valve.<\/p>\n<figure class=\"rv-image\"><img loading=\"lazy\" decoding=\"async\" title=\"API 6D vs API 608 Testing Scope Matrix\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-vs-api-608-testing-scope-matrix.webp\" alt=\"API 6D vs API 608 ball valve testing scope and separate qualification requirements\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"engineering-matrix\" \/>\n<figcaption>Testing matrix showing production pressure testing versus separate fire-safe, emissions and project-specific requirements.<\/figcaption>\n<\/figure>\n<h3>Production Pressure Testing<\/h3>\n<p>Ball-valve procurement normally requires defined shell\/body and seat\/closure testing within the applicable specification framework. The RFQ should identify the governing test basis, acceptance requirements and any purchaser witness or hold points.<\/p>\n<p>A shell test primarily addresses the pressure boundary under the specified test conditions. A closure or seat test addresses shut-off performance under its specified conditions. Passing one test does not prove every other performance requirement.<\/p>\n<div class=\"rv-note\"><strong>Important:<\/strong> production pressure testing, design qualification testing and purchaser inspection are different activities. A routine shell or seat test does not by itself prove fire-safe, fugitive-emission, cryogenic, sour-service or other special-service qualification.<\/div>\n<h3>Fire-Safe and Fugitive-Emission Requirements Are Separate Evidence Questions<\/h3>\n<p>An API 6D or API 608 designation alone should not be presented as proof that every offered valve configuration has the required fire-safe or fugitive-emission qualification. Where those requirements apply, the purchaser should state the applicable basis and review evidence relevant to the offered design.<\/p>\n<div class=\"rv-field-note\"><strong>Typical technical-bid issue:<\/strong> a supplier attaches a generic fire-test certificate while the quotation does not clearly identify whether the evidence applies to the offered construction, seat system or relevant design range. The certificate should not be accepted only because the standard number appears on the cover page. First map the submitted evidence to the actual offered configuration and project requirement.<\/div>\n<h3>Sour, Hydrogen, Cryogenic and Other Special Service<\/h3>\n<p>The product-standard designation is not a substitute for a complete service review. Where applicable, the purchaser may still need to confirm medium composition, H<sub>2<\/sub>S or hydrogen conditions, temperature, material requirements, hardness or heat-treatment controls, nonmetallic compatibility, NDE, PMI and project-specific qualification requirements.<\/p>\n<h2>API 6D vs API 608 Selection Matrix<\/h2>\n<div class=\"raymonvalve-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"API 6D versus API 608 selection matrix\">\n<table class=\"rv-table\">\n<thead>\n<tr>\n<th scope=\"col\">Project Condition<\/th>\n<th scope=\"col\">API 6D Direction<\/th>\n<th scope=\"col\">API 608 Direction<\/th>\n<th scope=\"col\">Procurement Check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transmission \/ pipeline isolation<\/td>\n<td>Common specification context<\/td>\n<td>Use where permitted by project requirements<\/td>\n<td>Owner \/ pipeline specification<\/td>\n<\/tr>\n<tr>\n<td>Pigging or minimum passage requirement<\/td>\n<td>Relevant to many projects, but bore still must be specified<\/td>\n<td>Verify the actual offered geometry<\/td>\n<td>Required bore + supplier drawing<\/td>\n<\/tr>\n<tr>\n<td>Process plant isolation<\/td>\n<td>May apply when specified<\/td>\n<td>Common specification context<\/td>\n<td>Piping class \/ valve specification<\/td>\n<\/tr>\n<tr>\n<td>Large trunnion ball valve<\/td>\n<td>Common procurement context<\/td>\n<td>Verify the applicable scope and offered construction<\/td>\n<td>Construction + seat arrangement<\/td>\n<\/tr>\n<tr>\n<td>Fire-safe duty<\/td>\n<td>Separate applicable evidence required<\/td>\n<td>Separate applicable evidence required<\/td>\n<td>Qualification basis + offered-design evidence<\/td>\n<\/tr>\n<tr>\n<td>Fugitive-emission requirement<\/td>\n<td>Specify separately where required<\/td>\n<td>Specify separately where required<\/td>\n<td>Qualification basis + acceptance criteria<\/td>\n<\/tr>\n<tr>\n<td>Sour service<\/td>\n<td>Standard designation alone is insufficient<\/td>\n<td>Standard designation alone is insufficient<\/td>\n<td>Environment + material + hardness review<\/td>\n<\/tr>\n<tr>\n<td>Cryogenic service<\/td>\n<td>Project-specific review required<\/td>\n<td>Project-specific review required<\/td>\n<td>Material + seat\/seal + qualification review<\/td>\n<\/tr>\n<tr>\n<td>Hydrogen service<\/td>\n<td>Confirm the applicable API 6D and project requirements<\/td>\n<td>Do not infer suitability from API 608 alone<\/td>\n<td>Material + sealing + project specification<\/td>\n<\/tr>\n<tr>\n<td>Actuated isolation valve<\/td>\n<td>Valve standard does not size the actuator<\/td>\n<td>Valve standard does not size the actuator<\/td>\n<td>Torque data + differential pressure + sizing basis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Can a Ball Valve Meet Both API 6D and API 608?<\/h2>\n<p>A particular valve design may potentially satisfy applicable requirements associated with both standards, but dual compliance should never be assumed from appearance, catalog wording or a quotation line that simply states \u201cAPI 6D \/ API 608.\u201d<\/p>\n<div class=\"rv-checklist\">\n<h3>Five Questions Before Accepting \u201cAPI 6D \/ API 608\u201d in a Quotation<\/h3>\n<ol>\n<li><strong>Which edition applies?<\/strong> Confirm the exact edition required by the project and offered by the supplier.<\/li>\n<li><strong>What valve configuration is actually offered?<\/strong> Confirm floating or trunnion construction, body design, bore, end connection, seat system and materials.<\/li>\n<li><strong>Which requirements are included in the quoted scope?<\/strong> Separate product-standard requirements from pressure testing, special qualification, NDE, PMI and purchaser inspection.<\/li>\n<li><strong>What evidence will be supplied?<\/strong> Identify drawings, material records, test reports, qualification records and final inspection documents.<\/li>\n<li><strong>What deviations exist?<\/strong> Require exceptions, substitutions and exclusions to be listed before technical approval.<\/li>\n<\/ol>\n<\/div>\n<p>The engineering question is whether the <strong>specific offered valve<\/strong> satisfies the adopted purchase specification\u2014not whether two standard numbers can be printed on the datasheet.<\/p>\n<h2>Common API 6D vs API 608 Specification Mistakes<\/h2>\n<h3>1. Selecting the Standard Only From Valve Location<\/h3>\n<p>\u201cPipeline\u201d and \u201cprocess plant\u201d are useful context, but neither label replaces the governing project specification.<\/p>\n<h3>2. Assuming API 6D Automatically Means Full Bore<\/h3>\n<p>State the bore or minimum flow-passage requirement whenever pigging, inspection tools or flow area matter.<\/p>\n<h3>3. Treating API 6D as Automatic Proof of DBB or DIB Function<\/h3>\n<p>DBB\/DIB functionality, seat directionality and cavity-pressure behavior depend on the actual valve construction and the specified isolation duty. Do not approve an isolation function from the API 6D designation alone.<\/p>\n<h3>4. Treating the Product Standard as Fire-Safe Certification<\/h3>\n<p>Where fire-safe qualification is required, review the applicable qualification basis and evidence for the offered design.<\/p>\n<h3>5. Ignoring the Standard Edition<\/h3>\n<p>Record the governing edition in the RFQ or purchase specification where required. A quotation that identifies only the standard number can leave a material technical ambiguity.<\/p>\n<h3>6. Comparing Price Before Testing and Documentation Are Normalized<\/h3>\n<p>Two suppliers can reference the same product standard while including different NDE, PMI, witness points, qualification evidence and final-document packages. Those differences should be closed before a commercial comparison is treated as equivalent.<\/p>\n<h2>What Should Be Included in an API 6D or API 608 Ball Valve RFQ?<\/h2>\n<figure class=\"rv-image\"><img loading=\"lazy\" decoding=\"async\" title=\"API 6D and API 608 Ball Valve RFQ Checklist\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-api-608-ball-valve-rfq-checklist.webp\" alt=\"API 6D and API 608 ball valve RFQ checklist for engineering and procurement\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"engineering-checklist\" \/>\n<figcaption>RFQ checklist for standard edition, valve construction, bore, materials, testing, actuation and documentation.<\/figcaption>\n<\/figure>\n<div class=\"rv-checklist\">\n<h3>Service and Design Data<\/h3>\n<ul>\n<li>Valve tag, function and governing project specification<\/li>\n<li>Medium, composition, phase and solids where relevant<\/li>\n<li>Normal and design pressure<\/li>\n<li>Normal, design maximum and minimum temperature where applicable<\/li>\n<li>NPS \/ DN and required pressure class or PN<\/li>\n<li>API 6D or API 608 and the required edition<\/li>\n<li>Floating or trunnion construction<\/li>\n<li>Required bore or minimum flow passage<\/li>\n<li>End connection and dimensional requirement<\/li>\n<li>Body construction and face-to-face \/ end-to-end requirement where applicable<\/li>\n<\/ul>\n<h3>Materials, Seats and Sealing<\/h3>\n<ul>\n<li>Body, ball, stem and other project-controlled materials<\/li>\n<li>Seat material and seat arrangement<\/li>\n<li>Packing, body seals and gaskets<\/li>\n<li>Coating or overlay where required<\/li>\n<li>Required isolation function where DBB\/DIB is specified<\/li>\n<li>Closure leakage or shut-off requirement<\/li>\n<li>Cavity-pressure management requirement where relevant<\/li>\n<li>Sour-service, low-temperature, cryogenic or other special-service controls<\/li>\n<\/ul>\n<h3>Actuation<\/h3>\n<ul>\n<li>Manual, gear, pneumatic, hydraulic or electric operation<\/li>\n<li>Valve torque data for the specified operating condition<\/li>\n<li>Maximum differential pressure relevant to operation<\/li>\n<li>Required operating time and operating frequency<\/li>\n<li>Air or electrical supply<\/li>\n<li>Required fail position where applicable<\/li>\n<li>Project actuator sizing margin basis<\/li>\n<\/ul>\n<h3>Testing and Inspection<\/h3>\n<ul>\n<li>Shell\/body pressure testing<\/li>\n<li>Seat\/closure testing<\/li>\n<li>Applicable inspection\/test standard and acceptance criteria<\/li>\n<li>Fire-safe qualification where required<\/li>\n<li>Fugitive-emission qualification where required<\/li>\n<li>NDE and PMI scope<\/li>\n<li>Third-party inspection<\/li>\n<li>Purchaser witness and hold points<\/li>\n<\/ul>\n<h3>Documentation<\/h3>\n<ul>\n<li>General arrangement drawing<\/li>\n<li>Sectional drawing where required<\/li>\n<li>Datasheet and bill of materials<\/li>\n<li>MTC \/ material records required by the purchase specification<\/li>\n<li>Pressure-test reports<\/li>\n<li>Applicable qualification records<\/li>\n<li>ITP \/ QAP where required<\/li>\n<li>Actuator sizing information where applicable<\/li>\n<li>Technical deviation schedule<\/li>\n<\/ul>\n<\/div>\n<h2>How Should Suppliers Be Compared?<\/h2>\n<p>Normalize the technical scope before comparing commercial price. Two suppliers can quote the same standard number while offering materially different construction, inspection, testing and document packages.<\/p>\n<h3>Evidence Should Match the Specific Offered Valve<\/h3>\n<p>A generic company certificate, catalog statement or previous test report should not automatically be treated as evidence for every offered valve configuration. Where project approval depends on design qualification, materials or a special test, confirm that the evidence is applicable to the offered design and the stated project requirement.<\/p>\n<div class=\"raymonvalve-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Supplier technical quotation normalization table\">\n<table class=\"rv-table\">\n<thead>\n<tr>\n<th scope=\"col\">Review Item<\/th>\n<th scope=\"col\">Supplier Offer<\/th>\n<th scope=\"col\">Evidence to Review<\/th>\n<th scope=\"col\">Typical Deviation Risk<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product standard \/ edition<\/td>\n<td>API 6D or API 608 + edition<\/td>\n<td>Datasheet \/ technical compliance statement<\/td>\n<td>Edition omitted or different from project requirement<\/td>\n<\/tr>\n<tr>\n<td>Valve construction<\/td>\n<td>Floating \/ trunnion \/ body construction<\/td>\n<td>GA \/ sectional drawing<\/td>\n<td>Construction differs from RFQ assumption<\/td>\n<\/tr>\n<tr>\n<td>Bore<\/td>\n<td>Actual offered flow passage<\/td>\n<td>Datasheet \/ approved drawing<\/td>\n<td>Reduced opening quoted where minimum bore is required<\/td>\n<\/tr>\n<tr>\n<td>Materials<\/td>\n<td>Body \/ ball \/ stem \/ seats \/ seals<\/td>\n<td>BOM + required material records<\/td>\n<td>Substitution or material scope not clearly declared<\/td>\n<\/tr>\n<tr>\n<td>Seat arrangement<\/td>\n<td>Offered seat system and sealing direction<\/td>\n<td>Sectional drawing \/ datasheet<\/td>\n<td>Isolation function inferred rather than demonstrated<\/td>\n<\/tr>\n<tr>\n<td>Pressure testing<\/td>\n<td>Included test scope<\/td>\n<td>Procedure \/ test report<\/td>\n<td>Purchaser-specific test omitted<\/td>\n<\/tr>\n<tr>\n<td>Fire-safe \/ special qualification<\/td>\n<td>Where required by project<\/td>\n<td>Applicable qualification evidence<\/td>\n<td>Generic evidence does not map to offered design<\/td>\n<\/tr>\n<tr>\n<td>NDE \/ PMI<\/td>\n<td>Project-required scope<\/td>\n<td>Procedure \/ inspection record<\/td>\n<td>Excluded, limited or priced separately<\/td>\n<\/tr>\n<tr>\n<td>Actuation<\/td>\n<td>Manual \/ gear \/ automated package<\/td>\n<td>Valve torque + actuator sizing basis<\/td>\n<td>Actuator selected without the required operating case<\/td>\n<\/tr>\n<tr>\n<td>Documentation<\/td>\n<td>Final document package<\/td>\n<td>Document index \/ ITP \/ MDR requirement<\/td>\n<td>Required records excluded from commercial scope<\/td>\n<\/tr>\n<tr>\n<td>Technical deviations<\/td>\n<td>Supplier exceptions<\/td>\n<td>Deviation schedule<\/td>\n<td>Exception hidden in quotation notes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rv-field-note\"><strong>Typical document-review problem:<\/strong> the supplier datasheet, sectional drawing and test procedure are prepared at different stages and do not describe the same bore, seat arrangement or test scope. The reviewer should reconcile those documents before manufacturing or FAT rather than relying on the standard designation to resolve the inconsistency later.<\/div>\n<h2>How to Choose Between API 6D and API 608<\/h2>\n<ol class=\"rv-steps\">\n<li><strong>Identify the governing project requirement.<\/strong><br \/>Start with the owner specification, EPC valve specification, piping or pipeline specification, material requisition and purchase documents.<\/li>\n<li><strong>Check the standard scope against the proposed valve.<\/strong><br \/>Confirm valve type, size, pressure class, construction, bore, end connection and intended service.<\/li>\n<li><strong>Add project-specific requirements.<\/strong><br \/>Define materials, shut-off duty, fire-safe, emissions, sour-service, hydrogen, cryogenic, testing, NDE, PMI and actuation requirements where applicable.<\/li>\n<li><strong>Normalize supplier evidence.<\/strong><br \/>Compare the offered edition, construction, materials, bore, tests, qualification evidence, drawings and deviations before technical approval and price comparison.<\/li>\n<\/ol>\n<figure class=\"rv-image\"><img loading=\"lazy\" decoding=\"async\" title=\"API 6D vs API 608 Ball Valve Selection Flowchart\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-vs-api-608-selection-flowchart.webp\" alt=\"API 6D vs API 608 ball valve selection flowchart\" width=\"1200\" height=\"900\" data-image-status=\"live-verified\" data-source-type=\"decision-flowchart\" \/>\n<figcaption>Example decision path for selecting the applicable ball valve standard from project specification, service and testing requirements.<\/figcaption>\n<\/figure>\n<h2>Final Selection Takeaway<\/h2>\n<p>API 6D and API 608 address related but different ball-valve specification needs. API 6D has the broader multi-valve scope, while API 608 is specifically a metal ball-valve standard. Neither should be selected simply because one is perceived as stricter, more expensive or automatically suitable for a particular installation location.<\/p>\n<p>For an actual project, combine the adopted product standard with the required construction, bore, pressure-temperature rating basis, materials, seats, shut-off requirement, testing, special qualification, actuation, inspection and documentation.<\/p>\n<div class=\"rv-cta\">\n<h2>Request an API 6D \/ API 608 Ball Valve Specification Review<\/h2>\n<p>Send the governing valve or piping specification together with the medium, design pressure and temperature, size, pressure class, end connection, bore requirement, valve construction, materials, seat arrangement, shut-off requirement, actuation method and required inspection or qualification scope.<\/p>\n<p>For supplier comparison, also include the required API edition, drawing and document requirements, fire-safe or fugitive-emission requirements, NDE \/ PMI scope and any third-party witness or hold points.<\/p>\n<a class=\"rv-button\" href=\"https:\/\/raymonvalve.com\/contact\/\">Submit Your Valve Datasheet \/ RFQ<\/a><\/div>\n<section class=\"rv-faq\" aria-labelledby=\"rv-faq-title\">\n<h2 id=\"rv-faq-title\">Frequently Asked Questions<\/h2>\n<details>\n<summary>What is the main difference between API 6D and API 608 ball valves?<\/summary>\n<p>API 6D covers a broader family of valve products, including ball valves, while API 608 is specifically a metal ball-valve standard. The correct project requirement still depends on the governing specification, valve configuration, service conditions, testing and documentation.<\/p>\n<\/details><details>\n<summary>Is API 6D required for every pipeline ball valve?<\/summary>\n<p>No. API 6D is widely used in pipeline valve procurement, but the applicable standard should be established by the owner, EPC, pipeline or piping specification and purchase documents rather than installation location alone.<\/p>\n<\/details><details>\n<summary>Is an API 6D ball valve always full bore?<\/summary>\n<p>No. Do not infer the required bore from the standard designation alone. Where full opening, pigging or minimum internal diameter matters, state the requirement in the datasheet and verify the offered bore on the supplier drawing.<\/p>\n<\/details><details>\n<summary>Can a ball valve meet both API 6D and API 608 requirements?<\/summary>\n<p>A particular design may satisfy applicable requirements associated with both standards, but the buyer should verify the editions, product scope, offered construction, testing, qualification evidence and documentation rather than assume dual compliance from a catalog statement.<\/p>\n<\/details><details>\n<summary>Does API 6D or API 608 automatically mean a ball valve is fire-safe?<\/summary>\n<p>No. Where fire-safe performance is required, the project should identify the applicable qualification basis and the supplier should provide evidence relevant to the offered valve design.<\/p>\n<\/details><details>\n<summary>What information should be included in an API 6D or API 608 ball valve RFQ?<\/summary>\n<p>Include the governing specification and edition, valve function, medium, design pressure and temperature, size, class, end connection, construction, bore, materials, seat arrangement, shut-off requirement, testing, inspection, actuation and required documentation.<\/p>\n<\/details><\/section>\n<div class=\"rv-related\">\n<h2>Related Raymon Valve Resources<\/h2>\n<ul>\n<li><a href=\"https:\/\/raymonvalve.com\/product\/api-6d-ball-valve\/\">API 6D Ball Valve Product Configurations<\/a><\/li>\n<li><a href=\"https:\/\/raymonvalve.com\/valve-pressure-testing\/\">Industrial Valve Pressure Testing Guide<\/a><\/li>\n<\/ul>\n<\/div>\n<div class=\"rv-references\">\n<h2>Official Standards References<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.api.org\/-\/media\/Files\/Certification\/Monogram-APIQR\/0_API-Monogram-APIQR\/Advisories-Updates\/Addenda-Errata\/API_Specification_6D_25th_Edition_Addendum_2_20240910.pdf\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"> API Specification 6D, 25th Edition \u2014 Addendum 2 Scope Update <\/a><\/li>\n<li><a href=\"https:\/\/www.api.org\/-\/media\/Files\/Certification\/Monogram-APIQR\/0_API-Monogram-APIQR\/Advisories-Updates\/Updates\/API_Standard_608_7th_Edition_Update_20251006.pdf\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"> API Standard 608, 7th Edition \u2014 API Monogram Program Update <\/a><\/li>\n<li><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-34-valves-flanged-threaded-welding-end\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"> ASME B16.34-2025 \u2014 Valves\u2014Flanged, Threaded, and Welding End <\/a><\/li>\n<\/ul>\n<\/div>\n<div class=\"rv-engineering-note\"><strong>Engineering Note:<\/strong> This article supports preliminary specification, RFQ preparation and technical-bid review. It does not replace the applicable purchased standard, project specification, valve datasheet, manufacturer design data or responsible-engineer approval. Standard editions, purchaser options, pressure-temperature ratings, material and sealing requirements, qualification scope and inspection requirements should be confirmed for each project. Product-specific conformity should be supported by documentation and test records applicable to the actual supplied configuration.<\/div>\n<\/div>\n<\/article>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"TechArticle\",\n  \"headline\":\"API 6D vs API 608 Ball Valve: Pipeline Service, Design Scope, Testing and Selection\",\n  \"description\":\"Compare API 6D vs API 608 ball valves by standard scope, pipeline and process service, construction, bore, testing, supplier evidence and RFQ requirements.\",\n  \"mainEntityOfPage\":{\n    \"@type\":\"WebPage\",\n    \"@id\":\"https:\/\/raymonvalve.com\/api-6d-vs-api-608-ball-valve\/\"\n  },\n  \"image\":[\n    \"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/api-6d-vs-api-608-ball-valve-comparison.webp\"\n  ],\n  \"author\":{\n    \"@type\":\"Organization\",\n    \"name\":\"Raymon Valve\"\n  },\n  \"publisher\":{\n    \"@type\":\"Organization\",\n    \"name\":\"Raymon Valve\",\n    \"url\":\"https:\/\/raymonvalve.com\/\"\n  }\n}\n<\/script> <script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"What is the main difference between API 6D and API 608 ball valves?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"API 6D covers a broader family of valve products, including ball valves, while API 608 is specifically a metal ball-valve standard. The correct project requirement still depends on the governing specification, valve configuration, service conditions, testing and documentation.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Is API 6D required for every pipeline ball valve?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"No. API 6D is widely used in pipeline valve procurement, but the applicable standard should be established by the owner, EPC, pipeline or piping specification and purchase documents rather than installation location alone.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Is an API 6D ball valve always full bore?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"No. Do not infer the required bore from the standard designation alone. Where full opening, pigging or minimum internal diameter matters, state the requirement in the datasheet and verify the offered bore on the supplier drawing.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Can a ball valve meet both API 6D and API 608 requirements?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"A particular design may satisfy applicable requirements associated with both standards, but the buyer should verify the editions, product scope, offered construction, testing, qualification evidence and documentation rather than assume dual compliance from a catalog statement.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"Does API 6D or API 608 automatically mean a ball valve is fire-safe?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"No. Where fire-safe performance is required, the project should identify the applicable qualification basis and the supplier should provide evidence relevant to the offered valve design.\"\n      }\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"What information should be included in an API 6D or API 608 ball valve RFQ?\",\n      \"acceptedAnswer\":{\n        \"@type\":\"Answer\",\n        \"text\":\"Include the governing specification and edition, valve function, medium, design pressure and temperature, size, class, end connection, construction, bore, materials, seat arrangement, shut-off requirement, testing, inspection, actuation and required documentation.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>API 6D and API 608 are both used to specify metal ball valves, but neither standard [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-14716","post","type-post","status-publish","format-standard","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/posts\/14716","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/comments?post=14716"}],"version-history":[{"count":4,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/posts\/14716\/revisions"}],"predecessor-version":[{"id":14720,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/posts\/14716\/revisions\/14720"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/media?parent=14716"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/categories?post=14716"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/tags?post=14716"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}