{"id":10950,"date":"2026-07-27T21:50:23","date_gmt":"2026-07-27T13:50:23","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?post_type=product&#038;p=10950"},"modified":"2026-07-29T17:10:34","modified_gmt":"2026-07-29T09:10:34","slug":"electric-gate-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/es\/product\/electric-gate-valve\/","title":{"rendered":"V\u00e1lvula de compuerta el\u00e9ctrica"},"content":{"rendered":"<div class=\"rv-product-content rvp-content\">\n<section id=\"overview\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Engineering scope<\/div>\n<h2>Electric Gate Valve selection starts with the service duty<\/h2>\n<p class=\"rvp-lead\">A Electric Gate Valve is evaluated for linear full-open or full-closed isolation. A gate moves across the flow path. Wedge or slab geometry, seat arrangement, bonnet construction, stem loading and body cavity design control sealing and operability.<\/p>\n<p>Before quoting this configuration, close electric actuator torque\/thrust, duty rating, power, controls and fail strategy and record all process, mechanical, operating and documentation assumptions.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Electric<\/h3>\n<p>Electric actuator torque\/thrust, duty rating, power, controls and fail strategy. State power supply, control signal, duty cycle, travel time, enclosure, hazardous area, manual override and fail requirement.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Application envelope<\/h3>\n<p>Confirm every pressure, temperature, differential-pressure and cycling case for this Electric Gate Valve.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Installed interface<\/h3>\n<p>Verify ends, bore, flow direction, orientation, operator envelope, loads and maintenance access.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Order-specific boundary<\/h3>\n<p>Published information supports initial screening; final size, class, materials, trim, operation, tests and documents are fixed in approved order records.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"specifications\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Specification workflow<\/div>\n<h2>Close the questions hidden behind the product description<\/h2>\n<p class=\"rvp-lead\">Record the question, accepted answer and proof so the Electric Gate Valve proposal can be audited across disciplines.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Review area<\/th>\n<th>Engineering question<\/th>\n<th>Required record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Gate construction<\/td>\n<td>Wedge, parallel slide, slab or knife designs serve different pressure, temperature and solids duties.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<tr>\n<td>Bonnet and stem<\/td>\n<td>Bolted, welded or pressure-seal bonnets and rising or non-rising stems affect maintenance and thrust.<\/td>\n<td>Name the controlling document, responsible reviewer and inspection or calculation record.<\/td>\n<\/tr>\n<tr>\n<td>Bore and cavity<\/td>\n<td>Minimum bore, pigging, equalization, vents and drains must be defined where applicable.<\/td>\n<td>State the measurable requirement and connect it to a drawing, procedure or test result.<\/td>\n<\/tr>\n<tr>\n<td>Operating duty<\/td>\n<td>Gate valves normally require full-open\/full-closed operation; throttling exposure needs a separate review.<\/td>\n<td>Resolve the open point before release and retain tag-specific evidence in the final dossier.<\/td>\n<\/tr>\n<tr>\n<td>Electric<\/td>\n<td>State power supply, control signal, duty cycle, travel time, enclosure, hazardous area, manual override and fail requirement.<\/td>\n<td>Resolve the open point before release and retain tag-specific evidence in the final dossier.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\">Record exact standard designations and contract editions; resolve scope gaps and purchaser options before manufacture.<\/p>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"rvp-section rvp-dark\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Application boundaries<\/div>\n<h2>Service conditions that can change or reject the selection<\/h2>\n<p>Avoid prolonged throttling unless the selected construction is explicitly qualified for it; partial opening can damage gates and seats. The final decision must cover system interactions, end-of-life loads, degradation and how failure will be detected or contained.<\/p>\n<div class=\"rvp-checks\">\n<div class=\"rvp-check\">Fluid composition plus minimum, normal, maximum, startup and upset cases for the Electric Gate Valve<\/div>\n<div class=\"rvp-check\">Isolation\/control\/non-return function, frequency, directionality and measurable shutoff acceptance<\/div>\n<div class=\"rvp-check\">Pressure class, size, end connection, face-to-face and piping-interface requirements<\/div>\n<div class=\"rvp-check\">Body, trim, seat, packing, bolting, lining or coating materials as applicable<\/div>\n<div class=\"rvp-check\">Manual or actuated operation, maximum load, fail action, speed, utilities and accessories<\/div>\n<div class=\"rvp-check\">Applicable standards, pressure tests, special tests, inspection points and final documents<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Evidence and quality<\/div>\n<h2>Use order records\u2014not generic certificates\u2014for acceptance<\/h2>\n<p class=\"rvp-lead\">Generic examples may explain capability but cannot close an order requirement unless they apply to the delivered valve. Use the <a href=\"\/valve-standards\/\">valve standards guide<\/a> to separate product, rating, dimensional, end-connection and test scope.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Design basis<\/h3>\n<p>Approved datasheet, drawing, bill of materials, rating basis and documented deviations.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Material identity<\/h3>\n<p>Tag-to-component material mapping with certificates, processing records and identity checks.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Inspection and tests<\/h3>\n<p>Inspection releases, controlled test methods, instrument identity, measurements and final acceptance.<\/p>\n<\/div>\n<\/div>\n<p>Electric fail action may require stored energy or an external system; loss-of-power behavior must be explicit.<\/p>\n<p>Do not infer certification or guaranteed performance from this page. Accept only the order-specific evidence required by the purchaser.<\/p>\n<\/div>\n<\/section>\n<section id=\"rfq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">RFQ checklist<\/div>\n<h2>RFQ inputs that remove avoidable assumptions<\/h2>\n<p>Provide a controlled valve list or datasheet covering every operating case, interface, material, operation, standard, inspection, test and document requirement.<\/p>\n<p>For a Electric Gate Valve, also highlight electric actuator torque\/thrust, duty rating, power, controls and fail strategy. Identify missing inputs and provisional selections so they can be closed before purchase order release.<\/p>\n<div class=\"rvp-cta\">\n<div>\n<h2>Send the service cases for engineering review<\/h2>\n<p>Send the valve list and project requirements. Raymon Valve will identify missing inputs, clarify construction and return an order-specific quotation basis.<\/p>\n<\/div>\n<div class=\"rvp-actions\"><a class=\"rvp-btn rvp-btn-primary\" href=\"\/contact\/\">Submit Your Datasheet<\/a><a class=\"rvp-btn rvp-btn-ghost\" href=\"\/gate-valves\/\">Compare Gate Valve Options<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Related engineering route<\/div>\n<h2>Use the related pages to close remaining decisions<\/h2>\n<div class=\"rvp-grid\"><a class=\"rvp-card\" href=\"\/gate-valves\/\"><\/p>\n<h3>Product family<\/h3>\n<p>Compare the main constructions and selection boundaries in this valve family.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-solutions\/\"><\/p>\n<h3>Project Valve Review<\/h3>\n<p>Resolve interacting pressure, temperature, corrosion, wear or project risks.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-pressure-testing\/\"><\/p>\n<h3>Testing and inspection<\/h3>\n<p>Define pressure-test scope, acceptance, instruments, witness points and records.<\/p>\n<p><\/a><\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-CSS-START --><\/p>\n<style id=\"rvq-quality-css\">.rvq-section{padding:68px 0;font-family:Arial,Helvetica,sans-serif;color:#17233a;line-height:1.7}.rvq-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rvq-intent{background:#f4f7fb}.rvq-trust{background:#fff}.rvq-kicker{color:#07549a;font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rvq-section h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:#0b1731}.rvq-lead{max-width:900px;color:#5c6779;font-size:17px}.rvq-tablewrap{overflow-x:auto;margin-top:28px;border:1px solid #dfe5ee;border-radius:12px;background:#fff}.rvq-table{width:100%;border-collapse:collapse;min-width:760px}.rvq-table th{background:#07549a;color:#fff;text-align:left;padding:15px}.rvq-table td{padding:15px;border-bottom:1px solid #dfe5ee;vertical-align:top}.rvq-table tr:last-child td{border-bottom:0}.rvq-source,.rvq-boundary{margin-top:22px;padding:20px;border-left:5px solid #f3cc18;background:#fff8d8;border-radius:8px}.rvq-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin:25px 0}.rvq-grid>div{border:1px solid #dfe5ee;border-radius:10px;padding:18px;background:#f8fafc}.rvq-grid b,.rvq-grid span{display:block}.rvq-grid b{color:#07549a;margin-bottom:5px}.rvq-grid span{font-size:14px;color:#5c6779}@media(max-width:800px){.rvq-grid{grid-template-columns:1fr 1fr}}@media(max-width:520px){.rvq-wrap{width:min(100% - 28px,1160px)}.rvq-section{padding:50px 0}.rvq-grid{grid-template-columns:1fr}}<\/style>\n<p><!-- RVQ-CSS-END --><!-- RVQ-INTENT-START --><\/p>\n<section class=\"rvq-section rvq-intent\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Task-specific answer<\/div>\n<h2>Convert Electric Gate Valve from a broad request into an auditable engineering decision<\/h2>\n<p class=\"rvq-lead\">This section addresses the decision a visitor is likely trying to complete\u2014not merely the meaning of the page title. Use it to identify required inputs, compare the proposal and specify the record that will prove acceptance.<\/p>\n<div class=\"rvq-tablewrap\">\n<table class=\"rvq-table\">\n<thead>\n<tr>\n<th>Decision<\/th>\n<th>What to do<\/th>\n<th>Evidence to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Problem statement<\/b><\/td>\n<td>For Electric Gate Valve, define the required system outcome, failure consequence and measurable acceptance before choosing hardware.<\/td>\n<td>Functional requirement<\/td>\n<\/tr>\n<tr>\n<td><b>Feasible routes<\/b><\/td>\n<td>Compare at least the practical construction, material, sealing and actuation alternatives, including reasons for rejection.<\/td>\n<td>Option and trade-off matrix<\/td>\n<\/tr>\n<tr>\n<td><b>Boundary conditions<\/b><\/td>\n<td>Check every normal, transient, startup, shutdown, maintenance and utility-loss case that can change the solution.<\/td>\n<td>Approved application data<\/td>\n<\/tr>\n<tr>\n<td><b>Validation<\/b><\/td>\n<td>Connect each claimed benefit to a calculation, drawing, qualification, inspection or package-level test that applies to the order.<\/td>\n<td>Verification and evidence plan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rvq-boundary\"><b>Decision boundary:<\/b> This guidance supports screening and RFQ preparation. Final suitability, compliance and supplied scope require the actual application data, governing jurisdiction, contract documents, approved supplier submittals and tag-linked records.<\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-INTENT-END --><!-- RVQ-TRUST-START --><\/p>\n<section class=\"rvq-section rvq-trust\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Content responsibility &amp; evidence<\/div>\n<h2>How this Electric Gate Valve guide should be used<\/h2>\n<div class=\"rvq-grid\">\n<div><b>Publisher<\/b><span>Raymon Valve technical content team<\/span><\/div>\n<div><b>Purpose<\/b><span>Engineering screening, specification and RFQ preparation<\/span><\/div>\n<div><b>Content update<\/b><span>29 July 2026<\/span><\/div>\n<div><b>Verification level<\/b><span>Topic scope, search intent and evidence boundaries checked<\/span><\/div>\n<\/div>\n<p>This page does not claim that a named person, certificate, qualification, installed project or performance result applies to a future order. Product compliance is confirmed only when the accepted quotation, approved drawing, procedures and final manufacturing\/test records identify the supplied configuration.<\/p>\n<p>Technical requirements and standards can change. Verify the official source, contract edition, project precedence and purchaser options. See our <a href=\"\/technical-content-review-policy\/\">technical content review and evidence policy<\/a>, <a href=\"\/about-us\/\">company information<\/a>, <a href=\"\/valve-inspection\/\">inspection approach<\/a> or <a href=\"\/contact\/\">submit a correction or application question<\/a>.<\/p>\n<\/div>\n<\/section>\n<p><!-- RVQ-TRUST-END --><!-- RVQ-SCHEMA-START --><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"WebPage\",\"name\":\"Electric Gate Valve\",\"url\":\"https:\/\/raymonvalve.com\/product\/electric-gate-valve\/\",\"dateModified\":\"2026-07-29\",\"description\":\"Product selection guide for Electric Gate Valve, with application boundaries, decision inputs and order-specific evidence requirements.\",\"publisher\":{\"@type\":\"Organization\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"isPartOf\":{\"@type\":\"WebSite\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"about\":{\"@type\":\"Thing\",\"name\":\"Electric Gate Valve\"}}<\/script><!-- RVQ-SCHEMA-END --><\/p>\n<section id=\"faq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">FAQ<\/div>\n<h2>Electric Gate Valve questions<\/h2>\n<div class=\"rvp-faq\">\n<details>\n<summary>What information is required to select a Electric Gate Valve?<\/summary>\n<p>Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address electric actuator torque\/thrust, duty rating, power, controls and fail strategy.<\/p>\n<\/details>\n<details>\n<summary>Which standards apply to a Electric Gate Valve?<\/summary>\n<p>The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Electric fail action may require stored energy or an external system; loss-of-power behavior must be explicit.<\/p>\n<\/details>\n<details>\n<summary>How should Electric Gate Valve pressure and leakage testing be specified?<\/summary>\n<p>Define the test configuration and measurable acceptance rather than requesting a generic factory test. Include calibrated instruments, valve position, pressure direction and tag-linked results.<\/p>\n<\/details>\n<details>\n<summary>Can a Electric Gate Valve be supplied with an actuator?<\/summary>\n<p>Where automation is feasible, size from the worst-case valve torque or thrust curve, project margin, fail action, travel time, minimum utility, duty, controls, mounting and package test.<\/p>\n<\/details>\n<details>\n<summary>When should a Electric Gate Valve not be selected?<\/summary>\n<p>Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Avoid prolonged throttling unless the selected construction is explicitly qualified for it; partial opening can damage gates and seats. The alternative should be chosen only after comparing the complete service duty.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What information is required to select a Electric Gate Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address electric actuator torque\/thrust, duty rating, power, controls and fail strategy.\"}}, {\"@type\": \"Question\", \"name\": \"Which standards apply to a Electric Gate Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Electric fail action may require stored energy or an external system; loss-of-power behavior must be explicit.\"}}, {\"@type\": \"Question\", \"name\": \"How should Electric Gate Valve pressure and leakage testing be specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Define the test configuration and measurable acceptance rather than requesting a generic factory test. Include calibrated instruments, valve position, pressure direction and tag-linked results.\"}}, {\"@type\": \"Question\", \"name\": \"Can a Electric Gate Valve be supplied with an actuator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Where automation is feasible, size from the worst-case valve torque or thrust curve, project margin, fail action, travel time, minimum utility, duty, controls, mounting and package test.\"}}, {\"@type\": \"Question\", \"name\": \"When should a Electric Gate Valve not be selected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Avoid prolonged throttling unless the selected construction is explicitly qualified for it; partial opening can damage gates and seats. The alternative should be chosen only after comparing the complete service duty.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>V\u00e1lvula de compuerta el\u00e9ctrica para aislamiento lineal de apertura o cierre total definido por proyecto. La selecci\u00f3n aborda el par\/empuje del actuador el\u00e9ctrico, la clase de servicio, la potencia, los controles y la estrategia de fallo, los materiales, la operaci\u00f3n, las pruebas y la aceptaci\u00f3n documentada antes de la liberaci\u00f3n de la cotizaci\u00f3n.<\/p>","protected":false},"featured_media":5636,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[175],"product_tag":[],"class_list":["post-10950","product","type-product","status-publish","has-post-thumbnail","product_cat-gate-valves","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-gallery-with-no-image","ast-product-tabs-layout-horizontal","ast-qv-on-image","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product\/10950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/comments?post=10950"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/media\/5636"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/media?parent=10950"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_brand?post=10950"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_cat?post=10950"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_tag?post=10950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}