{"id":13571,"date":"2026-07-27T21:51:15","date_gmt":"2026-07-27T13:51:15","guid":{"rendered":"https:\/\/raymonvalve.com\/product\/metal-seated-ball-valve\/"},"modified":"2026-07-27T22:35:06","modified_gmt":"2026-07-27T14:35:06","slug":"metal-seated-ball-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/es\/product\/metal-seated-ball-valve\/","title":{"rendered":"V\u00e1lvula de bola con asiento met\u00e1lico"},"content":{"rendered":"<div class=\"rv-product-content rvp-content\">\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Engineering scope<\/div>\n<h2>Metal Seated Ball Valve selection starts with the service duty<\/h2>\n<p class=\"rvp-lead\">A Metal Seated Ball Valve is evaluated for quarter-turn isolation or characterized rotary control. A bored ball rotates between seats. The selected bore, ball support, seat loading, stem sealing and cavity-relief arrangement determine pressure loss, operating torque and shutoff behavior.<\/p>\n<p>The product name narrows the route but does not complete the specification. Resolve metal seat\/coating pairing for temperature, erosion, solids or cycling duty together with the medium, operating cases, piping interface, maintenance and evidence.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\"><strong>Metal Seated<\/strong><\/p>\n<p>Metal seat\/coating pairing for temperature, erosion, solids or cycling duty. Define leakage criterion, seat and ball\/disc materials, coating process, directionality, cycling and cleaning method.<\/p>\n<\/div>\n<div class=\"rvp-card\"><strong>Order-specific boundary<\/strong><\/p>\n<p>Published information supports initial screening; final size, class, materials, trim, operation, tests and documents are fixed in approved order records.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Specification workflow<\/div>\n<h2>Build the technical requirement before approving the model<\/h2>\n<p class=\"rvp-lead\">The table turns application inputs for Metal Seated Ball Valve into review points and tag-linked evidence.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Review area<\/th>\n<th>Engineering question<\/th>\n<th>Required record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ball support<\/td>\n<td>Floating or trunnion-supported construction must suit size, pressure and differential load.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<tr>\n<td>Bore<\/td>\n<td>Full, reduced or characterized bore must match flow, pigging and pressure-drop requirements.<\/td>\n<td>Resolve the open point before release and retain tag-specific evidence in the final dossier.<\/td>\n<\/tr>\n<tr>\n<td>Seat system<\/td>\n<td>Soft, resilient or metal seating is selected from temperature, media, solids, cycling and leakage criteria.<\/td>\n<td>Name the controlling document, responsible reviewer and inspection or calculation record.<\/td>\n<\/tr>\n<tr>\n<td>Cavity behavior<\/td>\n<td>Pressure relief direction, double-block requirements, vents and drains must be defined.<\/td>\n<td>Name the controlling document, responsible reviewer and inspection or calculation record.<\/td>\n<\/tr>\n<tr>\n<td>Metal Seated<\/td>\n<td>Define leakage criterion, seat and ball\/disc materials, coating process, directionality, cycling and cleaning method.<\/td>\n<td>Resolve the open point before release and retain tag-specific evidence in the final dossier.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\">A standard title alone is not acceptance. Map its scope, edition and required evidence to the valve tag.<\/p>\n<\/div>\n<\/section>\n<section class=\"rvp-section rvp-dark\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Application boundaries<\/div>\n<h2>Application limits to examine before technical approval<\/h2>\n<p>Do not select from line size and pressure class alone; differential pressure, seat load, cavity pressure and operating torque can govern the design. The final decision must cover system interactions, end-of-life loads, degradation and how failure will be detected or contained.<\/p>\n<div class=\"rvp-checks\">\n<div class=\"rvp-check\">Process envelope, contaminants, phase behavior and every case that can govern the Metal Seated Ball Valve<\/div>\n<div class=\"rvp-check\">Required valve function, operating frequency, shutoff criterion and failure consequence<\/div>\n<div class=\"rvp-check\">Piping class, mating ends, bore, installed length, orientation, loads and maintenance clearance<\/div>\n<div class=\"rvp-check\">Corrosion and wear basis with exact body, trim, sealing, bolting, overlay, lining or coating materials<\/div>\n<div class=\"rvp-check\">Manual or actuated operation, maximum load, fail action, speed, utilities and accessories<\/div>\n<div class=\"rvp-check\">Product, rating, dimensions, ends and test requirements plus special qualification and tag-linked evidence<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Evidence and quality<\/div>\n<h2>Make every critical claim traceable to the valve tag<\/h2>\n<p class=\"rvp-lead\">A certificate or report is useful only when its scope traces to the actual tag, materials and configuration. Use the <a href=\"\/valve-standards\/\">valve standards guide<\/a> to separate product, rating, dimensional, end-connection and test scope.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Design basis<\/h3>\n<p>Tag requirements, design review, materials list and approved exception register.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Material identity<\/h3>\n<p>Tag-to-component material mapping with certificates, processing records and identity checks.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Inspection and tests<\/h3>\n<p>Approved ITP, procedures, calibrated instruments, results, witness records and NCR closeout.<\/p>\n<\/div>\n<\/div>\n<p>Metal seated does not automatically mean zero leakage; acceptance must be stated and tested.<\/p>\n<p>Do not infer certification or guaranteed performance from this page. Accept only the order-specific evidence required by the purchaser.<\/p>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">RFQ checklist<\/div>\n<h2>Information needed for a tag-level technical offer<\/h2>\n<p>Provide a controlled valve list or datasheet covering every operating case, interface, material, operation, standard, inspection, test and document requirement.<\/p>\n<p>For a Metal Seated Ball Valve, also highlight metal seat\/coating pairing for temperature, erosion, solids or cycling duty. Identify missing inputs and provisional selections so they can be closed before purchase order release.<\/p>\n<div class=\"rvp-cta\">\n<div>\n<h2>Request a tag-level technical review<\/h2>\n<p>Share the datasheet, line class and evidence scope so open points and deviations can be resolved before order release.<\/p>\n<\/div>\n<div class=\"rvp-actions\"><a class=\"rvp-btn rvp-btn-primary\" href=\"\/contact\/\">Submit Your Datasheet<\/a><a class=\"rvp-btn rvp-btn-ghost\" href=\"\/ball-valves\/\">Compare Ball Valve Options<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Related engineering route<\/div>\n<h2>Continue the selection review<\/h2>\n<div class=\"rvp-grid\"><a class=\"rvp-card\" href=\"\/ball-valves\/\"><\/p>\n<h3>Product family<\/h3>\n<p>Compare the main constructions and selection boundaries in this valve family.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/wear-resistant-working-condition\/\"><\/p>\n<h3>Wear And Solids Review<\/h3>\n<p>Resolve interacting pressure, temperature, corrosion, wear or project risks.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-pressure-testing\/\"><\/p>\n<h3>Testing and inspection<\/h3>\n<p>Define pressure-test scope, acceptance, instruments, witness points and records.<\/p>\n<p><\/a><\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">FAQ<\/div>\n<h2>Metal Seated Ball Valve questions<\/h2>\n<div class=\"rvp-faq\">\n<details>\n<summary>What information is required to select a Metal Seated Ball Valve?<\/summary>\n<p>Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address metal seat\/coating pairing for temperature, erosion, solids or cycling duty.<\/p>\n<\/details>\n<details>\n<summary>Which standards apply to a Metal Seated Ball Valve?<\/summary>\n<p>The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Metal seated does not automatically mean zero leakage; acceptance must be stated and tested.<\/p>\n<\/details>\n<details>\n<summary>How should Metal Seated Ball Valve pressure and leakage testing be specified?<\/summary>\n<p>Define the test configuration and measurable acceptance rather than requesting a generic factory test. Include calibrated instruments, valve position, pressure direction and tag-linked results.<\/p>\n<\/details>\n<details>\n<summary>Can a Metal Seated Ball Valve be supplied with an actuator?<\/summary>\n<p>Where automation is feasible, size from the worst-case valve torque or thrust curve, project margin, fail action, travel time, minimum utility, duty, controls, mounting and package test.<\/p>\n<\/details>\n<details>\n<summary>When should a Metal Seated Ball Valve not be selected?<\/summary>\n<p>Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not select from line size and pressure class alone; differential pressure, seat load, cavity pressure and operating torque can govern the design. The alternative should be chosen only after comparing the complete service duty.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What information is required to select a Metal Seated Ball Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address metal seat\/coating pairing for temperature, erosion, solids or cycling duty.\"}}, {\"@type\": \"Question\", \"name\": \"Which standards apply to a Metal Seated Ball Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Metal seated does not automatically mean zero leakage; acceptance must be stated and tested.\"}}, {\"@type\": \"Question\", \"name\": \"How should Metal Seated Ball Valve pressure and leakage testing be specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Define the test configuration and measurable acceptance rather than requesting a generic factory test. Include calibrated instruments, valve position, pressure direction and tag-linked results.\"}}, {\"@type\": \"Question\", \"name\": \"Can a Metal Seated Ball Valve be supplied with an actuator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Where automation is feasible, size from the worst-case valve torque or thrust curve, project margin, fail action, travel time, minimum utility, duty, controls, mounting and package test.\"}}, {\"@type\": \"Question\", \"name\": \"When should a Metal Seated Ball Valve not be selected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not select from line size and pressure class alone; differential pressure, seat load, cavity pressure and operating torque can govern the design. The alternative should be chosen only after comparing the complete service duty.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>V\u00e1lvula de bola con asiento met\u00e1lico para aislamiento de giro de cuarto de vuelta o control rotativo caracterizado definido por el proyecto. La selecci\u00f3n aborda la combinaci\u00f3n de asiento\/recubrimiento met\u00e1lico para temperatura, erosi\u00f3n, s\u00f3lidos o servicio c\u00edclico, materiales, operaci\u00f3n, pruebas y aceptaci\u00f3n documentada antes de la liberaci\u00f3n de la cotizaci\u00f3n.<\/p>","protected":false},"featured_media":12704,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[],"product_tag":[],"class_list":["post-13571","product","type-product","status-publish","has-post-thumbnail","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-gallery-with-no-image","ast-product-tabs-layout-horizontal","ast-qv-on-image","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product\/13571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/comments?post=13571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/media\/12704"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/media?parent=13571"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_brand?post=13571"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_cat?post=13571"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/es\/wp-json\/wp\/v2\/product_tag?post=13571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}