{"id":1312,"date":"2022-08-08T16:40:59","date_gmt":"2022-08-08T08:40:59","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?page_id=1312"},"modified":"2026-07-27T18:21:41","modified_gmt":"2026-07-27T10:21:41","slug":"valve-cryogenic-testing","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/fr\/valve-cryogenic-testing\/","title":{"rendered":"Tests et qualification des vannes cryog\u00e9niques"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1312\" class=\"elementor elementor-1312\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eae2f140 e-con-full e-flex e-con e-parent\" data-id=\"eae2f140\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-06af275b elementor-widget elementor-widget-html\" data-id=\"06af275b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>:root{--rv-navy:#0b1731;--rv-navy2:#101f43;--rv-blue:#1f29bd;--rv-yellow:#f3cc18;--rv-ink:#16213a;--rv-line:#dce3ee}.rv-cat{font-family:Geologica,Arial,sans-serif;color:var(--rv-ink);font-size:16px;line-height:1.72;background:#fff;width:100vw;margin-left:calc(50% - 50vw)}.rv-cat *{box-sizing:border-box}.rv-wrap{width:min(1180px,calc(100% - 40px));margin:auto}.rv-section{padding:84px 0}.rv-kicker{font-size:12px;letter-spacing:.14em;text-transform:uppercase;font-weight:800;color:var(--rv-blue);margin:0 0 10px}.rv-title{font-size:clamp(34px,5vw,60px);line-height:1.08;margin:0 0 22px;color:#fff;max-width:900px}.rv-h2{font-size:clamp(28px,4vw,42px);line-height:1.16;margin:0 0 18px}.rv-lead{font-size:18px;max-width:820px;color:#526079;margin:0}.rv-hero{position:relative;isolation:isolate;background:linear-gradient(100deg,rgba(7,18,42,.98),rgba(13,32,74,.91) 60%,rgba(24,42,81,.74)),url('https:\/\/raymonvalve.com\/wp-content\/uploads\/2022\/10\/IMG_2110-01-2-1.jpeg') center\/cover no-repeat;padding:112px 0 96px;overflow:hidden}.rv-hero:after{content:\"\";position:absolute;z-index:-1;width:430px;height:430px;border:1px solid rgba(255,255,255,.12);border-radius:50%;right:-120px;top:-170px;box-shadow:0 0 0 80px rgba(255,255,255,.03),0 0 0 160px rgba(255,255,255,.02)}.rv-crumb{color:#b7c5e6;font-size:13px;margin-bottom:24px}.rv-crumb a{color:#fff;text-decoration:none}.rv-hero p{max-width:780px;color:#dbe5fa;font-size:18px;margin:0 0 30px}.rv-actions{display:flex;gap:12px;flex-wrap:wrap}.rv-btn{display:inline-flex;padding:13px 20px;border-radius:6px;text-decoration:none;font-weight:800;font-size:14px;border:1px solid transparent}.rv-primary{background:var(--rv-yellow);color:#111a31}.rv-ghost{border-color:#aebbd7;color:#fff}.rv-pills{display:flex;gap:10px;flex-wrap:wrap;margin-top:36px}.rv-pill{padding:8px 12px;border:1px solid rgba(255,255,255,.18);background:rgba(255,255,255,.06);border-radius:999px;color:#dce7ff;font-size:12px}.rv-intro{display:grid;grid-template-columns:.9fr 1.1fr;gap:54px;align-items:center}.rv-visual{background:linear-gradient(145deg,#eef3ff,#fff);border:1px solid var(--rv-line);border-radius:18px;padding:36px;min-height:360px;display:grid;place-items:center;position:relative}.rv-visual img{width:100%;max-height:300px;object-fit:contain}.rv-badge{position:absolute;left:18px;bottom:18px;background:var(--rv-navy);color:#fff;border-radius:9px;padding:12px 15px;font-size:12px}.rv-specgrid{display:grid;grid-template-columns:repeat(2,1fr);gap:0 26px}.rv-spec{padding:16px 0;border-bottom:1px solid var(--rv-line)}.rv-spec b{display:block;color:var(--rv-blue)}.rv-dark{background:linear-gradient(135deg,var(--rv-navy),var(--rv-navy2));color:#fff}.rv-dark .rv-h2{color:#fff}.rv-dark .rv-lead{color:#c8d5ef}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:18px;margin-top:38px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 10px 34px rgba(11,23,49,.07);position:relative;overflow:hidden}.rv-card:before{content:\"\";position:absolute;inset:0 0 auto;height:4px;background:linear-gradient(90deg,var(--rv-blue),#4c7cf5)}.rv-card h3{font-size:19px;line-height:1.3;margin:6px 0 10px}.rv-card p{font-size:14px;color:#5d6a81;margin:0}.rv-num{font-size:12px;color:var(--rv-blue);font-weight:800}.rv-dark .rv-card{background:rgba(255,255,255,.05);border-color:rgba(255,255,255,.14);box-shadow:none}.rv-dark .rv-card h3{color:#fff}.rv-dark .rv-card p{color:#c7d3eb}.rv-flow{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin-top:34px}.rv-step{border:1px solid var(--rv-line);border-radius:10px;padding:20px}.rv-step b{display:block;color:var(--rv-blue);margin-bottom:6px}.rv-step span{font-size:14px;color:#5d6a81}.rv-tablewrap{overflow:auto;border:1px solid var(--rv-line);border-radius:12px;margin-top:34px}.rv-table{width:100%;min-width:760px;border-collapse:collapse}.rv-table th{background:#edf2ff;text-align:left;padding:15px}.rv-table td{padding:15px;border-top:1px solid var(--rv-line);vertical-align:top}.rv-table td:first-child{font-weight:800;color:var(--rv-blue)}.rv-check{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin-top:34px}.rv-check div{border:1px solid rgba(255,255,255,.16);border-radius:10px;padding:16px 18px;color:#dce6f8}.rv-check div:before{content:\"\u2713\";display:inline-grid;place-items:center;width:22px;height:22px;border-radius:50%;background:var(--rv-yellow);color:#111;font-weight:900;margin-right:10px}.rv-faq{border-top:1px solid var(--rv-line);margin-top:30px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:20px 0}.rv-faq summary{cursor:pointer;font-weight:800;list-style:none}.rv-faq summary:after{content:\"+\";float:right;color:var(--rv-blue);font-size:22px}.rv-faq details[open] summary:after{content:\"\u2212\"}.rv-faq p{color:#5b687d;margin:12px 0 0}.rv-cta{background:linear-gradient(115deg,#121f40,#0a1530);border-radius:16px;padding:46px;display:flex;justify-content:space-between;gap:30px;align-items:center}.rv-cta h2{color:#fff;margin:0 0 8px;font-size:32px}.rv-cta p{color:#c9d5ec;margin:0;max-width:650px}.rv-note{font-size:12px;color:#7b879a;margin-top:18px}@media(max-width:980px){.rv-intro{grid-template-columns:1fr}.rv-grid,.rv-flow{grid-template-columns:repeat(2,1fr)}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1180px)}.rv-section{padding:58px 0}.rv-hero{padding:82px 0 66px}.rv-grid,.rv-flow,.rv-specgrid,.rv-check{grid-template-columns:1fr}.rv-cta{display:block;padding:30px 22px}.rv-cta .rv-actions{margin-top:22px}}.rv-topicgrid,.rv-routegrid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-topic,.rv-route{padding:22px;border:1px solid var(--rv-line);border-radius:12px;background:#fff}.rv-topic b,.rv-route b{display:block;color:var(--rv-blue);margin-bottom:7px}.rv-topic p,.rv-route p{margin:0;color:#667085;font-size:14px}.rv-limitgrid{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-limit{padding:24px;border-radius:12px;background:#fff;color:#26344d}.rv-limit h3{margin:0 0 10px;color:#1f29bd;font-size:19px}.rv-limit p{margin:0;font-size:14px}.rv-trust{padding:26px;border:1px solid var(--rv-line);border-left:5px solid var(--rv-blue);border-radius:10px;background:#f8faff}.rv-trustgrid{display:grid;grid-template-columns:1fr 1fr;gap:18px 30px}.rv-trust b{display:block;color:var(--rv-ink);margin-bottom:5px}.rv-trust p{margin:0;color:#667085;font-size:14px}.rv-trustlinks{display:flex;flex-wrap:wrap;gap:10px;margin-top:18px}.rv-trustlinks a{color:var(--rv-blue);font-size:13px;font-weight:800}body.page-id-1312 #content,body.page-id-1312 .site-content,body.page-id-1312 #primary,body.page-id-1312 #main,body.page-id-1312 .entry-content{margin-top:0!important;padding-top:0!important}body.page-id-1312 .site-content>.ast-container{max-width:100%!important;padding-left:0!important;padding-right:0!important}@media(max-width:980px){.rv-topicgrid,.rv-routegrid,.rv-limitgrid{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-topicgrid,.rv-routegrid,.rv-limitgrid,.rv-trustgrid{grid-template-columns:1fr}}<\/style><main class=\"rv-cat\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/support\/\">Resources<\/a> \/ Cryogenic Valve Testing and Qualification<\/div><div class=\"rv-kicker\" style=\"color:#f3cc18\">Low-temperature validation with safety and scope limits<\/div><h1 class=\"rv-title\">Cryogenic Valve Testing: Thermal Control, Leakage and Evidence<\/h1><p>Cryogenic valve testing evaluates defined performance after a valve is cooled to a specified low-temperature condition under an approved procedure. It differs from routine ambient pressure testing because thermal contraction, extended-bonnet temperature gradients, seat and packing behavior, frost\/condensation, test-fluid properties and safe venting all influence the result. The project must define temperature, cooling method, pressure and leakage measurement, cycling, stabilization, acceptance and the relationship between the test article and supplied valves.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Technical Review<\/a><a class=\"rv-btn rv-ghost\" href=\"#technical-scope\">Open Technical Scope<\/a><\/div><div class=\"rv-pills\"><span class=\"rv-pill\">Controlled cooldown<\/span><span class=\"rv-pill\">Temperature mapping<\/span><span class=\"rv-pill\">Leakage measurement<\/span><span class=\"rv-pill\">Design coverage<\/span><\/div><\/div><\/section>\n<section id=\"technical-scope\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Technical scope<\/div><h2 class=\"rv-h2\">Define the cryogenic condition the valve must survive<\/h2><div class=\"rv-topicgrid\"><div class=\"rv-topic\"><b>Minimum design temperature<\/b><p>Start from the actual fluid and upset cases; do not select a test temperature from the word cryogenic alone.<\/p><\/div><div class=\"rv-topic\"><b>Valve configuration<\/b><p>Body pattern, size, class, materials, seat, packing, stem extension, operator and flow direction affect behavior.<\/p><\/div><div class=\"rv-topic\"><b>Cooling and stabilization<\/b><p>Specify cooling medium, immersion\/exposure level, monitored points and stability criteria before measurement.<\/p><\/div><div class=\"rv-topic\"><b>Test fluid and pressure<\/b><p>Define compatible, dry and clean test gas\/liquid, pressure basis, direction and safe relief\/vent arrangement.<\/p><\/div><div class=\"rv-topic\"><b>Leakage method<\/b><p>State internal and external measurement equipment, units, sensitivity, duration and corrections required by the procedure.<\/p><\/div><div class=\"rv-topic\"><b>Thermal cycling and operation<\/b><p>Define valve operations, warm-up, repeat cycles, torque monitoring and post-test ambient examinations.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Evidence matrix<\/div><h2 class=\"rv-h2\">Control the variables that dominate a cryogenic result<\/h2><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Control area<\/th><th>Procedure requirement<\/th><th>Evidence<\/th><th>Failure risk<\/th><\/tr><\/thead><tbody><tr><td>Temperature condition<\/td><td>Target temperature, sensor locations, cooling rate and stabilization band\/time.<\/td><td>Calibrated sensor IDs and continuous temperature chart linked to test steps.<\/td><td>Bulk bath temperature may not prove the pressure boundary and seats reached the required condition.<\/td><\/tr><tr><td>Test article setup<\/td><td>Orientation, insulation, immersion\/exposure level, bonnet extension and operator protection.<\/td><td>Configuration drawing and photographs before\/during test.<\/td><td>An unrepresentative setup can overcool packing or leave critical zones too warm.<\/td><\/tr><tr><td>Pressure and test medium<\/td><td>Compatible medium, cleanliness\/dryness, pressure steps, direction and relief\/venting.<\/td><td>Medium certificate\/identity, pressure chart and instrument calibration.<\/td><td>Moisture can freeze; trapped pressure and rapid vaporization create serious hazards.<\/td><\/tr><tr><td>Seat leakage<\/td><td>Seat direction, closure method, stabilization, measurement device, units and acceptance.<\/td><td>Raw flow\/volume data, time, temperature and pressure at measurement.<\/td><td>Uncorrected or unstable gas measurements can be misleading.<\/td><\/tr><tr><td>External leakage<\/td><td>Body-joint, packing and pressure-boundary observation or instrumented measurement.<\/td><td>Location-specific results and detection method\/sensitivity.<\/td><td>Frost or condensation can obscure the source and should not be mistaken for process leakage.<\/td><\/tr><tr><td>Operation and recovery<\/td><td>Required strokes at temperature, torque\/thrust, warm-up method and ambient retest\/inspection.<\/td><td>Stroke records, actuator settings, post-test examination and final ambient results.<\/td><td>A valve may pass static leakage yet bind, overload the actuator or change after thermal recovery.<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering evidence<\/div><h2 class=\"rv-h2\">Design features to review before cryogenic qualification<\/h2><div class=\"rv-routegrid\"><div class=\"rv-route\"><b>Materials<\/b><p>Pressure-boundary, trim, bolting and weld toughness routes must suit minimum temperature.<\/p><\/div><div class=\"rv-route\"><b>Extended bonnet<\/b><p>Packing temperature, stem conduction, orientation and insulation assumptions need design review.<\/p><\/div><div class=\"rv-route\"><b>Seat system<\/b><p>Differential contraction, cavity relief, sealing direction and pressure locking must be addressed.<\/p><\/div><div class=\"rv-route\"><b>Packing and joints<\/b><p>Low-temperature compatibility, gland loading and gasket behavior influence external containment.<\/p><\/div><div class=\"rv-route\"><b>Actuation<\/b><p>Cold torque\/thrust, stem extension, coupling and position indication affect operation.<\/p><\/div><div class=\"rv-route\"><b>Cleanliness<\/b><p>Moisture, oils and debris can freeze or create incompatibility and measurement problems.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Technical boundaries<\/div><h2 class=\"rv-h2\">Claims and shortcuts this page does not support<\/h2><div class=\"rv-limitgrid\"><div class=\"rv-limit\"><h3>Cryogenic-tested does not mean suitable for every cryogenic fluid<\/h3><p>Material compatibility, cleanliness, oxygen-related hazards, pressure and actual minimum temperature remain service-specific.<\/p><\/div><div class=\"rv-limit\"><h3>One type test does not cover all configurations<\/h3><p>Size, class, seats, packing, materials, stem extension and body pattern require an approved coverage rationale.<\/p><\/div><div class=\"rv-limit\"><h3>Ambient leakage results cannot replace cold results<\/h3><p>Thermal contraction and test-gas behavior create conditions that routine room-temperature tests do not reproduce.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Controlled workflow<\/div><h2 class=\"rv-h2\">From requirement to auditable evidence<\/h2><div class=\"rv-flow\"><div class=\"rv-step\"><b>1. Define the service envelope<\/b><span>Identify fluid, minimum\/maximum conditions, cycles, orientation and containment needs.<\/span><\/div><div class=\"rv-step\"><b>2. Select the qualification route<\/b><span>State applicable standard\/procedure, test article and coverage objective.<\/span><\/div><div class=\"rv-step\"><b>3. Approve safe test setup<\/b><span>Review cooling, sensors, pressure system, ventilation, relief, PPE and emergency controls.<\/span><\/div><div class=\"rv-step\"><b>4. Establish baseline<\/b><span>Complete required ambient tests, identification and instrument checks.<\/span><\/div><div class=\"rv-step\"><b>5. Cool, stabilize and test<\/b><span>Record temperature, pressure, leakage, operation and every deviation continuously.<\/span><\/div><div class=\"rv-step\"><b>6. Warm, inspect and conclude<\/b><span>Control warm-up, repeat ambient checks, examine the valve and issue a bounded report.<\/span><\/div><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\" style=\"color:#f3cc18\">Project checklist<\/div><h2 class=\"rv-h2\">Information and records to define<\/h2><div class=\"rv-check\"><div>Cryogenic fluid and minimum\/maximum design temperatures<\/div><div>Valve type, size, class, materials and complete seal system<\/div><div>Applicable test standard\/procedure and contract edition<\/div><div>Cooling medium, rate, exposure level and sensor map<\/div><div>Pressure\/test gas, direction, cleanliness and relief\/vent system<\/div><div>Leakage method, units, sensitivity, stability and acceptance<\/div><div>Cold operations, torque\/thrust and thermal cycles<\/div><div>Post-test inspection, ambient retest and qualification coverage<\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Technical authority and scope<\/div><h2 class=\"rv-h2\">How this resource should be used<\/h2><div class=\"rv-trust\"><div class=\"rv-trustgrid\"><div><b>Primary search intent<\/b><p>Technical and procurement guidance for defining cryogenic valve qualification or production tests, reviewing cold leakage evidence and preventing overbroad service claims.<\/p><\/div><div><b>Technical content owner<\/b><p>Raymon Valve technical content team. Final project decisions require the controlled documents and responsible engineer or quality reviewer.<\/p><\/div><div><b>Standards boundary<\/b><p>The controlled project specification and applicable cryogenic valve\/test standard define temperatures, pressures, leakage limits and qualification coverage. Testing involves hazardous stored energy and extremely cold media and must be conducted by competent facilities under approved safety procedures.<\/p><\/div><div><b>Review status<\/b><p>Technical scope reviewed 27 July 2026. Editions, procedures, acceptance criteria and product evidence must be reconfirmed before order.<\/p><\/div><\/div><div class=\"rv-trustlinks\"><a href=\"\/support\/\">Resource Center<\/a><a href=\"\/valve-standards\/\">Valve Standards<\/a><a href=\"\/valve-inspection\/\">Inspection &amp; Testing<\/a><a href=\"\/contact\/\">Request Technical Review<\/a><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Frequently asked questions<\/div><h2 class=\"rv-h2\">Cryogenic Valve Testing and Qualification FAQ<\/h2><div class=\"rv-faq\"><details><summary>What temperature is used for cryogenic valve testing?<\/summary><p>It depends on the project fluid, minimum design temperature and governing procedure. The target, sensor locations and stabilization criteria must be stated; there is no single temperature for every cryogenic service.<\/p><\/details><details><summary>Why do cryogenic valves use extended bonnets?<\/summary><p>An extension can help maintain the packing and operator region at a more manageable temperature, subject to valve orientation, insulation, conduction, process conditions and design details.<\/p><\/details><details><summary>Is cryogenic testing performed with liquid nitrogen inside the valve?<\/summary><p>Test arrangements vary. A valve may be externally cooled while a controlled test gas is used for pressure\/leakage measurement. The approved standard\/procedure and safety assessment determine the setup.<\/p><\/details><details><summary>What should a cryogenic test report include?<\/summary><p>Include valve configuration, procedure, setup, cooling medium, sensor map and temperature chart, pressure\/test medium, leakage data, cold operations, instrument IDs, deviations, recovery inspection and qualification scope.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section\" style=\"padding-top:0\"><div class=\"rv-wrap\"><div class=\"rv-cta\"><div><div class=\"rv-kicker\" style=\"color:#f3cc18\">Technical evidence review<\/div><h2>Send the requirement and the evidence you need to verify<\/h2><p>We will identify the applicable scope, missing records and approval path without inventing compliance claims.<\/p><\/div><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Technical Review<\/a><\/div><\/div><\/div><\/section>\n<\/main><script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Resources\",\"item\":\"https:\/\/raymonvalve.com\/support\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Cryogenic Valve Testing and Qualification\",\"item\":\"https:\/\/raymonvalve.com\/valve-cryogenic-testing\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What temperature is used for cryogenic valve testing?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It depends on the project fluid, minimum design temperature and governing procedure. The target, sensor locations and stabilization criteria must be stated; there is no single temperature for every cryogenic service.\"}},{\"@type\":\"Question\",\"name\":\"Why do cryogenic valves use extended bonnets?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An extension can help maintain the packing and operator region at a more manageable temperature, subject to valve orientation, insulation, conduction, process conditions and design details.\"}},{\"@type\":\"Question\",\"name\":\"Is cryogenic testing performed with liquid nitrogen inside the valve?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Test arrangements vary. A valve may be externally cooled while a controlled test gas is used for pressure\/leakage measurement. The approved standard\/procedure and safety assessment determine the setup.\"}},{\"@type\":\"Question\",\"name\":\"What should a cryogenic test report include?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Include valve configuration, procedure, setup, cooling medium, sensor map and temperature chart, pressure\/test medium, leakage data, cold operations, instrument IDs, deviations, recovery inspection and qualification scope.\"}}]}]<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Cryogenic valve testing evaluates defined performance after a valve is cooled to a specified low-temperature condition under an approved procedure.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1312","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/1312","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/comments?post=1312"}],"version-history":[{"count":49,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/1312\/revisions"}],"predecessor-version":[{"id":13496,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/1312\/revisions\/13496"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/media?parent=1312"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}