{"id":13721,"date":"2026-07-27T22:09:51","date_gmt":"2026-07-27T14:09:51","guid":{"rendered":"https:\/\/raymonvalve.com\/documentation-package\/"},"modified":"2026-07-27T22:45:45","modified_gmt":"2026-07-27T14:45:45","slug":"documentation-package","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/fr\/documentation-package\/","title":{"rendered":"Dossier de documentation"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13721\" class=\"elementor elementor-13721 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b0b7a106 e-con-full e-flex e-con e-parent\" data-id=\"b0b7a106\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1bf8f03 elementor-widget elementor-widget-html\" data-id=\"a1bf8f03\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valve-solutions\/\">Solutions<\/a> \/ Documentation Package<\/div><div class=\"rv-kicker\">Engineering solution<\/div><h1>Documentation Package: Engineering Review Framework<\/h1><p>Documentation Package requires a defined engineering problem, measurable acceptance criteria and traceable evidence. This page explains how Raymon Valve structures requirements and evidence control, what project data controls the decision and which risks should be closed before manufacture or package release.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Set the technical boundary before comparing valves<\/h2><p class=\"rv-lead\">The search intent behind documentation package is practical: convert a process or procurement problem into an approved valve requirement and evidence plan. For engineers and buyers who need a defensible solution route rather than a generic product recommendation, the goal is a defensible decision trail rather than an unsupported product claim.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Define the functional objective<\/b><p>Treat this as an engineering decision with controlled inputs, stated assumptions, approved limits and a traceable closeout record.<\/p><\/div><div class=\"rv-card\"><b>02. Freeze boundary conditions<\/b><p>Document the duty cases, physical interfaces, decision limits and the record that will demonstrate acceptance before technical release.<\/p><\/div><div class=\"rv-card\"><b>03. Compare feasible construction routes<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>04. Verify package performance and records<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Service, jurisdiction, project specification and construction can change the result; verify current standards, calculations and supplier documents.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Freeze the decisions that control technical approval<\/h2><p class=\"rv-lead\">A clear evidence route exposes scope gaps early and prevents a generic quotation from being mistaken for technical compliance.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Define why the documentation package tag exists, what failure looks like and which state protects the process.<\/td><td>P&ID, process narrative, tag criticality and approved shutdown philosophy<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Quantify document hierarchy and approved editions and include every case that can control sizing, material or sealing.<\/td><td>Approved process cases, fluid-property source and assumptions register<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Freeze nominal size, rating route, bore, end details, orientation, loads, access and removable envelope.<\/td><td>Line class, piping arrangement, mating-interface schedule and approved general arrangement<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Map each wetted, load-bearing and sealing component to its environment, fabrication route and verification method.<\/td><td>Materials-selection record, drawing\/BOM, heat traceability and inspection results<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Use worst-case valve load and minimum utility to engineer the operator, controls, indication and safe response.<\/td><td>Torque\/thrust basis, actuator sizing, accessories list and package test procedure<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Define the supplier evidence needed to confirm material identity, manufacture, assembly and functional performance.<\/td><td>Controlled procedures, certificates, test reports, NCR closeout and turnover dossier<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Where incomplete requirements become valve failures<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Copying conflicting clauses<\/b><p>Tie mitigation to the actual operating case and verify it through calculation, qualification, inspection or package-level testing.<\/p><\/div><div class=\"rv-card\"><b>Accepting generic certificates<\/b><p>Record the residual risk after design review and make the relevant drawing, procedure or test result part of the tag dossier.<\/p><\/div><div class=\"rv-card\"><b>Losing traceability between tag, heat and test report<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">A controlled path from service data to turnover records<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for documentation package that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially document hierarchy and approved editions.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Complete the hydraulic, torque\/thrust, rating, corrosion or transient checks that govern this duty.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Cross-check the supplier proposal with the datasheet, line class, project standards and risk register.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Confirm manufacturing and documentation closeout so the delivered valve can be identified, installed and maintained correctly.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Data needed before price and delivery can be compared fairly<\/h2><p class=\"rv-lead\">Treat missing data as an open point. Silent assumptions can change materials, dimensions, actuator size, test scope, cost and lead time.<\/p><ul class=\"rv-check\"><li>Review purpose and decision owner confirmed for Documentation Package<\/li><li>Tag, system function and consequence of failure<\/li><li>Document hierarchy and approved editions<\/li><li>Tag-level datasheet inputs<\/li><li>Minimum\/normal\/maximum process cases and all design transients<\/li><li>Fluid composition, phase, solids, contaminants and cleaning media<\/li><li>Mechanical interfaces, allowable loads, operator position and maintenance space<\/li><li>Component-level materials map including welds, overlay, packing, gaskets and fasteners<\/li><li>Operator load, cycle frequency, speed, safe position, power\/air and control interfaces<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>Pressure, leakage, functional, NDE and special test acceptance criteria<\/li><li>Required submittals, approval schedule, final records, preservation and commercial boundaries<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Marketing content can explain a route, but only controlled drawings, calculations, certificates, procedures and results can close an order requirement.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Connect this decision with valve families and quality controls<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valve-solutions\/\">Solutions<small>Return to the solutions hub.<\/small><\/a><a class=\"rv-link\" href=\"\/pipeline-valve-solutions\/\">Pipeline Valve Solutions<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/actuator-torque-review\/\">Actuator Torque Review<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/steam-valves\/\">Steam Service Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Documentation Package<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Documentation Package?<\/summary><p>Provide document hierarchy and approved editions, tag-level datasheet inputs, inspection and test records, final turnover index and traceability together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Documentation Package?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Use a controlled standards register with titles, editions and responsibility. Separate product, rating, dimensions, tests, materials and special qualification instead of citing one document for everything.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Give engineering enough information to challenge assumptions<\/h2><p>Share fluid details, pressure-temperature and flow cases, piping interfaces, operation, standards, tests and documents. Raymon Valve can return a clarified route and open-point list.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions\",\"item\":\"https:\/\/raymonvalve.com\/valve-solutions\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Documentation Package\",\"item\":\"https:\/\/raymonvalve.com\/documentation-package\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Documentation Package?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide document hierarchy and approved editions, tag-level datasheet inputs, inspection and test records, final turnover index and traceability together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Documentation Package?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use a controlled standards register with titles, editions and responsibility. Separate product, rating, dimensions, tests, materials and special qualification instead of citing one document for everything.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Examiner le package de documentation : donn\u00e9es de service, construction, mat\u00e9riaux, fonctionnement, tests et entr\u00e9es RFQ pour la s\u00e9lection de vannes sp\u00e9cifiques au projet.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13721","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/13721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/comments?post=13721"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/13721\/revisions"}],"predecessor-version":[{"id":13980,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/pages\/13721\/revisions\/13980"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/media?parent=13721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}