{"id":14618,"date":"2026-09-16T11:34:00","date_gmt":"2026-09-16T03:34:00","guid":{"rendered":"https:\/\/raymonvalve.com\/?p=14618"},"modified":"2026-09-17T14:12:22","modified_gmt":"2026-09-17T06:12:22","slug":"gate-valve-pressure-locking-vs-thermal-binding","status":"publish","type":"post","link":"https:\/\/raymonvalve.com\/fr\/blog\/gate-valve-pressure-locking-vs-thermal-binding\/","title":{"rendered":"Gate Valve Pressure Locking vs Thermal Binding: Causes, Operating Symptoms, Prevention and Design Review"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"14618\" class=\"elementor elementor-14618\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11b3bacd e-flex e-con-boxed e-con e-parent\" data-id=\"11b3bacd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-387623c6 elementor-widget elementor-widget-text-editor\" data-id=\"387623c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"text-align: left;\"><style>\n.raymonvalve-blog-page {\n    max-width: 1120px;\n    margin: 0 auto;\n    padding: 24px;\n    font-family: Arial, Helvetica, sans-serif;\n    color: #222;\n    line-height: 1.75;\n}\n\n.raymonvalve-blog-page h1 {\n    font-size: 42px;\n    line-height: 1.25;\n    margin-bottom: 24px;\n}\n\n.raymonvalve-blog-page h2 {\n    margin-top: 48px;\n    margin-bottom: 20px;\n    line-height: 1.35;\n}\n\n.raymonvalve-blog-page h3 {\n    margin-top: 32px;\n    margin-bottom: 14px;\n}\n\n.raymonvalve-blog-page p {\n    margin-bottom: 18px;\n}\n\n.raymonvalve-blog-page img {\n    max-width: 100%;\n    height: auto;\n    display: block;\n    margin: 32px auto;\n}\n\n.raymonvalve-table-wrap {\n    overflow-x: auto;\n    margin: 28px 0;\n}\n\n.raymonvalve-blog-page table {\n    width: 100%;\n    min-width: 720px;\n    border-collapse: collapse;\n}\n\n.raymonvalve-blog-page th,\n.raymonvalve-blog-page td {\n    border: 1px solid #ddd;\n    padding: 12px;\n    vertical-align: top;\n}\n\n.raymonvalve-blog-page ul {\n    padding-left: 24px;\n}\n\n.raymonvalve-note {\n    padding: 20px;\n    margin: 30px 0;\n    border-left: 4px solid #555;\n}\n\n.raymonvalve-cta {\n    margin-top: 50px;\n    padding: 28px;\n    border-left: 4px solid #1c5d8f;\n}\n\n.raymonvalve-cta a {\n    display: inline-block;\n    margin-top: 18px;\n    padding: 12px 24px;\n    text-decoration: none;\n}\n\n@media(max-width:768px){\n\n.raymonvalve-blog-page {\n    padding: 16px;\n}\n\n.raymonvalve-blog-page h1 {\n    font-size: 32px;\n}\n\n.raymonvalve-table-wrap {\n    width:100%;\n}\n\n.raymonvalve-cta a {\n    width:100%;\n    text-align:center;\n}\n\n}\n<\/style><\/p>\n<article class=\"raymonvalve-blog-page\">\n<h1>Gate Valve Pressure Locking vs Thermal Binding: Causes, Operating Symptoms, Prevention and Design Review<\/h1>\n<p>Gate valve pressure locking and thermal binding are two different mechanisms that may increase valve operating resistance under certain service conditions. Pressure locking is generally related to trapped pressure conditions that increase the force required for movement, while thermal binding is associated with temperature-driven expansion effects that may influence mechanical interaction between valve components.<\/p>\n<p>For engineers, procurement teams, and maintenance personnel, identifying the difference is important because similar operating symptoms may require different investigation paths. Reviewing valve construction, pressure-temperature conditions, installation arrangement, operating sequence, and available technical data helps determine what information should be checked before corrective action or supplier discussion.<\/p>\n<div class=\"raymonvalve-note\"><strong>Engineering Note:<\/strong>\n<p>Increased gate valve operating resistance does not automatically confirm pressure locking or thermal binding. Other factors, including mechanical damage, contamination, installation conditions, or service-related changes, may create similar symptoms. Actual evaluation should be based on project-specific valve data and operating conditions.<\/p>\n<\/div>\n<h2>Pressure Locking vs Thermal Binding: Quick Engineering Difference<\/h2>\n<div class=\"raymonvalve-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Review Item<\/th>\n<th>Pressure Locking<\/th>\n<th>Thermal Binding<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Primary mechanism<\/td>\n<td>Trapped pressure conditions affecting the force required for valve movement<\/td>\n<td>Temperature-related expansion or contraction effects influencing mechanical interaction<\/td>\n<\/tr>\n<tr>\n<td>Typical trigger<\/td>\n<td>Pressure changes, isolation conditions, or trapped fluid scenarios<\/td>\n<td>Heating, cooling, or temperature cycling during service<\/td>\n<\/tr>\n<tr>\n<td>Main review focus<\/td>\n<td>Pressure scenario, valve arrangement, and operating sequence<\/td>\n<td>Temperature history, materials, and component movement conditions<\/td>\n<\/tr>\n<tr>\n<td>Useful review data<\/td>\n<td>Pressure conditions, valve construction, system operation sequence<\/td>\n<td>Temperature range, thermal cycle, installation and mechanical conditions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>What Is Gate Valve Pressure Locking?<\/h2>\n<p>Pressure locking refers to a condition where pressure becomes trapped within a valve cavity or pressure-containing area and creates additional resistance during operation. The resulting increase in required operating force depends on the valve design, pressure conditions, installation arrangement, and operating sequence.<\/p>\n<p>The issue should be reviewed as an operating scenario rather than as an automatic defect of a specific valve type. A complete assessment requires understanding how pressure conditions develop during normal operation, shutdown, isolation, or process changes.<\/p>\n<img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-pressure-locking-mechanism-diagram.webp\" alt=\"Gate valve pressure locking mechanism concept diagram showing trapped pressure effect on operating force\" width=\"1200\" height=\"900\" title=\"\">Engineering schematic showing the concept of trapped pressure conditions and their potential influence on gate valve operating resistance.\n<h3>How Pressure Locking Develops During Operation<\/h3>\n<p>Pressure locking evaluation normally requires reviewing the relationship between valve construction and the surrounding piping system. Important considerations may include:<\/p>\n<ul>\n<li>Pressure conditions before and after isolation;<\/li>\n<li>Possible trapped fluid areas within the valve arrangement;<\/li>\n<li>Operating sequence during startup, shutdown, or maintenance activities;<\/li>\n<li>Valve design details that influence internal pressure behavior.<\/li>\n<\/ul>\n<p>Because operating conditions vary between applications, pressure locking assessment should be based on actual service information rather than a general assumption.<\/p>\n<h2>Typical Operating Symptoms of Pressure Locking<\/h2>\n<p>Pressure locking may be considered when a valve shows different operating behavior under different pressure conditions. However, these symptoms should be verified against other possible mechanical or service-related causes.<\/p>\n<div class=\"raymonvalve-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Observed Symptom<\/th>\n<th>Possible Review Direction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Valve becomes difficult to open after isolation<\/td>\n<td>Review whether pressure conditions may have changed within the valve arrangement<\/td>\n<\/tr>\n<tr>\n<td>Higher operating force appears under specific conditions<\/td>\n<td>Review valve data, operating sequence, and service scenario<\/td>\n<\/tr>\n<tr>\n<td>Valve behavior changes between operating cycles<\/td>\n<td>Compare pressure conditions and system operation history<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>What Is Thermal Binding in Gate Valves?<\/h2>\n<p>Thermal binding is associated with temperature-related expansion and contraction effects that may influence the interaction between valve components. The actual effect depends on valve design, materials, temperature conditions, and installation environment.<\/p>\n<p>Temperature rating alone does not explain all operating behavior. Engineers should consider the complete temperature cycle, including heating, cooling, startup, shutdown, and process changes that may affect component movement.<\/p>\n<img decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-thermal-binding-mechanism-diagram.webp\" alt=\"Gate valve thermal binding concept diagram showing temperature-related expansion effects\" width=\"1200\" height=\"900\" title=\"\">Engineering schematic illustrating how temperature-related expansion effects may influence gate valve mechanical movement.\n<h3>Temperature-Related Review Considerations<\/h3>\n<ul>\n<li>Operating temperature range and temperature cycling history;<\/li>\n<li>Material behavior under the intended service conditions;<\/li>\n<li>Mechanical interaction between valve components;<\/li>\n<li>Installation conditions that may influence valve movement.<\/li>\n<\/ul>\n<!-- Part 2 continues --><\/article>\n<h2>Pressure Locking vs Thermal Binding: Detailed Engineering Comparison<\/h2>\n<p>Although pressure locking and thermal binding may create similar operating symptoms, the engineering causes behind them are different. Understanding the difference helps engineers define the correct review direction during troubleshooting, specification preparation, and supplier technical discussions.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-pressure-locking-vs-thermal-binding-comparison.webp\" alt=\"Gate valve pressure locking versus thermal binding comparison matrix\" width=\"1200\" height=\"900\" title=\"\">Comparison matrix showing the different engineering considerations for pressure locking and thermal binding evaluation.<\/p>\n<div class=\"raymonvalve-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Engineering Review Item<\/th>\n<th>Pressure Locking<\/th>\n<th>Thermal Binding<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Main cause<\/td>\n<td>Pressure trapped within a valve cavity or related pressure area that increases movement resistance<\/td>\n<td>Temperature-related expansion or contraction effects that influence component interaction<\/td>\n<\/tr>\n<tr>\n<td>Typical operating condition<\/td>\n<td>Pressure isolation, pressure changes, or specific system operating sequences<\/td>\n<td>Heating, cooling, startup, shutdown, or temperature cycling conditions<\/td>\n<\/tr>\n<tr>\n<td>Primary investigation path<\/td>\n<td>Review pressure conditions, valve arrangement, and operating sequence<\/td>\n<td>Review temperature history, materials, and mechanical movement conditions<\/td>\n<\/tr>\n<tr>\n<td>Key engineering inputs<\/td>\n<td>Pressure scenario, valve construction, system conditions<\/td>\n<td>Temperature range, thermal cycle, installation conditions<\/td>\n<\/tr>\n<tr>\n<td>Potential mitigation review<\/td>\n<td>Evaluate valve design and operating scenario based on application requirements<\/td>\n<td>Evaluate design suitability considering temperature effects and service conditions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>How Engineers Identify the Root Cause<\/h2>\n<p>When a gate valve becomes difficult to operate, engineers should avoid assuming a single cause. Similar symptoms may result from different mechanisms, so a structured review should compare operating history, valve information, and service conditions.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-operating-failure-troubleshooting-flowchart.webp\" alt=\"Gate valve operating failure troubleshooting flowchart for pressure locking and thermal binding review\" width=\"1200\" height=\"900\" title=\"\">Troubleshooting flowchart providing a structured review path for gate valve operating resistance.<\/p>\n<h3>Gate Valve Operating Resistance Review Matrix<\/h3>\n<div class=\"raymonvalve-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Observed Symptom<\/th>\n<th>Possible Mechanism<\/th>\n<th>Information to Review<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Valve becomes difficult to open after isolation<\/td>\n<td>Possible pressure-related operating condition<\/td>\n<td>Pressure scenario, isolation arrangement, operating sequence<\/td>\n<\/tr>\n<tr>\n<td>Valve becomes difficult to operate after temperature cycling<\/td>\n<td>Possible thermal-related effect<\/td>\n<td>Temperature history, materials, component movement conditions<\/td>\n<\/tr>\n<tr>\n<td>Higher actuator demand than expected<\/td>\n<td>Increased operating resistance<\/td>\n<td>Valve operating data, service condition, actuator information<\/td>\n<\/tr>\n<tr>\n<td>Operating problem appears intermittently<\/td>\n<td>Changing process or operating condition<\/td>\n<td>Startup\/shutdown sequence, process changes, maintenance history<\/td>\n<\/tr>\n<tr>\n<td>Cause cannot be identified from pressure or temperature review<\/td>\n<td>Other mechanical or service-related factors<\/td>\n<td>Inspection records, internal condition, installation review<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Prevention and Gate Valve Design Review Considerations<\/h2>\n<p>The most effective approach is to review possible operating challenges during specification and design review rather than relying only on corrective action after operation problems occur.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-operating-condition-review-diagram.webp\" alt=\"Gate valve operating condition review diagram showing pressure temperature and installation factors\" width=\"1200\" height=\"900\" title=\"\">Engineering relationship diagram showing the service factors commonly reviewed during gate valve evaluation.<\/p>\n<h3>Key Design Review Items<\/h3>\n<ul>\n<li>Valve construction and configuration;<\/li>\n<li>Pressure and temperature operating conditions;<\/li>\n<li>Medium characteristics and service environment;<\/li>\n<li>Installation arrangement within the piping system;<\/li>\n<li>Operating sequence during startup, shutdown, and isolation;<\/li>\n<li>Actuation requirements based on confirmed valve data;<\/li>\n<li>Testing and documentation requirements.<\/li>\n<\/ul>\n<h2>Gate Valve RFQ and Design Review Checklist<\/h2>\n<p>Providing complete application information allows suppliers to review valve suitability more effectively. The following information is commonly useful during RFQ preparation and technical evaluation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-rfq-design-review-checklist.webp\" alt=\"Gate valve RFQ design review checklist showing required engineering information\" width=\"1200\" height=\"900\" title=\"\">Checklist of engineering information commonly reviewed during gate valve specification and supplier discussions.<\/p>\n<div class=\"raymonvalve-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Required Information<\/th>\n<th>Purpose<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Valve type and construction<\/td>\n<td>Understand valve design characteristics and application requirements<\/td>\n<\/tr>\n<tr>\n<td>Size and pressure class<\/td>\n<td>Define the intended pressure service condition<\/td>\n<\/tr>\n<tr>\n<td>Medium and service conditions<\/td>\n<td>Support material and application review<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range<\/td>\n<td>Evaluate temperature-related operating considerations<\/td>\n<\/tr>\n<tr>\n<td>Installation arrangement<\/td>\n<td>Understand system influence on operation<\/td>\n<\/tr>\n<tr>\n<td>Operating sequence<\/td>\n<td>Review possible pressure or temperature scenarios<\/td>\n<\/tr>\n<tr>\n<td>Actuation method<\/td>\n<td>Support operating capability review<\/td>\n<\/tr>\n<tr>\n<td>Testing and documentation requirements<\/td>\n<td>Define supplier technical deliverables<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Questions to Ask During Supplier Design Review<\/h2>\n<ul>\n<li>Has the valve operating scenario been reviewed based on actual service conditions?<\/li>\n<li>Are pressure and temperature conditions clearly defined?<\/li>\n<li>Has the installation arrangement been considered during evaluation?<\/li>\n<li>Are actuator requirements based on confirmed valve operating information?<\/li>\n<li>Are testing and documentation requirements clearly specified?<\/li>\n<\/ul>\n<h2>Engineering References<\/h2>\n<p>Pressure locking and thermal binding have been discussed as engineering considerations in certain gate valve operating scenarios. Industry operating experience documents, including NRC Generic Letter 95-07, highlight the importance of reviewing valve design, operating conditions, and functional requirements when evaluating these mechanisms.<\/p>\n<p>Reference documents should be applied according to the relevant project requirements and service conditions. This article provides general engineering guidance and does not replace project-specific valve analysis or manufacturer technical evaluation.<\/p>\n<h2>Conclusion<\/h2>\n<p>Gate valve pressure locking and thermal binding may produce similar operating symptoms, but they represent different engineering mechanisms. Pressure locking is mainly associated with pressure-related conditions, while thermal binding is related to temperature-driven effects that may influence valve component interaction.<\/p>\n<p>A structured review of valve construction, pressure-temperature conditions, installation arrangement, operating sequence, and technical documentation helps engineers identify the appropriate evaluation path. For critical applications, the most reliable approach is to review potential operating challenges during specification and design stages rather than relying only on corrective action after operation issues occur.<\/p>\n<div class=\"raymonvalve-note\"><strong>Engineering Boundary:<\/strong>\n<p>This article provides general engineering guidance for understanding gate valve pressure locking and thermal binding considerations. Actual valve behavior depends on valve design, service conditions, installation arrangement, operating sequence, and project requirements. Final evaluation should be based on complete technical information and responsible engineering review.<\/p>\n<\/div>\n<h2>Frequently Asked Questions<\/h2>\n<h3>What is the difference between pressure locking and thermal binding in gate valves?<\/h3>\n<p>Pressure locking is associated with trapped pressure conditions that may increase the force required for valve operation. Thermal binding is related to temperature-driven expansion and contraction effects that may influence mechanical interaction between valve components. The two conditions require different engineering reviews.<\/p>\n<h3>Why can a gate valve become difficult to open after shutdown?<\/h3>\n<p>A gate valve may become difficult to operate due to different possible factors, including pressure-related conditions, temperature effects, mechanical issues, contamination, installation conditions, or service changes. The actual cause should be identified through review of operating history and valve information.<\/p>\n<h3>Can increasing actuator output solve gate valve operating problems?<\/h3>\n<p>Not necessarily. Increasing actuator capability does not address every source of operating resistance. The valve condition, operating scenario, required operating force, and confirmed technical data should be reviewed before selecting a solution.<\/p>\n<h3>What information should be reviewed before approving a gate valve for critical service?<\/h3>\n<p>Important information may include valve construction, size, pressure-temperature conditions, medium, installation arrangement, operating sequence, actuation requirements, and testing or documentation requirements.<\/p>\n<h3>How can suppliers support gate valve design review?<\/h3>\n<p>Suppliers can support technical evaluation by reviewing valve construction, application conditions, available technical documents, operating requirements, and project-specific specifications.<\/p>\n<div class=\"raymonvalve-cta\">\n<h2>Request Gate Valve Design Review<\/h2>\n<p>Send your valve type, construction, size, pressure class, medium, operating temperature, installation arrangement, operating sequence, actuation method, and required testing scope for a project-specific review.<\/p>\n<a href=\"https:\/\/raymonvalve.com\/contact\/\"> Request a Valve Review <\/a><\/div>\n<!-- Internal Links -->\n<p>For more information about <a href=\"https:\/\/raymonvalve.com\/gate-valves\/\">gate valve solutions<\/a>, review available valve configurations and application information.<\/p>\n<p>For technical documentation and inspection-related considerations, see <a href=\"https:\/\/raymonvalve.com\/valve-pressure-testing\/\">valve testing and inspection requirements<\/a>.<\/p>\n<p>Learn more about <a href=\"https:\/\/raymonvalve.com\/about-us\/\">Raymon Valve supplier information<\/a> and engineering support capabilities.<\/p>\n<!-- Schema -->\n<p><script type=\"application\/ld+json\">\n\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"BlogPosting\",\n\"headline\":\"Gate Valve Pressure Locking vs Thermal Binding: Causes, Operating Symptoms, Prevention and Design Review\",\n\"description\":\"Understand the difference between gate valve pressure locking and thermal binding, including causes, operating symptoms, prevention methods and design review considerations.\",\n\"image\":\"https:\/\/raymonvalve.com\/wp-content\/uploads\/2026\/09\/gate-valve-pressure-locking-vs-thermal-binding-comparison.webp\",\n\"author\":{\n\"@type\":\"Organization\",\n\"name\":\"Raymon Valve Engineering Team\"\n},\n\"publisher\":{\n\"@type\":\"Organization\",\n\"name\":\"Raymon Valve\"\n},\n\"mainEntityOfPage\":{\n\"@type\":\"WebPage\",\n\"@id\":\"https:\/\/raymonvalve.com\/blog\/gate-valve-pressure-locking-vs-thermal-binding\/\"\n}\n}\n\n<\/script> <script type=\"application\/ld+json\">\n\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n\n{\n\"@type\":\"Question\",\n\"name\":\"What is the difference between pressure locking and thermal binding in gate valves?\",\n\"acceptedAnswer\":{\n\"@type\":\"Answer\",\n\"text\":\"Pressure locking is associated with trapped pressure conditions that may increase the force required for valve operation. Thermal binding is related to temperature-driven expansion and contraction effects that may influence mechanical interaction between valve components.\"\n}\n},\n\n{\n\"@type\":\"Question\",\n\"name\":\"Why can a gate valve become difficult to open after shutdown?\",\n\"acceptedAnswer\":{\n\"@type\":\"Answer\",\n\"text\":\"Possible causes include pressure-related conditions, temperature effects, mechanical issues, contamination, installation conditions, or service changes. The actual cause should be identified through review of operating history and valve information.\"\n}\n},\n\n{\n\"@type\":\"Question\",\n\"name\":\"Can increasing actuator output solve gate valve operating problems?\",\n\"acceptedAnswer\":{\n\"@type\":\"Answer\",\n\"text\":\"Increasing actuator capability does not address every source of operating resistance. Valve condition, operating scenario, required operating force, and confirmed technical data should be reviewed before selecting a solution.\"\n}\n},\n\n{\n\"@type\":\"Question\",\n\"name\":\"What information should be reviewed before approving a gate valve for critical service?\",\n\"acceptedAnswer\":{\n\"@type\":\"Answer\",\n\"text\":\"Important information may include valve construction, size, pressure-temperature conditions, medium, installation arrangement, operating sequence, actuation requirements, and testing or documentation requirements.\"\n}\n},\n\n{\n\"@type\":\"Question\",\n\"name\":\"How can suppliers support gate valve design review?\",\n\"acceptedAnswer\":{\n\"@type\":\"Answer\",\n\"text\":\"Suppliers can support technical evaluation by reviewing valve construction, application conditions, available technical documents, operating requirements, and project-specific specifications.\"\n}\n}\n\n]\n}\n\n<\/script><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Gate Valve Pressure Locking vs Thermal Binding: Causes, Operating Symptoms, Prevention and Design Review Gate valve [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-14618","post","type-post","status-publish","format-standard","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/posts\/14618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/comments?post=14618"}],"version-history":[{"count":5,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/posts\/14618\/revisions"}],"predecessor-version":[{"id":14623,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/posts\/14618\/revisions\/14623"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/media?parent=14618"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/categories?post=14618"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/fr\/wp-json\/wp\/v2\/tags?post=14618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}