{"id":13630,"date":"2026-07-27T22:02:58","date_gmt":"2026-07-27T14:02:58","guid":{"rendered":"https:\/\/raymonvalve.com\/hydrogen-chlor-alkali-valves\/"},"modified":"2026-07-27T22:38:52","modified_gmt":"2026-07-27T14:38:52","slug":"hydrogen-chlor-alkali-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/it\/hydrogen-chlor-alkali-valves\/","title":{"rendered":"Valvole per idrogeno e cloro-alcali"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13630\" class=\"elementor elementor-13630 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b4834be7 e-con-full e-flex e-con e-parent\" data-id=\"b4834be7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee4ba28f elementor-widget elementor-widget-html\" data-id=\"ee4ba28f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ Hydrogen & Chlor-Alkali Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>Hydrogen & Chlor-Alkali Valves: Application and Selection Guide<\/h1><p>Hydrogen & Chlor-Alkali Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Turn the search question into controlled project inputs<\/h2><p class=\"rv-lead\">For hydrogen & chlor-alkali valves, the first review should cover complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions. This page is written for application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system; it avoids universal suitability or certification claims that lack order evidence.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Raw-material unloading<\/b><p>Review the system condition and failure consequence, select a defensible route and retain evidence that applies to the actual valve tag.<\/p><\/div><div class=\"rv-card\"><b>02. Reaction and circulation<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>03. Solvent or electrolyte transfer<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>04. Scrubbing and wastewater<\/b><p>Define what success means for this item, then connect the requirement to a drawing, calculation, inspection or functional result.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Service, jurisdiction, project specification and construction can change the result; verify current standards, calculations and supplier documents.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Translate application data into a reviewable valve requirement<\/h2><p class=\"rv-lead\">Review each decision area across disciplines, record deviations and require proof that applies to the proposed configuration.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>State the required action of hydrogen & chlor-alkali valves during normal operation, startup, trip, shutdown and loss of utility.<\/td><td>Controlled tag description, system narrative and cause-and-effect where relevant<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Quantify complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions and include every case that can control sizing, material or sealing.<\/td><td>Approved process cases, fluid-property source and assumptions register<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Check the installed connection, flow direction, support loads, operator envelope and future removal path.<\/td><td>Piping isometric, interface dimensions and marked-up supplier drawing<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>State manual or automated duty, cycle rate, fail state, utility limits, travel time, feedback and interlocks.<\/td><td>Sizing calculation, control narrative, hook-up\/interface drawings and functional test<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Define the supplier evidence needed to confirm material identity, manufacture, assembly and functional performance.<\/td><td>Controlled procedures, certificates, test reports, NCR closeout and turnover dossier<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Risks the proposal must address explicitly<\/h2><p class=\"rv-lead\">These risks should appear in the supplier clarification and inspection plan rather than remain implied in a commercial description.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Chemical incompatibility<\/b><p>Tie mitigation to the actual operating case and verify it through calculation, qualification, inspection or package-level testing.<\/p><\/div><div class=\"rv-card\"><b>Permeation and external leakage<\/b><p>The proposal should explain the design safeguard, identify its limit and point to the order record that verifies it.<\/p><\/div><div class=\"rv-card\"><b>Contamination and cleanability<\/b><p>Tie mitigation to the actual operating case and verify it through calculation, qualification, inspection or package-level testing.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">How to move from open question to approved valve tag<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for hydrogen & chlor-alkali valves that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Create a short list of technical routes and record why alternatives were retained or rejected.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Complete the hydraulic, torque\/thrust, rating, corrosion or transient checks that govern this duty.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Review drawings, calculations, materials, qualification scope and inspection plan against the controlled specification.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Release only the approved configuration and preserve its revision, inspections and final records in the tag dossier.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Data needed before price and delivery can be compared fairly<\/h2><p class=\"rv-lead\">Treat missing data as an open point. Silent assumptions can change materials, dimensions, actuator size, test scope, cost and lead time.<\/p><ul class=\"rv-check\"><li>Application scope frozen: Industry application for Hydrogen & Chlor-Alkali Valves<\/li><li>Tag, system function and consequence of failure<\/li><li>Complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Pressure-temperature cases with differential pressure and duration where relevant<\/li><li>Media constituents, concentration, phase behavior, impurities and cleaning exposure<\/li><li>Mechanical interfaces, allowable loads, operator position and maintenance space<\/li><li>Body, trim, seat, sealing, bolting, coating or lining materials<\/li><li>Operator load, cycle frequency, speed, safe position, power\/air and control interfaces<\/li><li>Applicable standards with exact project-approved editions and purchaser options<\/li><li>Inspection methods, sampling, test configuration, instruments and acceptance limits<\/li><li>Required submittals, approval schedule, final records, preservation and commercial boundaries<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Marketing content can explain a route, but only controlled drawings, calculations, certificates, procedures and results can close an order requirement.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Use the next pages to narrow product and evidence scope<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/hydrogen-valves\/\">Hydrogen Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/lng-cryogenic-valves\/\">LNG & Cryogenic Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/marine-offshore\/\">Marine & Offshore<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Hydrogen & Chlor-Alkali Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Hydrogen & Chlor-Alkali Valves?<\/summary><p>Start with complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records. Add the tag function, failure consequence, interfaces, standards, tests and turnover requirements.<\/p><\/details><details><summary>Which valve type is best for Hydrogen & Chlor-Alkali Valves?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Send the operating cases, not only a valve name<\/h2><p>Attach the datasheet, line class and project requirements. We will separate confirmed inputs from assumptions and identify the checks needed for technical approval.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Hydrogen & Chlor-Alkali Valves\",\"item\":\"https:\/\/raymonvalve.com\/hydrogen-chlor-alkali-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Hydrogen & Chlor-Alkali Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Start with complete chemical composition, concentration, phase, temperature, cleaning fluid and upset conditions, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records. Add the tag function, failure consequence, interfaces, standards, tests and turnover requirements.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Hydrogen & Chlor-Alkali Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Review hydrogen &#038; chlor-alkali valves: service data, construction, materials, operation, tests and RFQ inputs for project-specific valve selection.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13630","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/pages\/13630","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/comments?post=13630"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/pages\/13630\/revisions"}],"predecessor-version":[{"id":13906,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/pages\/13630\/revisions\/13906"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/media?parent=13630"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}