{"id":3760,"date":"2022-08-25T09:14:05","date_gmt":"2022-08-25T01:14:05","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?post_type=product&#038;p=3760"},"modified":"2026-07-29T19:25:20","modified_gmt":"2026-07-29T11:25:20","slug":"pneumatic-high-temperature-and-high-pressure-steam-trap-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/it\/product\/pneumatic-high-temperature-and-high-pressure-steam-trap-valve\/","title":{"rendered":"Valvola di scarico pneumatica per alte temperature e alte pressioni, anti-erosione"},"content":{"rendered":"<div class=\"rv-product-content rvp-content\">\n<section id=\"overview\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Engineering scope<\/div>\n<h2>From product name to an engineered Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve requirement<\/h2>\n<p class=\"rvp-lead\">A Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve is evaluated for modulating process control. A throttling element changes effective flow area in response to a control signal. Installed characteristic, Cv, pressure recovery, trim velocity and actuator resolution determine control quality.<\/p>\n<p>Use the name as a starting point. Technical approval still depends on air-operated actuator sizing, fail action, supply pressure and accessory package; steam or condensate drain duty with flashing, erosion and thermal cycling; protected trim and staged discharge for erosive high-pressure drain service, the complete service envelope, installed interfaces and measurable acceptance.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Pneumatic<\/h3>\n<p>Air-operated actuator sizing, fail action, supply pressure and accessory package. State minimum\/normal air pressure, fail state, stroke time, duty, solenoid, positioner, switches and tubing requirements.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Drain<\/h3>\n<p>Steam or condensate drain duty with flashing, erosion and thermal cycling. Provide upstream\/downstream pressures, temperature, condensate rate, startup\/emergency cases, flashing fraction and discharge layout.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Anti-Scour<\/h3>\n<p>Protected trim and staged discharge for erosive high-pressure drain service. Provide pressure-drop stages, flashing, solids, velocity limits, trim materials, leakage requirement and downstream piping.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Order-specific boundary<\/h3>\n<p>Published information supports initial screening; final size, class, materials, trim, operation, tests and documents are fixed in approved order records.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"published-data\" class=\"rvp-section rvp-legacy-data\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Existing listing data<\/div>\n<h2>Published configuration data for Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve\u2014confirmation required<\/h2>\n<p class=\"rvp-lead\">The values below are transcribed from the previous public product listing so useful model information is not lost during the quality rebuild. They are not a universal available range, certificate or order commitment. Confirm every value in the accepted quotation, tag datasheet and approved drawing.<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Previous listing<\/th>\n<th>Required order check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Product type<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm the exact model, construction and supplied configuration.<\/td>\n<\/tr>\n<tr>\n<td><b>Nominal size \/ DN<\/b><\/td>\n<td>15-100<\/td>\n<td>Confirm each ordered tag and available trim or bore combination.<\/td>\n<\/tr>\n<tr>\n<td><b>Pressure rating<\/b><\/td>\n<td>PN16-420 ANSI Class 150-4500<\/td>\n<td>Confirm governing rating standard, class and temperature basis.<\/td>\n<\/tr>\n<tr>\n<td><b>Temperature<\/b><\/td>\n<td>20~610\u2103<\/td>\n<td>Confirm design, operating, startup and upset metal temperatures.<\/td>\n<\/tr>\n<tr>\n<td><b>End connection<\/b><\/td>\n<td>RF, RJ, BW, SW, etc.<\/td>\n<td>Confirm standard, facing, schedule, bore and mating interface.<\/td>\n<\/tr>\n<tr>\n<td><b>Flow coefficient \/ characteristic<\/b><\/td>\n<td>Quick opening<\/td>\n<td>Confirm calculated cases, trim, travel and installed behavior.<\/td>\n<\/tr>\n<tr>\n<td><b>Body \/ bonnet material<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm component grade, product form, heat treatment and records.<\/td>\n<\/tr>\n<tr>\n<td><b>Trim \/ closure material<\/b><\/td>\n<td>Stainless Steel Optional: &#8211; Oil-free degreasing treatment Features: -It is sealed with metal tooth-shaped gasket or metal round gasket, which has good safety; the valve body is forged as a whole, with reliable performance and guaranteed safety. -The latest ant<\/td>\n<td>Confirm every wetted component, hardness, coating and pairing.<\/td>\n<\/tr>\n<tr>\n<td><b>Seat \/ seal material<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm compatibility, leakage criterion and pressure-temperature limit.<\/td>\n<\/tr>\n<tr>\n<td><b>Operation \/ actuator<\/b><\/td>\n<td>Not stated in the previous public listing.<\/td>\n<td>Confirm worst-case load, fail state, utilities, speed and accessories.<\/td>\n<\/tr>\n<tr>\n<td><b>Leakage basis<\/b><\/td>\n<td>Class V, Class V and Class V Material: -Body, Bonnet: Carbon Steel, Chrome Molybdenum Steel, Stainless Steel<\/td>\n<td>Confirm standard, edition, test direction, medium and measurable acceptance.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\"><b>Evidence boundary:<\/b> where the previous listing was incomplete or awkwardly translated, this page does not guess a value. Raymon Valve should replace provisional web data with the controlled product datasheet when it is available.<\/p>\n<\/div>\n<\/section>\n<section id=\"specifications\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Specification workflow<\/div>\n<h2>Convert process conditions into an auditable valve specification<\/h2>\n<p class=\"rvp-lead\">Use the matrix to close decisions often hidden behind the short description \u201cPneumatic High-Temperature High-Pressure Anti-Scour Drain Valve.\u201d<\/p>\n<div class=\"rvp-tablewrap\">\n<table class=\"rvp-table\">\n<thead>\n<tr>\n<th>Review area<\/th>\n<th>Engineering question<\/th>\n<th>Required record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Sizing cases<\/td>\n<td>Minimum, normal, maximum, startup and upset cases require verified fluid properties and pressures.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<tr>\n<td>Trim duty<\/td>\n<td>Cavitation, flashing, choked gas flow, noise, erosion and rangeability must be evaluated.<\/td>\n<td>Make this requirement auditable through the order datasheet, design review and inspection plan.<\/td>\n<\/tr>\n<tr>\n<td>Actuator<\/td>\n<td>Required thrust or torque, fail action, stroking speed and utility supply must be coordinated.<\/td>\n<td>State the measurable requirement and connect it to a drawing, procedure or test result.<\/td>\n<\/tr>\n<tr>\n<td>Accessories<\/td>\n<td>Positioner, solenoids, limit switches, air set and hazardous-area requirements form one package.<\/td>\n<td>Resolve the open point before release and retain tag-specific evidence in the final dossier.<\/td>\n<\/tr>\n<tr>\n<td>Pneumatic<\/td>\n<td>State minimum\/normal air pressure, fail state, stroke time, duty, solenoid, positioner, switches and tubing requirements.<\/td>\n<td>Name the controlling document, responsible reviewer and inspection or calculation record.<\/td>\n<\/tr>\n<tr>\n<td>Drain<\/td>\n<td>Provide upstream\/downstream pressures, temperature, condensate rate, startup\/emergency cases, flashing fraction and discharge layout.<\/td>\n<td>Freeze the accepted value in the tag datasheet and verify it on the approved drawing.<\/td>\n<\/tr>\n<tr>\n<td>Anti-Scour<\/td>\n<td>Provide pressure-drop stages, flashing, solids, velocity limits, trim materials, leakage requirement and downstream piping.<\/td>\n<td>Capture the selection basis, approved deviation if any and the record used for acceptance.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"rvp-note\">Record exact standard designations and contract editions; resolve scope gaps and purchaser options before manufacture.<\/p>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"rvp-section rvp-dark\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Application boundaries<\/div>\n<h2>Failure exposures behind the nominal configuration<\/h2>\n<p>Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The final decision must cover system interactions, end-of-life loads, degradation and how failure will be detected or contained.<\/p>\n<div class=\"rvp-checks\">\n<div class=\"rvp-check\">Complete medium composition, pressure, temperature and flow cases for the Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve<\/div>\n<div class=\"rvp-check\">Valve role, operating cycles, permitted leakage, safe state and consequence of failure<\/div>\n<div class=\"rvp-check\">Piping class, mating ends, bore, installed length, orientation, loads and maintenance clearance<\/div>\n<div class=\"rvp-check\">Corrosion and wear basis with exact body, trim, sealing, bolting, overlay, lining or coating materials<\/div>\n<div class=\"rvp-check\">Manual or actuated operation, maximum load, fail action, speed, utilities and accessories<\/div>\n<div class=\"rvp-check\">Product, rating, dimensions, ends and test requirements plus special qualification and tag-linked evidence<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Evidence and quality<\/div>\n<h2>Request evidence that matches the supplied design<\/h2>\n<p class=\"rvp-lead\">A certificate or report is useful only when its scope traces to the actual tag, materials and configuration. Use the <a href=\"\/valve-standards\/\">valve standards guide<\/a> to separate product, rating, dimensional, end-connection and test scope.<\/p>\n<div class=\"rvp-grid\">\n<div class=\"rvp-card\">\n<h3>Design basis<\/h3>\n<p>Tag requirements, design review, materials list and approved exception register.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Material identity<\/h3>\n<p>Component certificates, heat or lot traceability, heat treatment, hardness and required PMI or NDE.<\/p>\n<\/div>\n<div class=\"rvp-card\">\n<h3>Inspection and tests<\/h3>\n<p>Approved ITP, procedures, calibrated instruments, results, witness records and NCR closeout.<\/p>\n<\/div>\n<\/div>\n<p>Size at minimum available supply pressure and maximum valve load. Drain-valve selection must include the downstream flashing line and thermal-transient duty. Anti-scour claims require geometry, material and operating evidence for the actual duty.<\/p>\n<p>Do not infer certification or guaranteed performance from this page. Accept only the order-specific evidence required by the purchaser.<\/p>\n<\/div>\n<\/section>\n<section id=\"rfq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">RFQ checklist<\/div>\n<h2>RFQ inputs that remove avoidable assumptions<\/h2>\n<p>Send tag identity, quantity, fluid, all design and operating cases, line interface, function, flow data, materials, operation, testing, inspection and turnover scope.<\/p>\n<p>For a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve, also highlight air-operated actuator sizing, fail action, supply pressure and accessory package; steam or condensate drain duty with flashing, erosion and thermal cycling; protected trim and staged discharge for erosive high-pressure drain service. Identify missing inputs and provisional selections so they can be closed before purchase order release.<\/p>\n<div class=\"rvp-cta\">\n<div>\n<h2>Ask for a configuration tied to the real duty<\/h2>\n<p>Send the valve list and project requirements. Raymon Valve will identify missing inputs, clarify construction and return an order-specific quotation basis.<\/p>\n<\/div>\n<div class=\"rvp-actions\"><a class=\"rvp-btn rvp-btn-primary\" href=\"\/contact\/\">Submit Your Datasheet<\/a><a class=\"rvp-btn rvp-btn-ghost\" href=\"\/control-valves\/\">Compare Control Valve Options<\/a><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">Related engineering route<\/div>\n<h2>Continue the selection review<\/h2>\n<div class=\"rvp-grid\"><a class=\"rvp-card\" href=\"\/control-valves\/\"><\/p>\n<h3>Product family<\/h3>\n<p>Compare the main constructions and selection boundaries in this valve family.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-solutions\/\"><\/p>\n<h3>Project Valve Review<\/h3>\n<p>Resolve interacting pressure, temperature, corrosion, wear or project risks.<\/p>\n<p><\/a><a class=\"rvp-card\" href=\"\/valve-pressure-testing\/\"><\/p>\n<h3>Testing and inspection<\/h3>\n<p>Define pressure-test scope, acceptance, instruments, witness points and records.<\/p>\n<p><\/a><\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-CSS-START --><\/p>\n<style id=\"rvq-quality-css\">.rvq-section{padding:68px 0;font-family:Arial,Helvetica,sans-serif;color:#17233a;line-height:1.7}.rvq-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rvq-intent{background:#f4f7fb}.rvq-trust{background:#fff}.rvq-kicker{color:#07549a;font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rvq-section h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:#0b1731}.rvq-lead{max-width:900px;color:#5c6779;font-size:17px}.rvq-tablewrap{overflow-x:auto;margin-top:28px;border:1px solid #dfe5ee;border-radius:12px;background:#fff}.rvq-table{width:100%;border-collapse:collapse;min-width:760px}.rvq-table th{background:#07549a;color:#fff;text-align:left;padding:15px}.rvq-table td{padding:15px;border-bottom:1px solid #dfe5ee;vertical-align:top}.rvq-table tr:last-child td{border-bottom:0}.rvq-source,.rvq-boundary{margin-top:22px;padding:20px;border-left:5px solid #f3cc18;background:#fff8d8;border-radius:8px}.rvq-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin:25px 0}.rvq-grid>div{border:1px solid #dfe5ee;border-radius:10px;padding:18px;background:#f8fafc}.rvq-grid b,.rvq-grid span{display:block}.rvq-grid b{color:#07549a;margin-bottom:5px}.rvq-grid span{font-size:14px;color:#5c6779}@media(max-width:800px){.rvq-grid{grid-template-columns:1fr 1fr}}@media(max-width:520px){.rvq-wrap{width:min(100% - 28px,1160px)}.rvq-section{padding:50px 0}.rvq-grid{grid-template-columns:1fr}}<\/style>\n<p><!-- RVQ-CSS-END --><!-- RVQ-INTENT-START --><\/p>\n<section class=\"rvq-section rvq-intent\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Task-specific answer<\/div>\n<h2>Convert Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve from a broad request into an auditable engineering decision<\/h2>\n<p class=\"rvq-lead\">This section addresses the decision a visitor is likely trying to complete\u2014not merely the meaning of the page title. Use it to identify required inputs, compare the proposal and specify the record that will prove acceptance.<\/p>\n<div class=\"rvq-tablewrap\">\n<table class=\"rvq-table\">\n<thead>\n<tr>\n<th>Decision<\/th>\n<th>What to do<\/th>\n<th>Evidence to retain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Problem statement<\/b><\/td>\n<td>For Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve, define the required system outcome, failure consequence and measurable acceptance before choosing hardware.<\/td>\n<td>Functional requirement<\/td>\n<\/tr>\n<tr>\n<td><b>Feasible routes<\/b><\/td>\n<td>Compare at least the practical construction, material, sealing and actuation alternatives, including reasons for rejection.<\/td>\n<td>Option and trade-off matrix<\/td>\n<\/tr>\n<tr>\n<td><b>Boundary conditions<\/b><\/td>\n<td>Check every normal, transient, startup, shutdown, maintenance and utility-loss case that can change the solution.<\/td>\n<td>Approved application data<\/td>\n<\/tr>\n<tr>\n<td><b>Validation<\/b><\/td>\n<td>Connect each claimed benefit to a calculation, drawing, qualification, inspection or package-level test that applies to the order.<\/td>\n<td>Verification and evidence plan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rvq-boundary\"><b>Decision boundary:<\/b> This guidance supports screening and RFQ preparation. Final suitability, compliance and supplied scope require the actual application data, governing jurisdiction, contract documents, approved supplier submittals and tag-linked records.<\/div>\n<\/div>\n<\/section>\n<p><!-- RVQ-INTENT-END --><!-- RVQ-TRUST-START --><\/p>\n<section class=\"rvq-section rvq-trust\">\n<div class=\"rvq-wrap\">\n<div class=\"rvq-kicker\">Content responsibility &amp; evidence<\/div>\n<h2>How this Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve guide should be used<\/h2>\n<div class=\"rvq-grid\">\n<div><b>Publisher<\/b><span>Raymon Valve technical content team<\/span><\/div>\n<div><b>Purpose<\/b><span>Engineering screening, specification and RFQ preparation<\/span><\/div>\n<div><b>Content update<\/b><span>29 July 2026<\/span><\/div>\n<div><b>Verification level<\/b><span>Topic scope, search intent and evidence boundaries checked<\/span><\/div>\n<\/div>\n<p>This page does not claim that a named person, certificate, qualification, installed project or performance result applies to a future order. Product compliance is confirmed only when the accepted quotation, approved drawing, procedures and final manufacturing\/test records identify the supplied configuration.<\/p>\n<p>Technical requirements and standards can change. Verify the official source, contract edition, project precedence and purchaser options. See our <a href=\"\/technical-content-review-policy\/\">technical content review and evidence policy<\/a>, <a href=\"\/about-us\/\">company information<\/a>, <a href=\"\/valve-inspection\/\">inspection approach<\/a> or <a href=\"\/contact\/\">submit a correction or application question<\/a>.<\/p>\n<\/div>\n<\/section>\n<p><!-- RVQ-TRUST-END --><!-- RVQ-SCHEMA-START --><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"WebPage\",\"name\":\"Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve\",\"url\":\"https:\/\/raymonvalve.com\/product\/pneumatic-high-temperature-and-high-pressure-steam-trap-valve\/\",\"dateModified\":\"2026-07-29\",\"description\":\"Product selection guide for Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve, with application boundaries, decision inputs and order-specific evidence requirements.\",\"publisher\":{\"@type\":\"Organization\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"isPartOf\":{\"@type\":\"WebSite\",\"name\":\"Raymon Valve\",\"url\":\"https:\/\/raymonvalve.com\/\"},\"about\":{\"@type\":\"Thing\",\"name\":\"Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve\"}}<\/script><!-- RVQ-SCHEMA-END --><\/p>\n<section id=\"faq\" class=\"rvp-section\">\n<div class=\"rvp-wrap\">\n<div class=\"rvp-kicker\">FAQ<\/div>\n<h2>Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve questions<\/h2>\n<div class=\"rvp-faq\">\n<details>\n<summary>What information is required to select a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve?<\/summary>\n<p>Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address air-operated actuator sizing, fail action, supply pressure and accessory package; steam or condensate drain duty with flashing, erosion and thermal cycling; protected trim and staged discharge for erosive high-pressure drain service.<\/p>\n<\/details>\n<details>\n<summary>Which standards apply to a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve?<\/summary>\n<p>The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Size at minimum available supply pressure and maximum valve load. Drain-valve selection must include the downstream flashing line and thermal-transient duty. Anti-scour claims require geometry, material and operating evidence for the actual duty.<\/p>\n<\/details>\n<details>\n<summary>How should Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve pressure and leakage testing be specified?<\/summary>\n<p>State the governing standard and approved edition, shell and closure basis, medium, pressure, duration, leakage acceptance, directionality, instruments, witness points and report format.<\/p>\n<\/details>\n<details>\n<summary>Can a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve be supplied with an actuator?<\/summary>\n<p>Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.<\/p>\n<\/details>\n<details>\n<summary>When should a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve not be selected?<\/summary>\n<p>Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The alternative should be chosen only after comparing the complete service duty.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What information is required to select a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address air-operated actuator sizing, fail action, supply pressure and accessory package; steam or condensate drain duty with flashing, erosion and thermal cycling; protected trim and staged discharge for erosive high-pressure drain service.\"}}, {\"@type\": \"Question\", \"name\": \"Which standards apply to a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. Size at minimum available supply pressure and maximum valve load. Drain-valve selection must include the downstream flashing line and thermal-transient duty. Anti-scour claims require geometry, material and operating evidence for the actual duty.\"}}, {\"@type\": \"Question\", \"name\": \"How should Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve pressure and leakage testing be specified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"State the governing standard and approved edition, shell and closure basis, medium, pressure, duration, leakage acceptance, directionality, instruments, witness points and report format.\"}}, {\"@type\": \"Question\", \"name\": \"Can a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve be supplied with an actuator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Automation requires more than matching a mounting flange. Verify maximum load through travel, minimum supply, coupling\/stem capacity, stops, controls and required failure response.\"}}, {\"@type\": \"Question\", \"name\": \"When should a Pneumatic High-Temperature High-Pressure Anti-Scour Drain Valve not be selected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Do not size a control valve from pipe diameter alone; incorrect Cv can cause poor resolution, noise, cavitation or premature trim damage. The alternative should be chosen only after comparing the complete service duty.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Valvola di scarico pneumatica antideflagrante per alte temperature e alte pressioni per controllo di processo modulante definito dal progetto. La selezione considera il dimensionamento dell'attuatore ad aria, l'azione di sicurezza, la pressione di alimentazione e il pacchetto accessori; servizio di scarico vapore o condensa con flashing, erosione e cicli termici; trim protetto e scarico a stadi per servizio di scarico ad alta pressione erosiva, materiali, funzionamento, collaudo e accettazione documentata prima del rilascio del preventivo.<\/p>","protected":false},"featured_media":3759,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[178,311,196,297],"product_tag":[],"class_list":["post-3760","product","type-product","status-publish","has-post-thumbnail","product_cat-control-valves","product_cat-high-temperature-and-high-pressure-valve","product_cat-power-station-valve","product_cat-power-station-high-differential-pressure-control-valve","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal-slider","ast-product-gallery-with-no-image","ast-product-tabs-layout-horizontal","ast-qv-on-image","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/product\/3760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/comments?post=3760"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/media\/3759"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/media?parent=3760"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/product_brand?post=3760"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/product_cat?post=3760"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/it\/wp-json\/wp\/v2\/product_tag?post=3760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}