{"id":3725,"date":"2022-08-24T11:29:47","date_gmt":"2022-08-24T03:29:47","guid":{"rendered":"https:\/\/limegreen-okapi-448594.hostingersite.com\/?post_type=product&#038;p=3725"},"modified":"2022-09-05T10:59:45","modified_gmt":"2022-09-05T02:59:45","slug":"boiler-continuous-blowdown-control-valve","status":"publish","type":"product","link":"https:\/\/raymonvalve.com\/pt\/produto\/boiler-continuous-blowdown-control-valve\/","title":{"rendered":"V\u00e1lvula de controle de purga cont\u00ednua de caldeira"},"content":{"rendered":"<p>Principalmente utilizada em usinas de energia para remover continuamente parte do sal dissolvido na \u00e1gua da caldeira. \u00c9 uma das v\u00e1lvulas chave em usinas de energia para controlar \u00e1gua saturada com alta diferen\u00e7a de press\u00e3o. Tamb\u00e9m pode ser usada nas ind\u00fastrias de petr\u00f3leo e qu\u00edmica para controlar a vaz\u00e3o de l\u00edquido saturado com alta queda de press\u00e3o.<\/p>\n<p>Dados t\u00e9cnicos:<\/p>\n<p>-DN: 20-100<br \/>\n-Press\u00e3o: PN250-420<br \/>\nANSI Classe 900-2500<br \/>\n-Padr\u00e3o de conex\u00e3o: RF, RJ, BW, pad de lente -Temperatura: -20\u2103~+420\u2103 -Caracter\u00edstica de fluxo: Caracter\u00edstica parab\u00f3lica -Vazamento: Classe IV<\/p>\n<p>Material:<\/p>\n<p>\u2013 Corpo da v\u00e1lvula: Forjado 20#<br \/>\n\u2013 Internos: a\u00e7o inoxid\u00e1vel endurecido com nitreto<\/p>\n<p>Opcional:<\/p>\n<p>nenhum<\/p>\n<p>Caracter\u00edsticas:<\/p>\n<p>-Tipo angular forjado, corpo de v\u00e1lvula tipo Z<br \/>\n\u2013 O fluido \u00e9 despressurizado passo a passo, a dire\u00e7\u00e3o do fluido \u00e9 continuamente alterada, a resist\u00eancia ao fluxo \u00e9 aumentada, a vaz\u00e3o \u00e9 controlada e o dano por cavita\u00e7\u00e3o ao fluido \u00e9 evitado. A diferen\u00e7a de press\u00e3o permitida no intervalo \u00e9 de 25MPa<br \/>\n-Projeto de estrangulamento multiest\u00e1gio<br \/>\n-A superf\u00edcie de estrangulamento \u00e9 separada da superf\u00edcie de veda\u00e7\u00e3o, e a superf\u00edcie \u00e9 endurecida. -Design anti-seize para part\u00edculas s\u00f3lidas<br \/>\n\u2013 Pe\u00e7as comuns, boa intercambialidade<\/p>","protected":false},"excerpt":{"rendered":"<p>Principalmente utilizada em usinas de energia para remover continuamente parte do sal dissolvido na \u00e1gua da caldeira. \u00c9 uma das v\u00e1lvulas chave em usinas de energia para controlar \u00e1gua saturada com alta diferen\u00e7a de press\u00e3o. Tamb\u00e9m pode ser usada nas ind\u00fastrias de petr\u00f3leo e qu\u00edmica para controlar a vaz\u00e3o de l\u00edquido saturado com alta queda de press\u00e3o.<\/p>","protected":false},"featured_media":3727,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[178,196,297],"product_tag":[],"class_list":{"0":"post-3725","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-control-valves","7":"product_cat-power-station-valve","8":"product_cat-power-station-high-differential-pressure-control-valve","9":"desktop-align-left","10":"tablet-align-left","11":"mobile-align-left","12":"ast-product-gallery-layout-horizontal-slider","13":"ast-product-gallery-with-no-image","14":"ast-product-tabs-layout-horizontal","15":"ast-qv-on-image","17":"first","18":"instock","19":"shipping-taxable","20":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/product\/3725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/comments?post=3725"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/media\/3727"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/media?parent=3725"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/product_brand?post=3725"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/product_cat?post=3725"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/raymonvalve.com\/pt\/wp-json\/wp\/v2\/product_tag?post=3725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}