{"id":13628,"date":"2026-07-27T22:02:51","date_gmt":"2026-07-27T14:02:51","guid":{"rendered":"https:\/\/raymonvalve.com\/hvac-building-service-valves\/"},"modified":"2026-07-27T22:38:45","modified_gmt":"2026-07-27T14:38:45","slug":"hvac-building-service-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ru\/hvac-building-service-valves\/","title":{"rendered":"\u041a\u043b\u0430\u043f\u0430\u043d\u044b \u0434\u043b\u044f \u041e\u0412\u041a \u0438 \u0441\u0435\u0440\u0432\u0438\u0441\u043d\u043e\u0433\u043e \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u044f \u0437\u0434\u0430\u043d\u0438\u0439"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13628\" class=\"elementor elementor-13628 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc28e4ee e-con-full e-flex e-con e-parent\" data-id=\"cc28e4ee\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53f78b10 elementor-widget elementor-widget-html\" data-id=\"53f78b10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ HVAC & Building Service Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>HVAC & Building Service Valves: Application and Selection Guide<\/h1><p>HVAC & Building Service Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Turn the search question into controlled project inputs<\/h2><p class=\"rv-lead\">For hvac & building service valves, the first review should cover design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method. The practical audience is application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system. Every recommendation remains conditional on the approved application and supplied records.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Chilled and hot water<\/b><p>Convert this subject into measurable requirements, review points and tag-linked evidence instead of leaving it as a brochure description.<\/p><\/div><div class=\"rv-card\"><b>02. Heat-exchanger isolation<\/b><p>Record the governing data, open questions, owner of each interface and the verification activity needed before manufacture.<\/p><\/div><div class=\"rv-card\"><b>03. Pump discharge and bypass<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>04. Building-management control loops<\/b><p>Record the governing data, open questions, owner of each interface and the verification activity needed before manufacture.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Use this framework with the governing datasheet and project documents. It is not a substitute for tag-specific engineering approval.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Build a requirement-to-evidence matrix for the tag<\/h2><p class=\"rv-lead\">Review each decision area across disciplines, record deviations and require proof that applies to the proposed configuration.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>State the required action of hvac & building service valves during normal operation, startup, trip, shutdown and loss of utility.<\/td><td>Controlled tag description, system narrative and cause-and-effect where relevant<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Describe the medium and boundaries in enough detail to evaluate hvac & building service valves without hidden service assumptions.<\/td><td>Process datasheet, composition, phase, contaminants and design envelope<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Confirm that the proposed valve physically and functionally fits the piping rather than matching only size and class.<\/td><td>Interface matrix covering ends, facing, bore, length, loads, clearance and orientation<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Coordinate operating frequency, speed, fail behavior, local override, signal and hazardous-area requirements.<\/td><td>Approved package datasheet, logic\/interface record and witnessed functional results where required<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Agree design review, NDE, pressure and leakage tests, special qualifications, intervention points and final records.<\/td><td>Approved ITP, procedures, calibrated results and tag-linked manufacturing record book<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Application exposures to resolve before release<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Hydraulic instability<\/b><p>Close the exposure with project data, a technically reviewed supplier response and an objective inspection or performance criterion.<\/p><\/div><div class=\"rv-card\"><b>Water hammer<\/b><p>Close the exposure with project data, a technically reviewed supplier response and an objective inspection or performance criterion.<\/p><\/div><div class=\"rv-card\"><b>Actuator and service access<\/b><p>Close the exposure with project data, a technically reviewed supplier response and an objective inspection or performance criterion.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">Six steps from application question to released order<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Translate the need for hvac & building service valves into a tag function and measurable acceptance criteria.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Build a controlled application-data set and flag every unknown that could change materials, sizing or operation.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Compare feasible valve families, constructions, materials and actuation routes before selecting a catalog model.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Quantify loads and performance limits instead of relying on nominal size, commercial labels or past habit.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Cross-check the supplier proposal with the datasheet, line class, project standards and risk register.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Close deviations and retain tag-linked manufacturing, test, inspection and turnover evidence.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Data needed before price and delivery can be compared fairly<\/h2><p class=\"rv-lead\">Complete inputs let the supplier identify deviations, calculate loads and issue drawings and an inspection plan against one controlled requirement.<\/p><ul class=\"rv-check\"><li>Search question converted into a project requirement for HVAC & Building Service Valves<\/li><li>Tag identity, required action and safe state<\/li><li>Design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Pressure-temperature cases with differential pressure and duration where relevant<\/li><li>Fluid composition, phase, solids, contaminants and cleaning media<\/li><li>Mechanical interfaces, allowable loads, operator position and maintenance space<\/li><li>Body, trim, seat, sealing, bolting, coating or lining materials<\/li><li>Operator load, cycle frequency, speed, safe position, power\/air and control interfaces<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>Pressure, leakage, functional, NDE and special test acceptance criteria<\/li><li>Inspection points, document index, certificates, spares and delivery requirements<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Marketing content can explain a route, but only controlled drawings, calculations, certificates, procedures and results can close an order requirement.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Use the next pages to narrow product and evidence scope<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/commercial-building-valves\/\">Commercial Building Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/acid-solvent-service-valves\/\">Solvent & Acid Service Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/renewable-energy-valves\/\">Renewable Energy Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about HVAC & Building Service Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate HVAC & Building Service Valves?<\/summary><p>Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for HVAC & Building Service Valves?<\/summary><p>First classify the function, then compare constructions using media, pressure-temperature cases, flow behavior, cycling, consequence and access. A catalog family should be the result of that review.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>Initial guidance is possible, but a responsible recommendation requires the real process envelope, valve function and project requirements. Unknowns will be listed for closure.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Send the operating cases, not only a valve name<\/h2><p>Share fluid details, pressure-temperature and flow cases, piping interfaces, operation, standards, tests and documents. Raymon Valve can return a clarified route and open-point list.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HVAC & Building Service Valves\",\"item\":\"https:\/\/raymonvalve.com\/hvac-building-service-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate HVAC & Building Service Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide design and part-load flow, pressure zones, allowable pressure drop, control signal and commissioning method, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for HVAC & Building Service Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"First classify the function, then compare constructions using media, pressure-temperature cases, flow behavior, cycling, consequence and access. A catalog family should be the result of that review.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial guidance is possible, but a responsible recommendation requires the real process envelope, valve function and project requirements. Unknowns will be listed for closure.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Review hvac &#038; building service valves: service data, construction, materials, operation, tests and RFQ inputs for project-specific valve selection.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13628","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=13628"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13628\/revisions"}],"predecessor-version":[{"id":13904,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13628\/revisions\/13904"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=13628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}