{"id":13638,"date":"2026-07-27T22:03:27","date_gmt":"2026-07-27T14:03:27","guid":{"rendered":"https:\/\/raymonvalve.com\/municipal-water-valves\/"},"modified":"2026-07-27T22:39:22","modified_gmt":"2026-07-27T14:39:22","slug":"municipal-water-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ru\/municipal-water-valves\/","title":{"rendered":"\u041a\u043b\u0430\u043f\u0430\u043d\u044b \u0434\u043b\u044f \u0433\u043e\u0440\u043e\u0434\u0441\u043a\u043e\u0433\u043e \u0432\u043e\u0434\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13638\" class=\"elementor elementor-13638 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4a45cc82 e-con-full e-flex e-con e-parent\" data-id=\"4a45cc82\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5cd76d39 elementor-widget elementor-widget-html\" data-id=\"5cd76d39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valves-involved-industries\/\">Industries<\/a> \/ Municipal Water Valves<\/div><div class=\"rv-kicker\">Industry application<\/div><h1>Municipal Water Valves: Application and Selection Guide<\/h1><p>Municipal Water Valves are not selected from a valve family name alone. Each tag must be tied to its process function, fluid, operating cases, failure consequence and maintenance plan. This engineering guide organizes the systems, risks and RFQ inputs that should be resolved before a supplier proposal is approved.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Start with the engineering decision, not a catalog label<\/h2><p class=\"rv-lead\">For municipal water valves, the first review should cover water quality, solids content, hydraulic profile, pump transient and allowable head loss. The practical audience is application engineers, EPC teams and procurement specialists comparing valve routes for a defined plant system. Every recommendation remains conditional on the approved application and supplied records.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Raw-water intake<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>02. Pump stations<\/b><p>Document the duty cases, physical interfaces, decision limits and the record that will demonstrate acceptance before technical release.<\/p><\/div><div class=\"rv-card\"><b>03. Treatment and chemical dosing<\/b><p>Treat this as an engineering decision with controlled inputs, stated assumptions, approved limits and a traceable closeout record.<\/p><\/div><div class=\"rv-card\"><b>04. Distribution or discharge<\/b><p>Convert this subject into measurable requirements, review points and tag-linked evidence instead of leaving it as a brochure description.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Use this framework with the governing datasheet and project documents. It is not a substitute for tag-specific engineering approval.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Build a requirement-to-evidence matrix for the tag<\/h2><p class=\"rv-lead\">Review each decision area across disciplines, record deviations and require proof that applies to the proposed configuration.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Separate isolation, regulation, non-return and protective functions for municipal water valves; assign acceptance for each.<\/td><td>Datasheet function, line list and functional requirement approved by the responsible engineer<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Water quality, solids content, hydraulic profile, pump transient and allowable head loss<\/td><td>Datasheet with units and minimum, normal, maximum, startup and upset values<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Check the installed connection, flow direction, support loads, operator envelope and future removal path.<\/td><td>Piping isometric, interface dimensions and marked-up supplier drawing<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Use worst-case valve load and minimum utility to engineer the operator, controls, indication and safe response.<\/td><td>Torque\/thrust basis, actuator sizing, accessories list and package test procedure<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Agree design review, NDE, pressure and leakage tests, special qualifications, intervention points and final records.<\/td><td>Approved ITP, procedures, calibrated results and tag-linked manufacturing record book<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Where incomplete requirements become valve failures<\/h2><p class=\"rv-lead\">Priority depends on the real operating case and consequence, but the following exposures deserve explicit review for this topic.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Surge and check-valve slam<\/b><p>Close the exposure with project data, a technically reviewed supplier response and an objective inspection or performance criterion.<\/p><\/div><div class=\"rv-card\"><b>Coating and corrosion<\/b><p>Record the residual risk after design review and make the relevant drawing, procedure or test result part of the tag dossier.<\/p><\/div><div class=\"rv-card\"><b>Solids or biological fouling<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Technical approval should connect each important risk to construction, material, calculation, qualification and tag-level evidence.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">How to move from open question to approved valve tag<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for municipal water valves that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially water quality, solids content, hydraulic profile, pump transient and allowable head loss.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Quantify loads and performance limits instead of relying on nominal size, commercial labels or past habit.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Review drawings, calculations, materials, qualification scope and inspection plan against the controlled specification.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Close deviations and retain tag-linked manufacturing, test, inspection and turnover evidence.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">Data needed before price and delivery can be compared fairly<\/h2><p class=\"rv-lead\">A disciplined inquiry improves technical comparability, reveals exclusions and reduces changes after purchase order placement.<\/p><ul class=\"rv-check\"><li>Review purpose and decision owner confirmed for Municipal Water Valves<\/li><li>System boundary, operating role and criticality classification<\/li><li>Water quality, solids content, hydraulic profile, pump transient and allowable head loss<\/li><li>Minimum, normal, maximum, startup, shutdown and upset cases<\/li><li>Minimum\/normal\/maximum process cases and all design transients<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Piping class, mating connection, bore, length, loads, access and removal clearance<\/li><li>Body, trim, seat, sealing, bolting, coating or lining materials<\/li><li>Manual or automated duty, torque\/thrust basis, fail state and utilities<\/li><li>Governing code, product\/test standards, owner clauses and approved deviations<\/li><li>ITP intervention points plus material, NDE, pressure, leakage and package tests<\/li><li>Inspection points, document index, certificates, spares and delivery requirements<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Acceptance evidence must match the supplied configuration, tag, revision and agreed scope. Retain it in the final document index.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Continue the review with product and quality pages<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valves-involved-industries\/\">Industries<small>Return to the industries hub.<\/small><\/a><a class=\"rv-link\" href=\"\/water-treatment-valves\/\">Water Treatment Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/water-utilities\/\">Water & Utilities<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/water-conservancy-valves\/\">Water Conservancy Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Municipal Water Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Municipal Water Valves?<\/summary><p>The minimum review set covers water quality, solids content, hydraulic profile, pump transient and allowable head loss, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records; missing controlling cases should be identified as open points, not silently assumed.<\/p><\/details><details><summary>Which valve type is best for Municipal Water Valves?<\/summary><p>First classify the function, then compare constructions using media, pressure-temperature cases, flow behavior, cycling, consequence and access. A catalog family should be the result of that review.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Evidence should mirror the risk and specification: approved design documents, traceable materials, controlled procedures, calibrated results, closed nonconformances and a searchable final index.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Give engineering enough information to challenge assumptions<\/h2><p>Provide the tag function, complete service envelope, installation, actuation and evidence scope so the response can address the actual project rather than a generic valve label.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\/\/raymonvalve.com\/valves-involved-industries\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Municipal Water Valves\",\"item\":\"https:\/\/raymonvalve.com\/municipal-water-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Municipal Water Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The minimum review set covers water quality, solids content, hydraulic profile, pump transient and allowable head loss, minimum, normal, maximum, startup, shutdown and upset cases, size, rating, ends, flow direction, installation orientation and available space, materials, sealing, actuation, tests, inspection points and required records; missing controlling cases should be identified as open points, not silently assumed.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Municipal Water Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"First classify the function, then compare constructions using media, pressure-temperature cases, flow behavior, cycling, consequence and access. A catalog family should be the result of that review.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Evidence should mirror the risk and specification: approved design documents, traceable materials, controlled procedures, calibrated results, closed nonconformances and a searchable final index.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u041e\u0431\u0437\u043e\u0440 \u043a\u043b\u0430\u043f\u0430\u043d\u043e\u0432 \u0434\u043b\u044f \u043a\u043e\u043c\u043c\u0443\u043d\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0432\u043e\u0434\u043e\u0441\u043d\u0430\u0431\u0436\u0435\u043d\u0438\u044f: \u0434\u0430\u043d\u043d\u044b\u0435 \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438, \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f, \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u0440\u0430\u0431\u043e\u0442\u0430, \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438 \u0432\u0445\u043e\u0434\u043d\u044b\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 RFQ \u0434\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043b\u0430\u043f\u0430\u043d\u043e\u0432 \u043f\u043e\u0434 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0439 \u043f\u0440\u043e\u0435\u043a\u0442.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13638","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13638","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=13638"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13638\/revisions"}],"predecessor-version":[{"id":13914,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13638\/revisions\/13914"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=13638"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}