{"id":13662,"date":"2026-07-27T22:06:23","date_gmt":"2026-07-27T14:06:23","guid":{"rendered":"https:\/\/raymonvalve.com\/slurry-valves\/"},"modified":"2026-07-27T22:40:57","modified_gmt":"2026-07-27T14:40:57","slug":"slurry-valves","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ru\/slurry-valves\/","title":{"rendered":"\u041a\u043b\u0430\u043f\u0430\u043d\u044b \u0434\u043b\u044f \u0440\u0430\u0431\u043e\u0442\u044b \u0441\u043e \u0448\u043b\u0430\u043c\u043e\u043c"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13662\" class=\"elementor elementor-13662 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c274cfec e-con-full e-flex e-con e-parent\" data-id=\"c274cfec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b4474846 elementor-widget elementor-widget-html\" data-id=\"b4474846\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/corrosion-resistant-working-condition\/\">Materials & Corrosion<\/a> \/ Slurry Service Valves<\/div><div class=\"rv-kicker\">Materials engineering<\/div><h1>Slurry Service Valves: Materials Selection and Valve Specification<\/h1><p>Slurry Service Valves may be considered for abrasive, settling or solids-bearing service, but material name alone never proves valve suitability. Pressure boundary, trim, seats, packing, bolting, welds and coatings must be reviewed separately against the actual environment and manufacturing route.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Turn the search question into controlled project inputs<\/h2><p class=\"rv-lead\">Hardness alone does not determine life. Impact, corrosion, geometry, velocity and repair strategy must be reviewed together. The practical audience is materials, corrosion and procurement engineers evaluating a documented alloy route for a specific valve tag. Every recommendation remains conditional on the approved application and supplied records.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Define the environment for wear-resistant material and flow-path system<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>02. Map every wetted and pressure-containing component<\/b><p>Resolve normal and abnormal conditions, installation boundaries and acceptance evidence before a catalog construction is selected.<\/p><\/div><div class=\"rv-card\"><b>03. Control fabrication, welding and heat treatment<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>04. Verify identity, inspection and tag-level traceability<\/b><p>Define what success means for this item, then connect the requirement to a drawing, calculation, inspection or functional result.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Service, jurisdiction, project specification and construction can change the result; verify current standards, calculations and supplier documents.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Translate application data into a reviewable valve requirement<\/h2><p class=\"rv-lead\">Review each decision area across disciplines, record deviations and require proof that applies to the proposed configuration.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>State the required action of slurry service valves during normal operation, startup, trip, shutdown and loss of utility.<\/td><td>Controlled tag description, system narrative and cause-and-effect where relevant<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Describe the medium and boundaries in enough detail to evaluate slurry service valves without hidden service assumptions.<\/td><td>Process datasheet, composition, phase, contaminants and design envelope<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Confirm that the proposed valve physically and functionally fits the piping rather than matching only size and class.<\/td><td>Interface matrix covering ends, facing, bore, length, loads, clearance and orientation<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>Coordinate operating frequency, speed, fail behavior, local override, signal and hazardous-area requirements.<\/td><td>Approved package datasheet, logic\/interface record and witnessed functional results where required<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Agree design review, NDE, pressure and leakage tests, special qualifications, intervention points and final records.<\/td><td>Approved ITP, procedures, calibrated results and tag-linked manufacturing record book<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Where incomplete requirements become valve failures<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Environmental cracking or localized corrosion<\/b><p>The proposal should explain the design safeguard, identify its limit and point to the order record that verifies it.<\/p><\/div><div class=\"rv-card\"><b>Mixed-material and fabrication errors<\/b><p>Tie mitigation to the actual operating case and verify it through calculation, qualification, inspection or package-level testing.<\/p><\/div><div class=\"rv-card\"><b>Unverified grade identity or heat treatment<\/b><p>Evaluate likelihood and consequence for the real service, then specify the construction feature and evidence needed to control it.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">Six steps from application question to released order<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Translate the need for slurry service valves into a tag function and measurable acceptance criteria.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Collect particle size, shape and hardness, solids concentration and velocity; record assumptions and missing cases.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Test the proposed route against every controlling case with documented methods and conservative assumptions.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Resolve deviations and verify interfaces, acceptance methods and evidence before manufacturing release.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Release only the approved configuration and preserve its revision, inspections and final records in the tag dossier.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">RFQ inputs that remove avoidable supplier assumptions<\/h2><p class=\"rv-lead\">Complete inputs let the supplier identify deviations, calculate loads and issue drawings and an inspection plan against one controlled requirement.<\/p><ul class=\"rv-check\"><li>Search question converted into a project requirement for Slurry Service Valves<\/li><li>System boundary, operating role and criticality classification<\/li><li>Particle size, shape and hardness<\/li><li>Solids concentration and velocity<\/li><li>Minimum\/normal\/maximum process cases and all design transients<\/li><li>Media constituents, concentration, phase behavior, impurities and cleaning exposure<\/li><li>Size, rating, ends, flow direction, orientation and installation envelope<\/li><li>Corrosion\/wear basis and the specified material for each pressure, wetted and sealing part<\/li><li>Manual or automated duty, torque\/thrust basis, fail state and utilities<\/li><li>Document hierarchy, exact standard designations, editions and project supplements<\/li><li>Inspection methods, sampling, test configuration, instruments and acceptance limits<\/li><li>Tag-linked record book, manuals, preservation, spares, logistics and handover date<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Acceptance evidence must match the supplied configuration, tag, revision and agreed scope. Retain it in the final document index.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Continue the review with product and quality pages<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/corrosion-resistant-working-condition\/\">Materials & Corrosion<small>Return to the materials & corrosion hub.<\/small><\/a><a class=\"rv-link\" href=\"\/duplex-stainless-steel-valves\/\">Duplex Stainless Steel Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/nace-valves\/\">NACE \/ Sour Service Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/low-temperature-steel-valves\/\">Low Temperature Valves<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/industrial-valves\/\">Industrial Valves<small>Compare the main product families.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Slurry Service Valves<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Slurry Service Valves?<\/summary><p>Start with particle size, shape and hardness, solids concentration and velocity, hardfacing\/liner\/seat pairing, flush, purge and replaceable wear parts. Add the tag function, failure consequence, interfaces, standards, tests and turnover requirements.<\/p><\/details><details><summary>Which valve type is best for Slurry Service Valves?<\/summary><p>The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Send the operating cases, not only a valve name<\/h2><p>Share fluid details, pressure-temperature and flow cases, piping interfaces, operation, standards, tests and documents. Raymon Valve can return a clarified route and open-point list.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Materials & Corrosion\",\"item\":\"https:\/\/raymonvalve.com\/corrosion-resistant-working-condition\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Slurry Service Valves\",\"item\":\"https:\/\/raymonvalve.com\/slurry-valves\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Slurry Service Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Start with particle size, shape and hardness, solids concentration and velocity, hardfacing\/liner\/seat pairing, flush, purge and replaceable wear parts. Add the tag function, failure consequence, interfaces, standards, tests and turnover requirements.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Slurry Service Valves?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The title does not determine one valve type. Isolation, regulation, non-return and protective duties use different constructions; the service envelope, leakage, pressure drop and maintenance plan decide the route.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Record the exact designation, part and project-approved edition, map its scope and add purchaser options or project supplements. An acronym alone does not prove complete compliance.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ask for records that apply to the supplied configuration and tag. Generic catalogs or unrelated certificates are supporting information, not order acceptance evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A preliminary route can be discussed, but final selection needs a complete datasheet and application review. Accept performance, certification or material claims only when order-specific evidence supports them.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u041e\u0431\u0437\u043e\u0440 \u043a\u043b\u0430\u043f\u0430\u043d\u043e\u0432 \u0434\u043b\u044f \u0430\u0431\u0440\u0430\u0437\u0438\u0432\u043d\u044b\u0445 \u0441\u0440\u0435\u0434: \u0434\u0430\u043d\u043d\u044b\u0435 \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438, \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f, \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u043f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b, \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438 \u0432\u0445\u043e\u0434\u043d\u044b\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u0437\u0430\u043f\u0440\u043e\u0441\u0430 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f \u043f\u0440\u0438 \u0432\u044b\u0431\u043e\u0440\u0435 \u043a\u043b\u0430\u043f\u0430\u043d\u043e\u0432 \u0434\u043b\u044f \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0435\u043a\u0442\u0430.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13662","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13662","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=13662"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13662\/revisions"}],"predecessor-version":[{"id":13938,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13662\/revisions\/13938"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=13662"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}