{"id":13728,"date":"2026-07-27T22:10:16","date_gmt":"2026-07-27T14:10:16","guid":{"rendered":"https:\/\/raymonvalve.com\/flow-control\/"},"modified":"2026-07-27T22:46:11","modified_gmt":"2026-07-27T14:46:11","slug":"flow-control","status":"publish","type":"page","link":"https:\/\/raymonvalve.com\/ru\/flow-control\/","title":{"rendered":"\u0420\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0430\u0441\u0445\u043e\u0434\u0430"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13728\" class=\"elementor elementor-13728 elementor-bc-flex-widget\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-137590d0 e-con-full e-flex e-con e-parent\" data-id=\"137590d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09aee7ca elementor-widget elementor-widget-html\" data-id=\"09aee7ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\n:root{--rv-navy:#0b1731;--rv-blue:#07549a;--rv-yellow:#f3cc18;--rv-ink:#17233a;--rv-muted:#5c6779;--rv-line:#dfe5ee;--rv-soft:#f4f7fb}.rv-mm{font-family:Arial,Helvetica,sans-serif;color:var(--rv-ink);line-height:1.7}.rv-mm *{box-sizing:border-box}.rv-mm a{text-decoration:none}.rv-wrap{width:min(1160px,calc(100% - 40px));margin:auto}.rv-hero{padding:86px 0 72px;background:linear-gradient(112deg,rgba(6,18,43,.98),rgba(7,65,125,.91));color:#fff}.rv-crumb{font-size:13px;color:#c9d5e8;margin-bottom:22px}.rv-crumb a{color:#fff}.rv-kicker{color:var(--rv-yellow);font-size:12px;font-weight:800;letter-spacing:.13em;text-transform:uppercase}.rv-hero h1{max-width:920px;font-size:clamp(36px,5vw,62px);line-height:1.08;margin:12px 0 20px;color:#fff}.rv-hero p{max-width:900px;font-size:18px;color:#e5edf7}.rv-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.rv-btn{display:inline-flex;padding:13px 22px;border-radius:5px;font-weight:800;font-size:14px}.rv-primary{background:var(--rv-yellow);color:var(--rv-navy)}.rv-ghost{border:1px solid #9fb2cd;color:#fff}.rv-section{padding:72px 0}.rv-soft{background:var(--rv-soft)}.rv-dark{background:var(--rv-navy);color:#fff}.rv-dark h2,.rv-dark h3{color:#fff}.rv-h2{font-size:clamp(28px,3.5vw,42px);line-height:1.2;margin:8px 0 16px;color:var(--rv-navy)}.rv-lead{max-width:900px;color:var(--rv-muted);font-size:17px}.rv-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:16px;margin-top:30px}.rv-card{background:#fff;border:1px solid var(--rv-line);border-radius:12px;padding:24px;box-shadow:0 8px 24px rgba(11,23,49,.05)}.rv-card b{display:block;color:var(--rv-blue);margin-bottom:8px}.rv-card p{margin:0;color:var(--rv-muted);font-size:14px}.rv-tablewrap{overflow-x:auto;margin-top:30px;border:1px solid var(--rv-line);border-radius:12px}.rv-table{width:100%;border-collapse:collapse;background:#fff;min-width:780px}.rv-table th{background:var(--rv-blue);color:#fff;text-align:left;padding:15px}.rv-table td{padding:15px;border-bottom:1px solid var(--rv-line);vertical-align:top}.rv-table tr:last-child td{border:0}.rv-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin-top:30px}.rv-step{padding:24px;border:1px solid #2b3c5c;border-radius:12px}.rv-step span{display:block;color:var(--rv-yellow);font-size:12px;font-weight:800;margin-bottom:8px}.rv-step p{color:#cbd5e5;margin:0;font-size:14px}.rv-note{padding:24px;border-left:5px solid var(--rv-yellow);background:#fff8d8;border-radius:8px;margin-top:28px}.rv-links{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:28px}.rv-link{display:block;border:1px solid var(--rv-line);background:#fff;border-radius:10px;padding:20px;color:var(--rv-navy);font-weight:800}.rv-link small{display:block;color:var(--rv-muted);font-weight:400;margin-top:5px}.rv-faq{margin-top:24px}.rv-faq details{border-bottom:1px solid var(--rv-line);padding:18px 4px}.rv-faq summary{cursor:pointer;font-weight:800;color:var(--rv-navy)}.rv-faq p{color:var(--rv-muted)}.rv-check{columns:2;column-gap:40px;margin-top:24px}.rv-check li{break-inside:avoid;margin:0 0 12px}.rv-cta{text-align:center}.rv-cta p{max-width:760px;margin:12px auto 26px;color:#cbd5e5}body .site-content>.ast-container{max-width:100%!important;padding:0!important}body #primary,body #main,body .entry-content{margin:0!important;padding:0!important}.entry-header{display:none!important}@media(max-width:900px){.rv-grid,.rv-steps{grid-template-columns:1fr 1fr}.rv-links{grid-template-columns:1fr 1fr}}@media(max-width:640px){.rv-wrap{width:min(100% - 28px,1160px)}.rv-hero{padding:60px 0}.rv-section{padding:52px 0}.rv-grid,.rv-steps,.rv-links{grid-template-columns:1fr}.rv-check{columns:1}}\n<\/style><main class=\"rv-mm\">\n<section class=\"rv-hero\"><div class=\"rv-wrap\"><div class=\"rv-crumb\"><a href=\"\/\">Home<\/a> \/ <a href=\"\/valve-solutions\/\">Solutions<\/a> \/ Flow Control<\/div><div class=\"rv-kicker\">Engineering solution<\/div><h1>Flow Control: Engineering Review Framework<\/h1><p>Flow Control requires a defined engineering problem, measurable acceptance criteria and traceable evidence. This page explains how Raymon Valve structures hydraulic and control-performance review, what project data controls the decision and which risks should be closed before manufacture or package release.<\/p><div class=\"rv-actions\"><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Send Application Data<\/a><a class=\"rv-btn rv-ghost\" href=\"#review\">Review the Framework<\/a><\/div><\/div><\/section>\n<section id=\"review\" class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Search intent and scope<\/div><h2 class=\"rv-h2\">Start with the engineering decision, not a catalog label<\/h2><p class=\"rv-lead\">The search intent behind flow control is practical: convert a process or procurement problem into an approved valve requirement and evidence plan. For engineers and buyers who need a defensible solution route rather than a generic product recommendation, the goal is a defensible decision trail rather than an unsupported product claim.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>01. Define the functional objective<\/b><p>Convert this subject into measurable requirements, review points and tag-linked evidence instead of leaving it as a brochure description.<\/p><\/div><div class=\"rv-card\"><b>02. Freeze boundary conditions<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><div class=\"rv-card\"><b>03. Compare feasible construction routes<\/b><p>Convert this subject into measurable requirements, review points and tag-linked evidence instead of leaving it as a brochure description.<\/p><\/div><div class=\"rv-card\"><b>04. Verify package performance and records<\/b><p>For this workstream, name the responsible discipline, freeze the inputs and agree how the supplier will prove the proposed route.<\/p><\/div><\/div><div class=\"rv-note\"><b>Boundary of this guide:<\/b> Service, jurisdiction, project specification and construction can change the result; verify current standards, calculations and supplier documents.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Decision matrix<\/div><h2 class=\"rv-h2\">Translate application data into a reviewable valve requirement<\/h2><p class=\"rv-lead\">A clear evidence route exposes scope gaps early and prevents a generic quotation from being mistaken for technical compliance.<\/p><div class=\"rv-tablewrap\"><table class=\"rv-table\"><thead><tr><th>Decision area<\/th><th>Engineering question<\/th><th>Required evidence<\/th><\/tr><\/thead><tbody><tr><td><b>Function and consequence<\/b><\/td><td>Separate isolation, regulation, non-return and protective functions for flow control; assign acceptance for each.<\/td><td>Datasheet function, line list and functional requirement approved by the responsible engineer<\/td><\/tr><tr><td><b>Process envelope<\/b><\/td><td>Quantify minimum, normal, maximum and upset flow and include every case that can control sizing, material or sealing.<\/td><td>Approved process cases, fluid-property source and assumptions register<\/td><\/tr><tr><td><b>Mechanical interface<\/b><\/td><td>Check the installed connection, flow direction, support loads, operator envelope and future removal path.<\/td><td>Piping isometric, interface dimensions and marked-up supplier drawing<\/td><\/tr><tr><td><b>Materials and sealing<\/b><\/td><td>Resolve corrosion, erosion, temperature, galling, permeation and external-leakage needs at component level.<\/td><td>Approved material list, welding\/heat-treatment route and seal qualification evidence<\/td><\/tr><tr><td><b>Operation and controls<\/b><\/td><td>State manual or automated duty, cycle rate, fail state, utility limits, travel time, feedback and interlocks.<\/td><td>Sizing calculation, control narrative, hook-up\/interface drawings and functional test<\/td><\/tr><tr><td><b>Quality evidence<\/b><\/td><td>Agree design review, NDE, pressure and leakage tests, special qualifications, intervention points and final records.<\/td><td>Approved ITP, procedures, calibrated results and tag-linked manufacturing record book<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application risks<\/div><h2 class=\"rv-h2\">Risks the proposal must address explicitly<\/h2><p class=\"rv-lead\">Screen the actual service against these failure mechanisms and state how the selected route prevents, detects or tolerates them.<\/p><div class=\"rv-grid\"><div class=\"rv-card\"><b>Sizing from pipe diameter<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><div class=\"rv-card\"><b>Using only the normal case<\/b><p>Tie mitigation to the actual operating case and verify it through calculation, qualification, inspection or package-level testing.<\/p><\/div><div class=\"rv-card\"><b>Ignoring installed characteristic, cavitation or surge<\/b><p>Do not leave this as an assumption: assign a requirement, acceptance method, responsible reviewer and closeout document.<\/p><\/div><\/div><p class=\"rv-lead\" style=\"margin-top:28px\">Terms such as severe service, fire safe, low emission, non-slam or corrosion resistant need a stated standard, test, limit or application basis.<\/p><\/div><\/section>\n<section class=\"rv-section rv-dark\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Engineering workflow<\/div><h2 class=\"rv-h2\">Stage-gated review for a defensible technical decision<\/h2><div class=\"rv-steps\"><div class=\"rv-step\"><span>STEP 1<\/span><b>Define<\/b><p>Write a functional requirement for flow control that covers normal operation and credible failure states.<\/p><\/div><div class=\"rv-step\"><span>STEP 2<\/span><b>Characterize<\/b><p>Validate the process, mechanical and operational inputs, especially minimum, normal, maximum and upset flow.<\/p><\/div><div class=\"rv-step\"><span>STEP 3<\/span><b>Screen<\/b><p>Eliminate unsuitable constructions using the function, medium, envelope, interface and maintenance constraints.<\/p><\/div><div class=\"rv-step\"><span>STEP 4<\/span><b>Calculate<\/b><p>Test the proposed route against every controlling case with documented methods and conservative assumptions.<\/p><\/div><div class=\"rv-step\"><span>STEP 5<\/span><b>Verify<\/b><p>Resolve deviations and verify interfaces, acceptance methods and evidence before manufacturing release.<\/p><\/div><div class=\"rv-step\"><span>STEP 6<\/span><b>Release<\/b><p>Confirm manufacturing and documentation closeout so the delivered valve can be identified, installed and maintained correctly.<\/p><\/div><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">RFQ and review checklist<\/div><h2 class=\"rv-h2\">RFQ inputs that remove avoidable supplier assumptions<\/h2><p class=\"rv-lead\">A disciplined inquiry improves technical comparability, reveals exclusions and reduces changes after purchase order placement.<\/p><ul class=\"rv-check\"><li>Search question converted into a project requirement for Flow Control<\/li><li>System boundary, operating role and criticality classification<\/li><li>Minimum, normal, maximum and upset flow<\/li><li>Inlet\/outlet pressure and temperature<\/li><li>Minimum\/normal\/maximum process cases and all design transients<\/li><li>Process chemistry, solids data, velocity, cycling and abnormal contamination<\/li><li>Piping class, mating connection, bore, length, loads, access and removal clearance<\/li><li>Body, trim, seat, sealing, bolting, coating or lining materials<\/li><li>Actuator sizing cases, accessories, override, indication, interlocks and failure behavior<\/li><li>Document hierarchy, exact standard designations, editions and project supplements<\/li><li>Inspection methods, sampling, test configuration, instruments and acceptance limits<\/li><li>Inspection points, document index, certificates, spares and delivery requirements<\/li><\/ul><div class=\"rv-note\"><b>Evidence rule:<\/b> Marketing content can explain a route, but only controlled drawings, calculations, certificates, procedures and results can close an order requirement.<\/div><\/div><\/section>\n<section class=\"rv-section rv-soft\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Related engineering routes<\/div><h2 class=\"rv-h2\">Follow the internal route from application to inspection<\/h2><div class=\"rv-links\"><a class=\"rv-link\" href=\"\/valve-solutions\/\">Solutions<small>Return to the solutions hub.<\/small><\/a><a class=\"rv-link\" href=\"\/flow-characteristic-selection\/\">Flow Characteristic Selection<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/fugitive-emission-control\/\">Fugitive Emission Control<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/control-valve-sizing-guide\/\">Control Valve Sizing<small>Continue with a closely related engineering decision.<\/small><\/a><a class=\"rv-link\" href=\"\/control-valves\/\">Control Valves<small>Review the relevant product-family construction routes.<\/small><\/a><a class=\"rv-link\" href=\"\/valve-inspection\/\">Inspection & Evidence<small>Plan quality intervention and tag-level records.<\/small><\/a><\/div><\/div><\/section>\n<section class=\"rv-section\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">FAQ<\/div><h2 class=\"rv-h2\">Questions engineers and buyers ask about Flow Control<\/h2><div class=\"rv-faq\"><details><summary>What information is needed to evaluate Flow Control?<\/summary><p>Provide minimum, normal, maximum and upset flow, inlet\/outlet pressure and temperature, fluid properties and phase behavior, allowable noise, velocity and pressure drop together with the line class, installation, operating method, acceptance criteria and required records.<\/p><\/details><details><summary>Which valve type is best for Flow Control?<\/summary><p>No universal type is best. The defensible choice is the one whose construction, materials, operator and evidence meet the complete application without relying on hidden assumptions.<\/p><\/details><details><summary>How should standards be specified?<\/summary><p>Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.<\/p><\/details><details><summary>What evidence should a supplier provide?<\/summary><p>Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.<\/p><\/details><details><summary>Can Raymon Valve confirm suitability from a short inquiry?<\/summary><p>A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.<\/p><\/details><\/div><\/div><\/section>\n<section class=\"rv-section rv-dark rv-cta\"><div class=\"rv-wrap\"><div class=\"rv-kicker\">Application review<\/div><h2 class=\"rv-h2\">Give engineering enough information to challenge assumptions<\/h2><p>Attach the datasheet, line class and project requirements. We will separate confirmed inputs from assumptions and identify the checks needed for technical approval.<\/p><a class=\"rv-btn rv-primary\" href=\"\/contact\/\">Request Engineering Review<\/a><\/div><\/section>\n<script type=\"application\/ld+json\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/raymonvalve.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions\",\"item\":\"https:\/\/raymonvalve.com\/valve-solutions\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Flow Control\",\"item\":\"https:\/\/raymonvalve.com\/flow-control\/\"}]},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What information is needed to evaluate Flow Control?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Provide minimum, normal, maximum and upset flow, inlet\/outlet pressure and temperature, fluid properties and phase behavior, allowable noise, velocity and pressure drop together with the line class, installation, operating method, acceptance criteria and required records.\"}},{\"@type\":\"Question\",\"name\":\"Which valve type is best for Flow Control?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No universal type is best. The defensible choice is the one whose construction, materials, operator and evidence meet the complete application without relying on hidden assumptions.\"}},{\"@type\":\"Question\",\"name\":\"How should standards be specified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm the official document and contract edition, then state which requirement it controls. Resolve conflicts through the project precedence and deviation process.\"}},{\"@type\":\"Question\",\"name\":\"What evidence should a supplier provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Agree the tag-level package before manufacture. It may include drawings, calculations, material and welding records, NDE, pressure\/leakage results, functional tests, inspection release and manuals.\"}},{\"@type\":\"Question\",\"name\":\"Can Raymon Valve confirm suitability from a short inquiry?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A short inquiry can identify likely options and missing data. Technical approval should wait until the controlling cases, interfaces and acceptance evidence are agreed.\"}}]}]<\/script>\n<\/main>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u041e\u0431\u0437\u043e\u0440 \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0440\u0430\u0441\u0445\u043e\u0434\u0430: \u0434\u0430\u043d\u043d\u044b\u0435 \u043f\u043e \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438, \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f, \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b, \u043f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b, \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0438 \u0432\u0445\u043e\u0434\u043d\u044b\u0435 \u0434\u0430\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u0437\u0430\u043f\u0440\u043e\u0441\u0430 \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f (RFQ) \u0434\u043b\u044f \u0432\u044b\u0431\u043e\u0440\u0430 \u043a\u043b\u0430\u043f\u0430\u043d\u0430 \u043f\u043e\u0434 \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u044b\u0439 \u043f\u0440\u043e\u0435\u043a\u0442.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"full-width","ast-site-content-layout":"full-width","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13728","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13728","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=13728"}],"version-history":[{"count":2,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13728\/revisions"}],"predecessor-version":[{"id":14001,"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/pages\/13728\/revisions\/14001"}],"wp:attachment":[{"href":"https:\/\/raymonvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=13728"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}