Industrial valve product

Worm-Gear Wafer Butterfly Valve

Worm-Gear Wafer Butterfly Valve for project-defined compact quarter-turn isolation or regulation. Selection addresses compact installation between flanges with disc-clearance and gasket controls, materials, operation, testing and documented acceptance before quotation release.

Application-based selectionOrder-specific documentationInspection and test planning
Engineering scope

What controls a responsible Worm-Gear Wafer Butterfly Valve selection

A Worm-Gear Wafer Butterfly Valve is evaluated for compact quarter-turn isolation or regulation. A disc rotates within the body and piping bore. Offset geometry, seat construction, shaft support, flange interface and actuator torque determine sealing, wear and controllability.

The product name narrows the route but does not complete the specification. Resolve compact installation between flanges with disc-clearance and gasket controls together with the medium, operating cases, piping interface, maintenance and evidence.

Wafer

Compact installation between flanges with disc-clearance and gasket controls. Confirm flange type, inside diameter, gasket, bolt arrangement, pipe schedule and removal access.

Application envelope

Confirm every pressure, temperature, differential-pressure and cycling case for this Worm-Gear Wafer Butterfly Valve.

Installed interface

Verify ends, bore, flow direction, orientation, operator envelope, loads and maintenance access.

Order-specific boundary

Website content is not tag-level certification. Suitability and supplied scope are established only by the accepted quotation, datasheet and drawing.

Existing listing data

Published configuration data for Worm-Gear Wafer Butterfly Valve—confirmation required

The values below are transcribed from the previous public product listing so useful model information is not lost during the quality rebuild. They are not a universal available range, certificate or order commitment. Confirm every value in the accepted quotation, tag datasheet and approved drawing.

Parameter Previous listing Required order check
Product type Not stated in the previous public listing. Confirm the exact model, construction and supplied configuration.
Nominal size / DN Not stated in the previous public listing. Confirm each ordered tag and available trim or bore combination.
Pressure rating PN10 / PN16 / Class 150 | Connection Type: Wafer Type | Body Materials: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel | Disc Materials: Ductile Iron, Stainless Steel 304, Stainless Steel 316, Bronze | Seat Materials: EPDM, NBR, PTFE, Viton (depending Confirm governing rating standard, class and temperature basis.
Temperature Not stated in the previous public listing. Confirm design, operating, startup and upset metal temperatures.
End connection Not stated in the previous public listing. Confirm standard, facing, schedule, bore and mating interface.
Flow coefficient / characteristic Not stated in the previous public listing. Confirm calculated cases, trim, travel and installed behavior.
Body / bonnet material Not stated in the previous public listing. Confirm component grade, product form, heat treatment and records.
Trim / closure material Not stated in the previous public listing. Confirm every wetted component, hardness, coating and pairing.
Seat / seal material Not stated in the previous public listing. Confirm compatibility, leakage criterion and pressure-temperature limit.
Operation / actuator Worm Gear Operation | Applicable Media: Water, Air, General Service Fluids, Mildly Corrosive Media | Temperature Range: Depends on seat material and working condition | Applicable Standards: ANSI, DIN, JIS, BS, GB | Materials & Construction | The worm gear waf Confirm worst-case load, fail state, utilities, speed and accessories.
Leakage basis Not stated in the previous public listing. Confirm standard, edition, test direction, medium and measurable acceptance.

Evidence boundary: where the previous listing was incomplete or awkwardly translated, this page does not guess a value. Raymon Valve should replace provisional web data with the controlled product datasheet when it is available.

Specification workflow

Build the technical requirement before approving the model

Record the question, accepted answer and proof so the Worm-Gear Wafer Butterfly Valve proposal can be audited across disciplines.

Review area Engineering question Required record
Disc and seat geometry Concentric, double-offset or triple-offset construction must match shutoff and temperature duty. Name the controlling document, responsible reviewer and inspection or calculation record.
Piping interface Wafer, lug, flanged or welded bodies require compatible flange dimensions, gaskets and disc clearance. Resolve the open point before release and retain tag-specific evidence in the final dossier.
Torque basis Seating, bearing, packing and hydrodynamic torque must be checked at every operating case. Make this requirement auditable through the order datasheet, design review and inspection plan.
Flow duty On-off, throttling, minimum opening and velocity limits should be stated. Name the controlling document, responsible reviewer and inspection or calculation record.
Wafer Confirm flange type, inside diameter, gasket, bolt arrangement, pipe schedule and removal access. Make this requirement auditable through the order datasheet, design review and inspection plan.

A standard title alone is not acceptance. Map its scope, edition and required evidence to the valve tag.

Application boundaries

Failure exposures behind the nominal configuration

Check disc clearance, installation orientation and transient loads; a nominal flange fit does not prove that the disc can open safely. Installed behavior can be governed by flow dynamics, deposits, operating frequency, maintenance access and the response to abnormal conditions.

Complete medium composition, pressure, temperature and flow cases for the Worm-Gear Wafer Butterfly Valve
Valve role, operating cycles, permitted leakage, safe state and consequence of failure
Pressure class, size, end connection, face-to-face and piping-interface requirements
Corrosion and wear basis with exact body, trim, sealing, bolting, overlay, lining or coating materials
Operator and actuator load basis, safety factor, override, signals, switches, interlocks and package test
Applicable standards, pressure tests, special tests, inspection points and final documents
Evidence and quality

Define the manufacturing and test proof before release

Evidence should identify the supplied configuration, revision, heat or lot and applicable test procedure. Use the valve standards guide to separate product, rating, dimensional, end-connection and test scope.

Design basis

Approved datasheet, drawing, bill of materials, rating basis and documented deviations.

Material identity

Component certificates, heat or lot traceability, heat treatment, hardness and required PMI or NDE.

Inspection and tests

Hold/witness records, material/NDE/pressure/leakage/functional results and nonconformance closure.

A wafer body may not provide independent downstream isolation; piping procedures must reflect the design.

Qualification, testing and material suitability are conditional on the approved scope and supplied records for the actual configuration.

RFQ checklist

RFQ inputs that remove avoidable assumptions

Send tag identity, quantity, fluid, all design and operating cases, line interface, function, flow data, materials, operation, testing, inspection and turnover scope.

For a Worm-Gear Wafer Butterfly Valve, also highlight compact installation between flanges with disc-clearance and gasket controls. List unresolved assumptions as deviations instead of embedding them silently in the offer.

Send the service cases for engineering review

Send the valve list and project requirements. Raymon Valve will identify missing inputs, clarify construction and return an order-specific quotation basis.

Task-specific answer

Convert Worm-Gear Wafer Butterfly Valve from a broad request into an auditable engineering decision

This section addresses the decision a visitor is likely trying to complete—not merely the meaning of the page title. Use it to identify required inputs, compare the proposal and specify the record that will prove acceptance.

Decision What to do Evidence to retain
Problem statement For Worm-Gear Wafer Butterfly Valve, define the required system outcome, failure consequence and measurable acceptance before choosing hardware. Functional requirement
Feasible routes Compare at least the practical construction, material, sealing and actuation alternatives, including reasons for rejection. Option and trade-off matrix
Boundary conditions Check every normal, transient, startup, shutdown, maintenance and utility-loss case that can change the solution. Approved application data
Validation Connect each claimed benefit to a calculation, drawing, qualification, inspection or package-level test that applies to the order. Verification and evidence plan
Decision boundary: This guidance supports screening and RFQ preparation. Final suitability, compliance and supplied scope require the actual application data, governing jurisdiction, contract documents, approved supplier submittals and tag-linked records.

Content responsibility & evidence

How this Worm-Gear Wafer Butterfly Valve guide should be used

PublisherRaymon Valve technical content team
PurposeEngineering screening, specification and RFQ preparation
Content update29 July 2026
Verification levelTopic scope, search intent and evidence boundaries checked

This page does not claim that a named person, certificate, qualification, installed project or performance result applies to a future order. Product compliance is confirmed only when the accepted quotation, approved drawing, procedures and final manufacturing/test records identify the supplied configuration.

Technical requirements and standards can change. Verify the official source, contract edition, project precedence and purchaser options. See our technical content review and evidence policy, company information, inspection approach or submit a correction or application question.

FAQ

Worm-Gear Wafer Butterfly Valve questions

What information is required to select a Worm-Gear Wafer Butterfly Valve?

Provide the medium and composition, all pressure and temperature cases, nominal size, flow or differential pressure where relevant, required function, end connections, materials, shutoff criterion, operation, standards, inspection and documentation. For this configuration, the review must specifically address compact installation between flanges with disc-clearance and gasket controls.

Which standards apply to a Worm-Gear Wafer Butterfly Valve?

The answer depends on the product construction, project jurisdiction and purchaser specification. A product standard may cover design scope while separate standards govern pressure-temperature rating, dimensions, ends, pressure testing, fire safety, emissions or materials. A wafer body may not provide independent downstream isolation; piping procedures must reflect the design.

How should Worm-Gear Wafer Butterfly Valve pressure and leakage testing be specified?

Separate pressure-boundary, closure, functional and any special testing. Record the procedure, edition, duration, allowable leakage, intervention point and final evidence.

Can a Worm-Gear Wafer Butterfly Valve be supplied with an actuator?

Where automation is feasible, size from the worst-case valve torque or thrust curve, project margin, fail action, travel time, minimum utility, duty, controls, mounting and package test.

When should a Worm-Gear Wafer Butterfly Valve not be selected?

Do not select it when its qualified construction cannot satisfy the process, shutoff, materials, dynamics, maintenance or documentation requirements. Check disc clearance, installation orientation and transient loads; a nominal flange fit does not prove that the disc can open safely. The alternative should be chosen only after comparing the complete service duty.

en_USEnglish