Home / Resources / Valve Type Codes and Datasheet Identification
Codes decoded only in their documented system

Valve Type and Code Identification: How to Avoid Specification Errors

A valve code is meaningful only inside the coding system that created it. Manufacturer model strings, piping-class item codes, equipment tags, Chinese type-designation conventions and ERP stock numbers can use the same letters or digits differently. Decoding by guesswork can lead to the wrong pressure class, materials, trim, ends or actuator. The safe method is to preserve the original code, identify its issuer and revision, obtain the legend, then verify every decoded attribute against nameplate, datasheet and drawing evidence.

Issuer and legendTag vs modelDecoded attributesPhysical verification
Technical scope

Identify what kind of code you are reading

Equipment tag

A project tag identifies functional location; it usually does not fully encode the manufacturer construction.

Manufacturer model

A proprietary model may encode series, size, class, ends, materials or options under a specific catalog revision.

Piping item code

An EPC or owner code links a component to a controlled piping class and commodity description.

National designation system

A structured convention can describe attributes, but applicability and symbol meanings depend on the controlled standard/edition.

Serial and heat numbers

Serials trace an assembled valve; heat numbers trace material. They should not be substituted for product model identity.

Warehouse/ERP code

A stock number supports logistics and may omit engineering details needed for replacement or service review.

Evidence matrix

Cross-check every code against independent evidence

Data fieldPossible sourceVerification evidenceCommon error
Valve function/typeTag description, model legend or datasheet.P&ID duty, approved datasheet and section drawing.Assuming a letter has the same meaning across manufacturers.
Nominal size and boreModel string, nameplate or piping item description.End dimensions, bore drawing and pipeline size/schedule.Confusing nominal size with actual bore or port configuration.
Rating or pressure classNameplate/model/piping class.Applicable rating standard, material group and design temperature.Treating PN/Class digits as a fixed allowable pressure.
End connectionModel option or commodity code.Approved flange/weld/thread standard and detailed drawing.Ignoring flange series, facing, schedule or preparation.
Body/trim/seal materialsModel suffix or trim number.Bill of materials, certificates and component traceability.Using a trim number without the issuer's edition-specific table.
Actuation/optionsModel suffix, actuator tag or package code.Valve-actuator data, fail action, accessories and interface drawing.Ordering the valve model without the required package options.
Engineering evidence

A reliable replacement identification package

Photographs

Capture full valve, nameplate, body markings, ends, operator and orientation.

Original documents

Locate datasheet, purchase order, drawing, manual and model legend.

Measured interfaces

Verify face-to-face, flanges/weld ends, bore, stem and actuator envelope.

Service definition

Confirm fluid, pressure-temperature cases, direction, function and cycles.

Decoded matrix

List each symbol, proposed meaning, source and confidence or open question.

Supplier confirmation

Require a proposed datasheet and deviations rather than ordering from code alone.

Technical boundaries

Claims and shortcuts this page does not support

There is no universal valve-code decoder

Identical characters may carry different meanings in national, project and proprietary systems.

A model number is revision-dependent

Catalog options and symbol meanings can change; preserve manufacturer and document revision.

Decoded text does not prove delivered construction

Nameplate, drawing, bill of materials, certificates and inspection must close the identity chain.

Controlled workflow

From requirement to auditable evidence

1. Capture the code exactlyRetain punctuation, spacing, nameplate layout and surrounding markings.
2. Identify issuer and code familyDetermine whether it is a tag, model, commodity, standard or logistics number.
3. Obtain the controlled legendUse the correct manufacturer/project/standard document and revision.
4. Decode with uncertainty visibleMap symbols and mark unknown or conflicting attributes explicitly.
5. Verify physical and service dataCompare dimensions, materials, duty and operator with drawings and records.
6. Issue replacement specificationState complete requirements independently of the legacy code.
Project checklist

Information and records to define

Exact code and high-resolution nameplate/body-marking images
Manufacturer, project/owner and approximate supply date
Code-system legend and revision
Original datasheet, drawing, PO and manual
Valve function, fluid and operating conditions
Size/bore, rating, ends and face-to-face measurements
Materials, trim, seats, packing and bolting
Actuator/accessories, deviations and approved replacement sheet
Technical authority and scope

How this resource should be used

Primary search intent

Troubleshooting and replacement guidance for users trying to decode a valve model, tag, trim or type code without introducing false universal meanings.

Technical content owner

Raymon Valve technical content team. Final project decisions require the controlled documents and responsible engineer or quality reviewer.

Standards boundary

Code meanings must come from the controlled issuer document and edition. This page intentionally provides no universal symbol table because applying one system's legend to another can create unsafe procurement errors.

Review status

Technical scope reviewed 27 July 2026. Editions, procedures, acceptance criteria and product evidence must be reconfirmed before order.

Frequently asked questions

Valve Type Codes and Datasheet Identification FAQ

Is there a universal industrial valve coding system?

No. Standards, manufacturers, owners, EPCs and ERP systems use different schemes. First identify the code owner and correct legend.

What is the difference between a valve tag and model number?

A tag identifies the valve's project/system location and duty; a manufacturer model identifies a product configuration. Either may reference other documents and neither should be assumed to contain every attribute.

Can a trim number identify all internal materials?

Only when used with the correct issuer's controlled trim table and edition. Verify the bill of materials because seats, stem, closure and overlays may need more detail.

How should an obsolete valve be replaced when the code is unclear?

Reconstruct the requirement from nameplate, drawings, measured interfaces, service conditions and function, then obtain an approved replacement datasheet and deviation review.

Technical evidence review

Send the requirement and the evidence you need to verify

We will identify the applicable scope, missing records and approval path without inventing compliance claims.

en_USEnglish