Industrial valve types · Functions and selection
The 10 types of valves covered here are gate, globe, ball, butterfly, check, plug, diaphragm, needle, pinch and pressure relief valves. Their main duties are isolation, regulation, backflow prevention and overpressure protection. Choosing the wrong construction can affect shut-off, flow stability, operating load and maintenance. Use the comparisons below to identify candidate valve families and the data needed for an RFQ. Final selection depends on the medium, pressure-temperature cases, flow requirements, materials, sealing and installation constraints.
In this guide

What Are the 10 Common Types of Valves?
These ten common names describe construction or function; they are a practical overview, not a complete set of mutually exclusive categories. Each row identifies a family. The selected model’s materials, geometry, seals and ratings determine its actual capabilities.
On smaller screens, scroll this table horizontally to view every column.
| Valve type | Operating principle | Main duty | Example application | Key selection question |
|---|---|---|---|---|
| Gate | Gate moves into or out of the flow path | Isolation | Process and utility lines | Can the construction meet shut-off, differential-pressure and solids requirements? |
| Globe | Disc or plug moves toward a seat | Throttling and isolation | Steam, cooling water and process lines | Are pressure loss, trim loading and flow direction acceptable? |
| Ball | Ported ball rotates between open and closed | Isolation; characterized designs can regulate | Process and pipeline isolation | Are seat design, cavity behavior and operating torque suitable? |
| Butterfly | Disc rotates within the bore | Isolation; suitable designs can regulate | Water headers and process piping | Are disc clearance, seat limits and torque confirmed? |
| Check | Flow and differential pressure move a closure element | Reverse-flow prevention | Pump discharge and utility systems | Will it remain stable at operating flow and close appropriately during a transient? |
| Plug | Ported plug rotates within the body | Isolation or diversion; some designs regulate | Chemical transfer and multiport systems | Are sealing method, port arrangement and torque suitable? |
| Diaphragm | Flexible diaphragm closes against a weir or flow passage | Isolation; suitable designs can regulate | Chemical dosing and hygienic systems | Are diaphragm, body and cleaning conditions compatible? |
| Needle | Tapered stem adjusts a small opening | Fine flow adjustment; some designs isolate | Instrumentation and sampling | Does the stem and orifice provide the required controllability? |
| Pinch | Flexible sleeve is compressed | Isolation or regulation of suitable media | Slurry and solids-bearing lines | Can the sleeve withstand chemistry, pressure, wear and cycling? |
| Pressure relief | Self-actuated device opens in response to pressure | Overpressure protection | Protected vessels and piping systems | Are the relieving scenario, capacity and discharge conditions established? |
Use this table to identify candidate families, then review the corresponding product data. A familiar valve name does not establish suitability for a particular line. Explore the industrial valve product range for the next product review.
Choose the Required Valve Function First
Isolation and shut-off: Define the required closed-state leakage, sealing direction, operating frequency and differential pressure. Gate, ball, butterfly, plug and other constructions can be candidates, depending on service.
Throttling and regulation: Define minimum, normal and maximum flow cases together with inlet and outlet pressure. The valve must provide usable control without unacceptable vibration, noise, erosion or fluid-phase effects.
Backflow prevention: A check valve must respond to changing flow. Pipe size alone does not establish stable opening or suitable closing behavior.
Overpressure protection: A pressure relief device serves a protective function. Its selection starts with the protected equipment and credible relieving scenarios.
For a fuller functional specification, use the valve function guide. This article focuses on the construction families that may fulfill those duties.
10 Types of Valves and Their Applications
1. Gate Valve
A gate valve isolates flow by moving a gate across the passage. When fully open, the closure element is withdrawn from the main flow path. Wedge, parallel-slide, slab and knife-gate constructions have different sealing and service characteristics.
Gate valves are commonly considered for process and utility isolation where continuous modulation is unnecessary. Allow space for the stem and operator, and check access for maintenance.
A conventional isolation gate valve should not be assumed suitable for sustained throttling. Partial opening can expose seating areas and the gate to concentrated flow and vibration. Likewise, a standard wedge gate is not interchangeable with a purpose-designed solids-handling valve.
RFQ focus: Gate construction, seating direction, maximum operating differential pressure, solids, leakage acceptance and available operating thrust.
2. Globe Valve
A globe valve moves a disc or plug toward a seat to change the flow opening. Body patterns include straight, angle and Y-pattern arrangements. The internal flow path and trim influence pressure loss and operating forces.
Globe constructions are candidates for manual throttling, isolation and engineered control duties in suitable steam, water and process services. A hand-operated globe valve and an automatic globe control-valve assembly have different specification requirements.
Review the proposed flow direction and trim limits. High differential pressure can require assessment of cavitation, flashing, noise, vibration and actuator thrust; the body pattern alone does not resolve these risks.
RFQ focus: Flow cases, inlet/outlet pressure, temperature, required shut-off, flow direction and manual or automatic operation.
3. Ball Valve
A ball valve rotates a ported ball, commonly through a quarter turn, to align or block the passage. Floating and trunnion-mounted arrangements support the ball differently; full-bore and reduced-bore designs also have different interfaces and flow characteristics.
Ball valves are widely considered for process isolation and automated on/off duties. A full-bore construction may be relevant where an unobstructed passage is required, but pigging compatibility needs confirmation of the complete geometry.
Do not assume an ordinary on/off ball valve is suitable for continuous regulation. Characterized-port and other engineered control designs require their own sizing review. Trapped liquid, seat direction and cavity-pressure behavior also need attention in applicable services.
RFQ focus: Bore, ball support, seat system, cavity-pressure provisions, differential pressure and operating torque. The ball valve selection guide provides a more detailed review route.
4. Butterfly Valve
A butterfly valve uses a rotating disc within the bore. Concentric, double-offset and triple-offset constructions differ in how the disc moves relative to the seat and how sealing contact is established.
Butterfly valves are often screened for water systems, large piping and process duties where installation space and operating arrangement matter. Suitable constructions can provide isolation or modulation.
The disc remains in the passage when open, so verify clearance against adjacent piping, lined components and equipment. Seat material, differential pressure and disc position affect suitability and operating torque. A larger nominal size does not automatically mean adequate control performance.
RFQ focus: Offset construction, body/end style, seat material, mating dimensions, disc clearance and pressure-dependent torque.
Compare butterfly valve configurations after defining the offset construction, seat system and installation constraints.

5. Check Valve
A check valve allows forward flow and closes to oppose reverse flow without a separate operating command. Swing, lift, dual-plate, ball and axial/nozzle mechanisms have different travel, opening forces and dynamic behavior.
Check valves are used in pump discharge, compressor and utility systems where reverse flow must be limited. Installation orientation and the manufacturer’s minimum-flow guidance are important screening inputs.
An oversized valve can operate unstably at low flow. Closing performance also depends on how quickly the system decelerates and reverses; a “non-slam” description does not establish the complete system response.
Screening example: A check valve selected to match a large pipe may chatter during low-demand operation because flow is insufficient to hold its closure element steadily open. Compare the minimum operating flow with the supplier’s stable-opening guidance, check orientation and obtain the relevant pressure-loss and dynamic information before changing size or mechanism. This is a hypothetical review scenario, not a diagnosed installation.
RFQ focus: Minimum/normal/maximum flow, orientation, allowable pressure loss, pump stopping behavior and available transient information.
Compare industrial check valve options against the flow range, orientation and system stopping behavior.
6. Plug Valve
A plug valve rotates a ported plug to open, close or redirect the passage. Lubricated, sleeved and lined designs use different sealing arrangements. Multiport configurations can connect different flow routes.
Plug valves may be considered for process isolation, chemical transfer and diversion. A lined or sleeved construction must be reviewed against the actual medium and service envelope.
For lubricated designs, confirm lubricant compatibility and replenishment requirements. For multiport valves, define the port diagram and every transition state: the final handle position alone does not explain which passages may connect during movement.
RFQ focus: Lubricated or non-lubricated construction, lining/sleeve material, port logic, differential pressure and torque.
7. Diaphragm Valve
A diaphragm valve closes a passage by flexing a diaphragm against a weir or through a straight-through body arrangement. The diaphragm forms a barrier between the process fluid and operating mechanism. The wetted body and diaphragm require separate compatibility review.
Depending on construction, applications include chemical handling, water treatment and hygienic processing. Hygienic suitability requires an appropriate body geometry, materials, surface condition and installation; it is not established by the word “diaphragm.”
Temperature, chemical exposure, cleaning cycles and repeated flexing affect diaphragm selection. A diaphragm actuator fitted to a globe valve is a different arrangement from this valve family.
RFQ focus: Diaphragm material, body/lining, fluid concentration, cleaning or sterilization conditions, pressure-temperature envelope and operating frequency.
8. Needle Valve
A needle valve uses a tapered stem and relatively small seat opening to make incremental flow adjustments. Stem-tip, orifice and bonnet designs vary, including versions intended for shut-off, regulation or metering.
Needle valves are commonly screened for instrumentation, sampling, purge and small-flow duties. Select the flow coefficient and adjustment characteristics against the required flow range rather than the tubing connection alone.
Fine adjustment does not make a needle valve a general replacement for a process control valve. Solids can obstruct small passages, and shut-off performance must be confirmed for the selected stem and seat.
RFQ focus: Flow range, pressure differential, cleanliness, stem-tip design, connection, leakage requirement and required adjustment resolution.
9. Pinch Valve
A pinch valve compresses a flexible sleeve to reduce or close the passage. In common full-sleeve designs, the sleeve separates the fluid from the closing mechanism.
Suitable pinch constructions are candidates for slurry, powders in appropriate conveying systems and other solids-bearing services. The flexible passage can be useful where rigid trim would face obstruction or abrasive exposure.
Sleeve selection governs the review. Chemical attack, particle shape, velocity, temperature, vacuum and repeated deformation can affect performance. Regulation near closure may concentrate wear, so a slurry-control proposal needs operating cases and the supplier’s sleeve guidance.
RFQ focus: Solids concentration, particle size and hardness, chemistry, flow/pressure cases, vacuum conditions, actuation method and sleeve replacement access.

10. Pressure Relief Valve
A pressure relief valve opens automatically in response to pressure to discharge fluid from a protected system. Direct spring-loaded and pilot-operated constructions require different application checks.
Selection begins with the credible overpressure scenarios, protected equipment, set pressure and required relieving capacity. Fluid properties at relieving conditions, inlet losses and discharge-system backpressure must be assessed by the responsible engineer.
Terminology matters. “Safety valve,” “relief valve” and “safety relief valve” have definitions under applicable codes and practices; they should not be treated as universally interchangeable labels. A pressure-reducing valve regulates downstream pressure and does not automatically fulfill an independent overpressure-protection requirement.
RFQ focus: Governing protection basis, relieving scenarios, set pressure, required capacity, relieving fluid conditions, backpressure and required certification/documentation.
The governing protection code and contract edition must be confirmed for the protected system. Where the ASME BPVC framework applies, Section XIII provides overpressure-protection rules; its public scope page is listed in the references. This does not establish the suitability or certification of an offered valve.
How Do Control Valves and Actuated Valves Fit Into the List?
Valve names can describe different attributes. A globe valve can be manually operated or form part of an automatic control assembly. A ball valve can provide on/off isolation or use a characterized trim for modulation.
On smaller screens, scroll this table horizontally to view every column.
| Naming basis | Examples | What it tells the buyer |
|---|---|---|
| Closure construction | Ball, globe, butterfly, diaphragm | How the flow passage changes |
| Function | Isolation, control, non-return, pressure relief | What the valve must accomplish |
| Drive method | Manual, pneumatic, electric, hydraulic | How operating force or motion is supplied |
| Service/design feature | Lined, cryogenic, metal-seated | A further requirement that needs defined limits |
A control valve is selected as part of a control function, with the valve, actuator and relevant accessories evaluated together. “Actuated valve” describes the operating arrangement; an actuator does not change the underlying ball, gate or butterfly construction.
For modulation duties, review control valve assemblies against the complete flow cases and control requirements.
For automatic operation, request valve torque or thrust for the actual seat system and maximum differential pressure, then compare it with actuator output at the minimum available utility. Include operating time, frequency, ambient conditions, accessories, fail action and the agreed sizing-margin basis. Check allowable stem, shaft and mounting loads as well as available actuator output; nominal valve size alone cannot establish a suitable package.
Screening example: A pneumatic package may stroke correctly during an unloaded bench check yet fail to complete travel under the line differential pressure. The review must compare the required valve load with output across the stroke at minimum supply, including the spring-driven stroke where applicable. Confirm the load basis, utility conditions and functional-test scope before approving the assembly; do not solve an unverified load problem by simply choosing a larger actuator.

How to Shortlist a Valve for Your Application
Define the Medium and Operating Cases
Record composition, phase, concentration, solids and contamination. Include startup, shutdown, cleaning and upset conditions when they can change selection. For gas and liquid flow calculations, identify units and whether pressures are absolute or gauge.
Nominal size describes the connection, not the operating flow capacity. Cv and Kv are flow coefficients; the supplier’s published value must be understood at its stated test basis and valve opening. Request the units, fluid properties, flow cases, inlet/outlet pressures and predicted operating positions. A full-open coefficient does not establish controllability at partial travel, and a steady-flow capacity check does not demonstrate acceptable check-valve closing dynamics or system surge response.
Check Pressure, Temperature, Flow and Differential Pressure
Separate normal operation from design conditions and specify credible pressure-temperature combinations. Under the applicable rating system, pressure class depends on material group and temperature; Class 150, 300 or 600 is not a fixed pressure value. Review the body, bonnet or cover, bolting and trim together with seat, packing, gasket, lining or sleeve limits. Minimum temperature and thermal cycling can change material and sealing requirements even when the normal operating point appears acceptable.
Where ASME B16.34 applies, its scope includes valve pressure-temperature ratings and construction requirements. Confirm the selected material, product design and contract edition rather than transferring a rating from another construction. The official listing identifies the standard’s scope; it does not confirm the rating or compliance of a particular offered valve.
Review Materials, Seats and Leakage Requirements
Review the body, trim, stem, seats, packing and gaskets separately. For corrosive or mixed service, supply composition, concentration, pH and relevant contaminants such as chlorides or H₂S, together with temperature, pressure, flow, solids, cleaning media and shutdown exposure. These inputs help distinguish chemical attack, localized corrosion and erosion from seal swelling, permeation or mechanical wear; a body alloy name alone cannot resolve them.
Seats and trim govern closure contact and wear, while stem packing controls leakage along the stem and gaskets seal stationary joints. Material choice, contact load and friction also affect operating torque or thrust. Define allowable seat leakage separately from external leakage, including test conditions and acceptance criteria. Fire-safe or fugitive-emission requirements need applicable qualification evidence for the proposed configuration rather than inference from a seal material name.
Screening example: A metallic body may meet its pressure-temperature rating while a proposed soft seat does not cover the specified hot operating case or cleaning cycle. The body rating and seat limit answer different questions. Check the exact seat compound, temperature-pressure limits, fluid exposure and cycling requirements; request a documented alternative where the proposed sealing system falls outside its confirmed envelope.
Confirm Connections, Operation and Installation Constraints
Confirm the end-connection standard, flange facing or weld-end details, face-to-face dimension and mating equipment. A nominal flange-size match does not prove disc clearance, gasket compatibility or installation access. Check the proposed flow direction, support requirements, operator envelope and removal path. Record deviations on the supplier drawing before approving the configuration.

Which Service Conditions Change the Valve Shortlist?
Use this matrix to narrow the review, not to approve a construction. A candidate remains provisional until the supplier identifies the offered design, its limits and any deviations against the datasheet.
On smaller screens, scroll this table horizontally to view every column.
| Required duty / condition | Candidates to compare | What prevents a simple choice? | Evidence to request |
|---|---|---|---|
| Clean-fluid isolation; frequent operation | Ball, butterfly or plug; compare gate where operating speed permits | Required leakage, available space, pressure loss and torque can favor different designs | Seat-direction statement, rating data, dimensions and operating-load basis |
| Continuous flow regulation | Globe control or suitable characterized rotary construction | A nominal pipe-size match does not establish controllable opening across the flow range | Sizing report with process cases, predicted opening, pressure-drop risks and shut-off requirement |
| Solids-bearing isolation or regulation | Qualified pinch, diaphragm or solids-handling gate construction | Particle characteristics and differential pressure can exclude an otherwise familiar design | Solids data, wetted-material limits, wear provisions and maintenance requirements |
| Pump discharge / reverse-flow prevention | Check mechanisms appropriate to orientation and operating flow | A low-loss or non-slam label does not resolve the system stopping transient | Pressure-loss data, stable-flow guidance and applicable dynamic response information |
| Overpressure protection | Relief-device construction under the governing protection basis | Set pressure alone does not establish relieving capacity or acceptable backpressure | Relieving-case calculation, device capacity basis and required certification scope |
Example: One Water System, Three Different Duties
Illustrative assumptions: Clean water, ambient service, pressure and flow data still to be confirmed. This is a screening exercise, not an installed project.
A branch isolation point may start with ball, butterfly or gate candidates. A separate continuously regulated branch needs a suitable control construction and sizing cases. A pump discharge requires a check-valve review of operating flow and stopping behavior. These locations can share the same nominal pipe size while requiring different valve functions and acceptance evidence.
Next action: Give each tag its own duty and operating cases before asking suppliers to standardize the valve family or actuator.
What Information Should You Include in a Valve RFQ?
Use the following checklist to make supplier offers comparable. Mark missing information as an open item rather than leaving suppliers to assume it.
- Valve tag, quantity and required function.
- Medium, composition, phase, concentration and solids.
- Operating and design pressure/temperature, including relevant abnormal cases.
- Minimum, normal and maximum flow and associated inlet/outlet pressure where relevant.
- Size, end connection, pressure rating and dimensional requirements.
- Body, trim, seat, packing, diaphragm or sleeve requirements as applicable.
- Required shut-off direction, allowable leakage and test acceptance basis.
- Operating frequency, speed, manual or powered operation and fail position.
- Special service requirements and applicable project specifications.
- Inspection scope, witness points, documentation and spare-parts requirements.
For check, control and pressure relief valves, include the family-specific dynamic, sizing or protection data described above. Ask suppliers to identify deviations and unresolved assumptions in their quotations.
Pressure testing is one part of verification. A shell test addresses the pressure boundary; a closure or seat test addresses shut-off under specified conditions. ISO 5208:2015 covers pressure testing of industrial metallic valves in conjunction with the applicable product requirements; its scope does not cover pressure-test safety. Define the project’s test procedures and acceptance criteria separately. Use the valve pressure testing resource to prepare the inspection questions.
A pressure-test pass does not demonstrate the absence of every internal defect or replace the specified NDT. Functional tests, fire-safe qualification, fugitive-emission tests and any specified cryogenic tests address separate requirements. PMI checks material identity within the chosen method’s capability; it does not replace material certificates, heat-treatment records or tag-to-heat traceability. Agree the required records, hold/witness points and acceptance criteria before placing the order.
What Evidence Should the Supplier Return?
Ask each bidder to respond by valve tag, using the same datasheet revision. Identify the offered configuration, exceptions, included tests, documents and accessories before comparing price. A general catalog or company certificate does not establish acceptance of the particular offered valve.
On smaller screens, scroll this table horizontally to view every column.
| Review item | Ask the supplier to identify | Buyer acceptance check |
|---|---|---|
| Construction and materials | Model/configuration, drawing, component materials and stated limits | Offered scope matches the tag and duty; substitutions are declared |
| Sizing and operation | Calculation inputs, valve loads, available utility and actuator output where applicable | Operating and fail-action cases are addressed without unsupported assumptions |
| Testing and inspection | Applicable procedures, acceptance criteria, witness points and required records | Each required test has a defined scope; one test is not treated as proof of another |
| Technical deviations | Unconfirmed fields, exclusions, alternatives and document deliverables | Resolve differences before comparing price or releasing the purchase order |
Keep a tag-level deviation list and close material substitutions, sizing assumptions, interfaces, test acceptance and document scope before purchase approval. Where required, define MTCs, traceability, inspection reports, qualification evidence, drawing revisions and third-party intervention in the order. Confirm what is included in the quotation, what is optional and which inputs remain unconfirmed.
Frequently Asked Questions
What are the 10 common types of valves?
Gate, globe, ball, butterfly, check, plug, diaphragm, needle, pinch and pressure relief valves are ten common families. The list combines practical construction names and familiar functional families; it is not an exhaustive classification.
Are there only 10 types of valves?
No. Additional families and many subtypes exist. Valves can also be grouped by function, motion, port arrangement, sealing design, actuation or service requirement.
What is the difference between valve type and valve function?
Type often identifies the construction, such as ball or butterfly. Function identifies the duty, such as isolation or modulation. Some constructions can fulfill several duties, but the offered design must be qualified for the intended operating cases.
Which valve types are used for isolation?
Gate, ball, butterfly and plug valves are common isolation candidates. Globe, diaphragm and pinch designs can also isolate suitable services. Compare the fluid, pressure-temperature envelope, shut-off requirement, operating frequency and installation constraints before choosing a construction.
Can a ball valve be used for flow control?
Some characterized and purpose-designed ball valves can modulate flow. A standard on/off ball valve should not be assumed suitable for continuous throttling. Confirm sizing, control characteristic, pressure drop, fluid-phase risks and supplier limits.
What is the difference between a pressure relief valve and a pressure-reducing valve?
A pressure-reducing valve regulates a lower downstream pressure. A pressure relief valve discharges fluid in response to pressure for a defined protective duty. A reducing valve does not automatically provide the required overpressure protection.
What information is needed to select an industrial valve?
Start with function, medium, operating/design pressure and temperature, relevant flow cases, size, class or PN and connection standard. Add component materials, sealing/leakage requirements, operation, installation constraints, tests and documents. Control, check and relief duties need their own sizing, dynamic or protection data; a product name or pipe size alone is insufficient.
Request a Valve Selection Review
Send the required function, medium, operating and design pressure/temperature, flow range where relevant, size, class or PN, connection and quantity. Add material/seat preferences, leakage requirements, actuation and inspection scope. Attach the datasheet, line class or marked-up P&ID when available, and mark unknown fields as “to be confirmed.”
Request Valve Selection Review →
Use the inquiry to request a candidate construction, a list of missing inputs and a quotation that identifies assumptions, exclusions and required documents. Final sizing, material suitability and acceptance require the confirmed datasheet and approved supplier submittals.
Technical References
These sources explain general principles. Product-specific limits and qualifications require the selected manufacturer’s documentation.
- Swagelok — Valve Selection Best Practices — Function-first selection and valve duty.
- GEMÜ — Diaphragm Valves — Diaphragm and wetted-body arrangement.
- Red Valve — Pinch Valve Sleeves — Sleeve construction and solids-handling context.
- Val-Matic — Dynamic Characteristics of Check Valves — Closing response and system deceleration; the paper does not replace a complete check-valve selection review.
- ASME — BPVC Section XIII: Rules for Overpressure Protection — Official scope information for an overpressure-protection code. The governing rules and contract edition depend on the protected system and project requirements; this reference does not establish product certification.
Publisher: Raymon Valve. Learn more about Raymon Valve.
Engineering note: This guide supports preliminary screening and RFQ preparation. The diagrams show general principles, and the water-system example uses only its stated assumptions. Final selection requires confirmed process cases, project specifications and approved supplier documentation.